Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
1968 East Main Street Rooftop Solar Site Plan - 2025-10-28
1033990 NEW PV SYSTEM DESIGN DESIGN ENGINEER VVYSSLING 61 MODULES - 27.450 kW DC, 23.180 kW AC SYSTEM SIZE v vcomSulTffm!A SEPIASHVILI RESIDENCE - 1966 EAST MAIN STREET, MOHEGAN LAKE, NY 10547 76 N. MEADOWBROOK DRIVE UT 84004 AERIAL MAP VICINITY MAP SHEET INDEXALPINE swyssling@ wysslingconsulting. com NTS NTS PV -1 COVER PAGE PV (201)874-3483 -2 SITE PLAN PV -3 PROPERTY PLAN PV -4 COA#0022571 SOLAR COMPANYICLIENT ATTACHMENT PLAN - ��- PV -5 ♦� -� MOUNTING DETAILS PV -5.1 MOUNTING DETAILS _ r'• ,wA artSTRING PLAN O EE 2 THREE LINE DIAGRAM `�. wd EE -3 /� r'°r I� �L—/,l ELECTRICAL NOTES EE -4 .-I LABELS EE -5 PLACARD PV -6 RIVERTOWN SOLAR LLC DESIGN NOTES 23 MAIN STREET �e `,SPECIFICATION SPEC SITE PHOTOS IRVINGTON, NY ' .•J' MNFire SHEETS Depanmem�• pn SCOPE OF WORK SEPIASHVILI j/corner car care .7 � - / SYSTEM SIZE: 27.450KW DC / 23.18OKW AC SYSTEM SIZE RESIDENCE PV MODULE: (61) TALESUN TM7G54M 450 1966 EAST MAIN STREET �% C) INVERTER: (61) ENPHASEIQBHC-72-M-US MOHEGAN LAKE, NY 10547 v��1 / whey Od COMBINER: (1) MINIMUM 200A LOAD CENTER AC DISCONNECT: COORDINATES: 41.319028,-73.857951 . (1) 200A FUSED AC DISCONNECT WITH 125A FUSES (1) 200A UNFUSED AC DISCONNECT (914) 814-0716 COVER PAGE 'i'`''>'_•�'c-'+ Q t aF - ! ROOF STORIES:2 • ROOF TYPE(S): COMP SHINGLE 8 ROLLED COMP MOUNTING(S) 8 RACKING(S): IRONRIDGE QUICKMOUNT HALO ULTRAGRIP WITH IRONRIDGE XR10 RAIL 8 IRONRIDGE FLAT ROOF ATTACHMENT (FIXED TILT LEGS) WITH IRONRIDGE XR10 GOVERNING CODES RAIL FLASHING: IRONRIDGE OF NEIV 2017 NATIONAL ELECTRIC CODE ULTRAGRIP FLASHING ROOF BEING REPLACED: YES ROOF E W CONDITION: POOR 2020 RESIDENTIAL CODE OF NEW YORK STATE (2018 INTERNATIONAL RESIDENTIAL CODE)ROOF HEIGHT: 25 FEET D 2020 FIRE CODE OF NEW YORK STATE 2020 FUEL GAS CODE OF NEW YORK STATE 2020 EXISTING BUILDING CODE OF NEW YORK STATE 2020 ENERGY CONSERVATION CODE OF NEW YORK STATE 2020 MECHANICAL CODE OF NEW YORK STATE 2020 PLUMBING CODE OF NEW YORK STATE ,�AA •V 092309 t�V AS ADOPTED BY ALDEN INCLUDING ANY AMENDMENTS INTERCONNECTION: LINE SIDE TAP OR ADDITIONAL LISTED REQUIREMENTS. MAIN SERVICE PANEL LOCATION: BASEMENT SSIONP�'0 DESIGNED IN ACCORDANCE WITH THE REQUIREMENTS OF CON EDISON UTILITY. MAIN SERVICE PANEL RATING: (E) 200A Wyss n Consulting, PLLC EQUIPMENT IS COMPATIBLE WITH ULUL7741, AND MAIN BREAKER RATING: (E) 200A UL1703 AS APPLICABLE 76NNea eek On°e Alpine Ur 840042703, OCPD: 125A FUSE N—York COA N D022571 Signed 11/3/2025 CONED METER NUMBER: A71B 11033990 DATE REVISION COMMENT DESIGN CRITERIA ARRAY TILT AZIMUTH ADDED FIRE SETBACKS 1 30° 312° OC SYSTEM SIZE: 27.45OkW WIND SPEED: 115 MPH 2 5° 222• 10/28/2025 B AND CHANGED GROUND SNOW LOAD: 40 PSF ATTACHMENT FOR ROOF 3 0° AC SYSTEM SIZE: 23.180kW ASCE: 7-16 222° 3 EXPOSURE CATEGORY: C 4 5° 42° AHJ: ALDEN BUILDING OCCUPANCY; R-3 UTILITY: CONED CONSTRUCTION TYPE: TYPE V -B DRAWN BY: AKM SPRINKLERS: NO INITIAL DESIGN DATE: 08/25/2025 REV: B PV -1 CONED METER NUMBER: A71B 11033990 SYSTEM INFORMATION MODULE (61) TALESUN TM7G54M 450 COUNT/TYPE PLUMBING VENT (TYP.) INVERTER (fit) ENPHASE IQBHC-72-M-US COUNTITYPE SATELLITE DISH MODULE ELECTRICAL MAST WEIGHT 54.01 LBS MODULE FIRECODE PATHWAY DIMENSIONS 67.60"x44.65" UNIT WEIGHT 5' OF ARRAY 2;57 PSF LEGEND �u efss> vn — a�T. ROOF VENT(TYP.) rAUESUNMGWLE PLUMBING VENT (TYP.) O AIC UNIT A/C SATELLITE DISH 4 ELECTRICAL MAST $ CHIMNEY Q FIRECODE PATHWAY 3UNP BREAKER ROOF # �u efss> vn — a�T. TILT rAUESUNMGWLE I AZIMUTH ErsNnsElceHcnM-us MODULE COUNT MIM1VAIIONG 1 2pM PuSE. sED Ac pI sc—oNNEcT 30' 125E FUSES T— 2TM CONVECTORS 24 3UNP BREAKER 2 ENPHASE IQ CABLE SINGLE DROP (LANOSI""'. n CELL 5' EN'HASE ID CABLE SINGLE DROP (P—T) 222' EN—E TER• 11—OR CAP 10 10 ENPHA.SEIO FEMAIECONNECTOP. 3 ENPHASE IO A�ALf CONNECTORS 0" ENPHASE IQ —E SEALS 222' HALO LURA GRIP, BIACN 17 %fl10, P/JL 105'IIe)BLACK 4 BORDEOS —. %R10 5' UNIVERSAL MOWIE C—IP. BLACK ° END TENNGOS.IWA ECT(ENDCP, ]bIGAM),MILL 10 T-BWT.BONDINGH M -E GROLWpWO WG, LOW PRORLE %REHARE CLIP AwIT N CAP.%R IS (L R PAIR) MICRMNVERTEIMILPEBG __OWARE, BOL"T ROOF # ROOF TYPE TILT PITCH I AZIMUTH ROOF FRAMING MODULE COUNT ARRAY SO, FT. 1 COMP SHINGLE 30' 7:12 312' 2X6@24" O.C. RAFTERS 24 504.48 2 ROLLED COMP 5' 1.5:12 222' 2X6@24" O.C. RAFTERS 10 210.20 3 ROLLED COMP 0" 0:12 222' 2X6@24" O.C. RAFTERS 17 357.34 4 ROLLED COMP 5' 1.5:12 42' 2X6@24" O.C. RAFTERS 10 210.20 TOTAL ROOF AREA SQ. FT. 2851 TOTAL ARRAY SQ. FT. 1282.22 ROOF COVER% 44.97 i i (N)VISIBLE LOCKABLE LABELED UTILITY AC DISCONNECT #2 (N) LOAD CENTE (N) VISIBLE LOCKABLE LABELED UTILITY AC DISCONNECT #1 (E) CON EDISON METER— I e \ (E) ISOLATED MAIN DISCONNECT) 36" FIRE OFFSET SITE PLAN NOTES 1. ALL OBSTRUCTIONS MUST BE VERIFIED BEFORE WORK COMMENCES 2. CONDUIT TO BE RUN IN ATTIC IF POSSIBLE 3. VISIBLE LOCKABLE LABELED UTILITY AC DISCONNECT WILL BE INSTALLED WITHIN 10' OF CON EDISON METER. 4. AC DISCONNECT SHALL BE READILY ACCESSIBLE 2417 5. REQUIRED ELECTRICAL CLEARANCE TO BE MAINTAINED 6. MAIN SERVICE PANEL LOCATION: BASEMENT 7. METER LOCATION: BASEMENT NOTE: EQUIPMENT LOCATIONS ARE DEFINED BUT MAY BE APPROXIMATE DUE TO EXISTING CONDITIONS —(N) PV MODULE EQUIPPED Wt (1) MICRO INVERTER PER (1) MODULES E -ROOF TO BE COMPLETED BEFORE INSTALLATION 1 zc 18" FIRE OFFSET 36" FIRE OFFSET IRE DEPARTMENT ACCESS POINT 4�1 67.80" TALESUN TM7G54M 450 MODULES SCALE: 1116" = l'-0" DESIGN ENGINEER MSSLING CONS V Li M 76 N. MEADOWBROOK DRIVE ALPINE UT 84004 swyssfing@wysslingconsulting.com (201) 874-3483 COA #0022571 SOLAR COMPANY/CLIENT SOLAQ RIVERTOWN SOLAR LLC 23 MAIN STREET IRVINGTON, NY SEPIASHVILI RESIDENCE 1965 EAST MAIN STREET MOHEGAN LAKE, NY 10547 COORDINATES: 41.319028,-73.857951 (914) 814-0716 SITE PLAN New Y.,k COA # D022571 Signed 1102025 DC SYSTEM SIZE: 27.450kW AC SYSTEM SIZE: 23.180kW %HJ: ALDEN JTILITY: CONED )RAWNBY: AKM NITIAL DESIGN DATE: 08/25/2025 REV: B PV -2 N CONED METER NUMBER: A71 B 11033990 12'-7" PROPERTY LINE / \\ 76'-11" / / O O MAIN HOUS DESIGN ENGINEER VVYSSLING 76 N. MEADOWBROOK DRIVE ALPINE UT 84004 svwyssfing@wyssfingconsijlting.com (201) 874-3483 COA #0022571 SOLAR COMPANYICLIENT 7. RIVERTOWN SOLAR LLC 23 MAIN STREET IRVINGTON. NY SEPIASHVILI RESIDENCE 1966 EAST MAIN STREET MOHEGAN LAKE, NY 10547 COORDINATES: 41.319028,-73.857951 (914) 814-0716 PROPERTY PLAN Wyssling J+ulting,PLLC 76NAleadaw6eY -e Alpine OT 8400- NewYo, AN 0022571 Signed 111312025 DC SYSTEM SIZE: 27.450kW AC SYSTEM SIZE: 23.180kW ALDEN CONED BY: AKM DESIGN DATE: 08/25/2025 REV: B PV -3 N CONED METER NUMBER:A71B 11033990 PV MODULES: (61) TALESUN TM7G54M 450 ROOF TYPE(S): COMP SHINGLE $ ROLLED COMP ROOF CONDITION: UNSUITABLE MOUNTING TYPE(S): IRONRIDGE OUICKMOUNT HALO ULTRAGRIP WITH IRONRIDGE XR10 RAIL 8 IRONRIDGE FLAT ROOF ATTACHMENT (FIXED TILT LEGS) WITH IRONRIDGE XR10 RAIL FLASHING: IRONRIDGE ULTRAGRIP FLASHING ROOF HEIGHT: 25' ROOF FRAMING MATERIAL: WOOD DECKING THICKNESS: 112" TOTAL ATTACHMENTS: 184 MAX CANTILEVER DISTANCE: 16" 48" MAX SPACING 16" ATTIC MEMBER SPACING ATTACHMENT DESCRIPTION ROOF # ROOF TYPE TILT ARRAY TILT 1 COMP SHINGLE 30° 30° 2 ROLLED COMP 5° 5' 3 ROLLED COMP 0- 0- 4 ROLLED COMP 5- 5' ATTACHMENT DESCRIPTION :IMUTH ROOF FRAMING TOTAL POINTS MA> SPACII 312" 2X6@24" O.C. RAFTERS 57 48" 222° 2X6@24" O.C. RAFTERS 34 48" 222- 2X6@24" O.C. RAFTERS 59 48" 42° i 2X6@24" O.C. RAFTERS 34 48" 18" FIRE OFFSET y-36" FIRE OFFSET EXACT LOCATION OF ROOF FRAMING MAY VARY; INSTALLER TO FOLLOW ENGINEER (WHERE APPLICABLE) AND MANUFACTURER SCALE: 3132" = 1'-0" INSTRUCTIONSlGUIOELINES WHEN INSTALLING. SEPIASHVILI RESIDENCE 1966 EAST MAIN STREET MOHEGAN LAKE, NY 10547 COORDINATES: 41.319028, -73.857951 (914)814-0716 ATTACHMENT PLAN 9=:15-11 ►-� Wyssling fontiting, PLLC 76HWN d—b. MOP eAlpl-0184004 New Yo C 40022571 Si ned 1113/2025 DC SYSTEM SIZE: 27.450kW AC SYSTEM SIZE: 23.180kW AHJ: ALDEN JTILITY: CONED DRAWN BY: AKM NITIAL DESIGN DATE: 08/25/2025 REV: B PV -4 DESIGN ENGINEER MAX CANTILEVER ATTACHMENT MIN EMBEDMENT 16" (2) #14 SCREW 2„YSSLING 16” (2) #14 SCREW 2" 76 N. MEADOWBROOK DRIVE 16" (2) #14 SCREW 2,5" ALPINE UT 84004 swyssling@wysslingconsulting.com 16" (2) #14 SCREW 2" (201) 874-3483 COA #0022571 SOLAR COMPANY/CLIENT 50LAQ. RIVERTOWN SOLAR LLC 23 MAIN STREET IRVINGTON, NY 18" FIRE OFFSET y-36" FIRE OFFSET EXACT LOCATION OF ROOF FRAMING MAY VARY; INSTALLER TO FOLLOW ENGINEER (WHERE APPLICABLE) AND MANUFACTURER SCALE: 3132" = 1'-0" INSTRUCTIONSlGUIOELINES WHEN INSTALLING. SEPIASHVILI RESIDENCE 1966 EAST MAIN STREET MOHEGAN LAKE, NY 10547 COORDINATES: 41.319028, -73.857951 (914)814-0716 ATTACHMENT PLAN 9=:15-11 ►-� Wyssling fontiting, PLLC 76HWN d—b. MOP eAlpl-0184004 New Yo C 40022571 Si ned 1113/2025 DC SYSTEM SIZE: 27.450kW AC SYSTEM SIZE: 23.180kW AHJ: ALDEN JTILITY: CONED DRAWN BY: AKM NITIAL DESIGN DATE: 08/25/2025 REV: B PV -4 ROOF SECTIONS I R1, R2, R4 WIND SPEED: 115 MPH GENERAL ROOF MOUNT DETAIL NTS MOUNTING HARDWARE GROUND SNOW LOAD: 40 PSF ROOF TYPE: COMP SHINGLE ROOF LAYERS (IF APPLICABLE): 1 ROOF MOUNT PLAN VIEW DETAIL 6" MAX SPACE FROM ROOF SURFACE COMP SHINGLE (2) QUICKMOUNT RD STRUCTURAL LAG BOLT (#14 X 3" LONG) CONNECTED INTO ROOF FRAMING � ROOF SHEATHING QUICKMOUNT HALO ULTRAGRIP RAFTERITRUSS MOUNT SEE ROOF MOUNT CROSS SECTION DETAIL THIS SHEET FOR CONNECTION TO ROOF FRAMING QUICKMOUNT HALO ULTRAGRIP ROOF MOUNT MIN EMBEDMENT DEPTHIROOF FRAMING SEE TABLE ON ATTACHMENT PLAN PAGE NOTE: ALL ROOF PENETRATIONS MUST BE SEALED OR FLASHED USING APPROVED MEANS ROOF MOUNT CROSS SECTION DETAIL NTS (2) QUICKMOUNT RD STRUL BOLT (#14 x 3" LONG) CONNECTED INTO ROOF FRAMING NTS ROOF MOUNT NTS DESIGN ENGINEER �SSLING maulmqA 76 N. MEADOWBROOK DRIVE ALPINE UT 84004 swyssling@ vryssling-nsulling. com (201) 874-3483 COA #0022571 SOLAR COMPANY/CLIENT �, Ir.l f_ r�,1•, j.., � RIVERTOWN SOLAR LLC 23 MAIN STREET IRVINGTON, NY SEPIASHVILI RESIDENCE 1966 EAST MAIN STREET MOHEGAN LAKE, NY 10547 COORDINATES: 41.319028,-73.857951 (914) 814-0716 MOUNTING DETAILS WysslinU C+nsulting, PLLC 76NVe4 , Dr— Alpmcur 84004 New Yuli COA # 0022571 Signed 1113/2025 DC SYSTEM SIZE: 27.450kW AC SYSTEM SIZE: 23 180k 4HJ: ALDEN JTILITY: CONED )RAWN BY: AKM NITIAL DESIGN DATE: 08/25/2025 REV: B PV -5 ROOF SECTIONS R3 I WIND SPEED: 109 MPH GENERAL ROOF MOUNT DETAIL NTS RAIL PV MODULE IRONRIDGE NORTH TILT LEG ANGLE VARIES, UP TO 30° GROUND SNOW LOAD: 40 PSF ROOF TYPE: COMP SHINGLE ROOF LAYERS (IF APPLICABLE): 1 I DESIGN ENGINEER 'SLING COA#0022571 ROOF MOUNT PLAN VIEW DETAIL E��1ruquiuRNEA NTS O O IRONRIDGE FLAT ROOF ATTACHMENT 76 N. MEADOWBROOK DRIVE ROOF MOUNT WITH (2) SCREWS CONNECTED TO ROOF FRAMING ALPINE UT 84004 svryssling@vvysslingconsulling.com (201) 874-3483 (E) ROOF FRAMING FINISHED ROOF ROOF SHEATHING IRONRIDGE QUICKMOUNT CEASE STAND OFF ROOF MOUNT. SEE ROOF MOUNT CROSS SECTION DETAIL THIS SHEET FOR CONNECTION TO ROOF FRAMING 1w IRONRIDGE XR RAIL IRONRIDGE SOUTH TILT LEG - IRONRIDGE FLAT ROOF ATTACHMENT MEMBRANE FLASHING I `(2)#i4 SCREWS PROVIDED BY MIN EMBEDMENT DEPTHIROOF FRAMING MANUFACTURER CONNECTED INTOROOF FRAMING SEE TABLE ON ATTACHMENT PLAN PAGE NOTE: ALL ROOF PENETRATIONS MUST BE SEALED OR FLASHED USING APPROVED MEANS ROOF MOUNT CROSS SECTION DETAIL NTS BOLT, 318-16 X 1.125' 1 WASHER, FLAT 3/8" X 1.25" FLAT ROOF ATTACHMENT, MEMBRANE Ldl" 1Wuftftye')' COA#0022571 O go SOLAR COMPANYICLIENT O O OO RIVERTOWN SOLAR LLC O O O O 23 MAIN STREET IRVINGTON, NY O O SEILI \ O�� RESIDENCE (2) #14 SCREWS PROVIDED BY 1966 EAST MAIN STREET MANUFACTURER CONNECTED INTO MOHEGAN LAKE, NY 10547 ROOF FRAMING COORDINATES: 41.319028,-73.B57951 (914) 814-0716 MOUNTING DETAILS EMBLED ILT LEG ROOF MOUNT NTS 76 H MeadowMonk 0nve AlpI-OT 84004 New Yar4 COA 4 D022571 Signed 11/3/2025 DC SYSTEM SIZE: 27.450kW AC SYSTEM SIZE: 23.180kW AHJ: ALDEN UTILITY: CONED DRAWN BY: AKM INITIAL DESIGN DATE: 08/25/2025 REV: B PV -5.1 N CONED METER NUMBER: F DESIGN ENGINEER �YSSLING ll . .. MODULE: (61) TALESUN TM7G54M 450 76 N. MEAOOWBROOK DRIVE INVERTER: (61) ENPHASE 108HC-72-M-US ALPINE UT 84004 COMBINER: (1) MINIMUM 200A LOAD CENTER swyssling@vysslingcon culling. com STRING 1: (9) MODULES ME (201) 874-3483 COA #0022571 STRING 2: (9) MODULES ® STRING 5 SOLAR COMPANYICLIENT STRING 3: (9) MODULES STRING 4: (9) MODULES ®"�. O 0L h1 STRING 5: (9) MODULES RIVERTOWN SOLAR LLC STRING 6: (8) MODULES 0 23 MAIN STREET STRING 7: (8) MODULES IRVINGTON, NY STR SCALE: 1/8" = V.0" SEPIASHVILI RESIDENCE 1966 EAST MAIN STREET MOHEGAN LAKE, NY 10547 COORDINATES: 41.3191)28,-73.857951 (914) 814-0716 STRING PLAN Nysslinj Ca sulting,PLLC 76NMeadow Y rve Alpine0T80004 New Y A b 0022571 Slgmd 11!3/2025 DC SYSTEM SIZE: 27.450kW AC SYSTEM SIZE: 23.180kW AHJ: ALDEN UTILITY: CONED DRAWN BY: AKM INITIAL DESIGN DATE: 08/25/2025 REVS EE -1 MODULE TYPE: (61) TALESUN TM7G54M 450 INVERTER TYPE: (61) ENPHASE 1O8HC-72-M-US 240V NOTE: ALL EQUIPMENT MUST BE UTILIZED IN ACCORDANCE WITH MANUFACTURER'S INTENDED USE AND DESIGN SPECIFICATIONS. CONDUCTO TAG # WIRES IN I MINIMUM TYPE, MINIMUM GROUND GROUND CONDUIT WIRE SIZE MATERIAL I WIRE SIZE ITYPE,MATER (N)240V/MINIMUM 200A LOAD CENTER NEMA 3R RATED MINIMUM 10KIAC LOCATION: SOUTH WEST WALL (N) 15A -2P ENVOY -IQ MONITOR JUNCTION BOX UP TO (1) MODULE PER MICRO INVERTER m VISIBLE -OPEN LOCKABLE LABELED AC DISCONNECT TO BE LOCATED IN A READILY ACCESSIBLE LOCATION WITHIN 10' OF THE CON EDISON METER (N) PV AC DISCONNECT 240V1200A NEMA 3R NON -FUSIBLE, 10KAIC VISIBLE -OPEN LOCKABLE, READILY ACCESSIBLE, LABELED 2 -POLE RAPID SHUTDOWN DEVICE LOCATION: SOUTH WEST WALL EATON DG224URK ©n (N) UTILITY PV AC DISCONNECT 240V/200A NEMA 3R 100KAIC FUSIBLE 125A FUSES VISIBLE -OPEN LOCKABLE, READILY ACCESSIBLE, LABELED 2 -POLE RAPID SHUTDOWN DEVICE LOCATION: INSIDE BASEMENT EATON DG224NRK © n N -G BOND (E)200A MAIN BREAKER PHASE LOCATION: INSIDE BASEMENT DESIGN ENGINEER AMPS (BEFORE 125% TOTAL WIRE AMPERAGE MINIMUM CONDUCTORS SAFETY FACTOR) AMPS RATING TABLE 310,15(B)(16) O20 C_y!■A+=• 14.22 17.78 25 20 Sy�.pS�Lq17Ic�N}�G 14.22 17.78 35 20 lSi camo SOlLlelSV ' 96.38 120.46 130 125 76 N. MEADOWBROOK DRIVE ALPINE UT 84004 swyssling@ wysslingconsulling. com (201) 874-3483 COA #0022571 SOLAR COMPANYICLIENT CONED METER NUMBER: A713 11033990 ` 0I +\ f ) RIVERTOWN SOLAR LLC (E) 200A RATED (E) CONED METER 23 MAIN STREET ISOLATED DISCONNECT 1201240V SINGLE IRVINGTON, NY m VISIBLE -OPEN LOCKABLE LABELED AC DISCONNECT TO BE LOCATED IN A READILY ACCESSIBLE LOCATION WITHIN 10' OF THE CON EDISON METER (N) PV AC DISCONNECT 240V1200A NEMA 3R NON -FUSIBLE, 10KAIC VISIBLE -OPEN LOCKABLE, READILY ACCESSIBLE, LABELED 2 -POLE RAPID SHUTDOWN DEVICE LOCATION: SOUTH WEST WALL EATON DG224URK ©n (N) UTILITY PV AC DISCONNECT 240V/200A NEMA 3R 100KAIC FUSIBLE 125A FUSES VISIBLE -OPEN LOCKABLE, READILY ACCESSIBLE, LABELED 2 -POLE RAPID SHUTDOWN DEVICE LOCATION: INSIDE BASEMENT EATON DG224NRK © n N -G BOND (E)200A MAIN BREAKER PHASE LOCATION: INSIDE BASEMENT 3 -WIRE SERVICE LINE SIDE TAP CONDUCTORS TAP CONNECTOR ORIGINATE OVERHEAD (E)200A MAIN BREAKER M tY FACILITY GROUND TO EXISTING SUB PANEL (E) GROUND ROD + INSIDE BASEMENT (E) WATER BOND GEC: #4 AWG CU SEPIASHVILI RESIDENCE 1966 EAST MAIN STREET MOHEGAN LAKE, NY 10547 COORDINATES: 41,319028, -73.857951 (914) 814-0716 THREE LINE DIAGRAM Signed 11/3/2025 DC SYSTEM SIZE: 27.450kW AC SYSTEM SIZE: 23.180kW 4HJ: ALDEN JTILITY: CONED )RAWN BY: AKM NITIAL DESIGN DATE: 08/25/2025 REV: S EE -2 PV MODULE INVERTER MODULE TALESUN TM7G54M MODEL ENPHASE MODEL 450 COEFFICIENT IQBHC-72-M-US MAX INPUT DC VOLTAGE 60V PMAX 45OW MAX DC CURRENT 14A VOC 39.6V 43,59 60, GOOD VMP 33.2V MAX OUTPUT POWER 380W CONT, IMP 13.56AMAXIMUM OUTPUT CURRENT 1.58A ISC 13.87A CEC EFFICIENCY 0.97 MAX SERIES FUSE 30A NOMINAL AC RATING VOLTAGE 240V ELECTRICAL CALCULATIONS TAG A FROM MODULES TO JUNCTION BOX LARGEST STRING: 9 MODULES NUMBER OF INVERTERS: 9 AMPS PER INVERTER: 1.58A 9' 1.58A = 14.22A'1.25 = 17.78A TOTAL AMPS CONDUCTOR SIZE: #12 AWG CONDUCTOR MAX: 25A, GOOD OCPD: 20A, GOOD TAG 8 FROM JUNCTION BOX TO AC COMBINER LARGEST STRING: 9 MODULES NUMBER OF INVERTERS: 9 AMPS PER INVERTER: 1.58A 9 ' 1.58A = 14.22A • 1.25 = 17.78A TOTAL AMPS CONDUCTOR SIZE: #10 AWG CONDUCTOR MAX: 35A, GOOD OCPD: 20A, GOOD TEMPERATURE CORRECTED VOC MODULE VOC COLDEST ADJUSTED INVERTER/ VOC COEFFICIENT I TEMPERATURE VOC OPTIMIZER MAX 39.6 -0.24 -17.00 43,59 60, GOOD CONED METER NUMBER: A71B 11033990 TAG C FROM AC COMBINER TO INTERCONNECTION TOTAL MODULES: 61 TOTALINVERTERS:61 AMPS PER INVERTER: 1.58A 61 ' 1.58A = 96.38A' 1.25 = 120.48A TOTAL AMPS CONDUCTOR SIZE: #1 AWG CONDUCTOR MAX: 130A, GOOD OCPD: 125A, GOOD INTERCONNECTION PER NEC 705.12 (B) BACK FEED REQUIRED 120.48A MINIMUM FUSE RATING I 125A DESIGN �Ya�SSLING Cii\clJ 79J'�wJ' 11 SINI 76 N. MEADOWBROOK DRIVE ALPINE UT 84004 swyssling@ wysslingconsulling. com (201) 874-3483 COA #0022571 SOLAR COMPANYICLIENT in t SOLAR RIVERTOWN SOLAR LLC 23 MAIN STREET IRVINGTON, NY SEPIASHVILI RESIDENCE 1966 EAST MAIN STREET MOHEGAN LAKE, NY 10547 COORDINATES: 41.319028,-73.857951 (914) 814-0716 ELECTRICAL NOTES New V.A WA # 0022571 Signed 11/3/2025 DC SYSTEM SIZE: 27.450kW AC SYSTEM SIZE: 23.180kW 4HJ: ALDEN JTILITY: CONED )RAWN BY: AKM NITIAL DESIGN DATE: 08/2512025 REV:6 EE -3 1E AT POINT OF INTERCONNECTION, MARKED AT DISCONNECTING MEANS [NEC 690.561 2) OWARNING DUAL PovvER souRcE AT POINT OF SECOND SOURCE IS PHOTOVOLTAIC SYSTEM INTERCONNECTION • • [NEC 705.12(C),690.591 3) EACH PV SYSTEM DISTRIBUTION EQUIPMENT DISCONNECTING MEANS SHALL PIVERTER0MtTr CONNEC110N.0ONar RELOCATETHISOVERCURRMVI ICE PLAINL(INDICATE WHETHER IN 91 &10101 THE OPEN (OFF) OR CLOSED BREAKER FROM THE INVERTER (ON) POSITION AND BE 7) AWARNING PERMANENTLY MARKED [NEC ELECTRICAL SHOCK HAZARD Tl I. III LI 11 690.13(B)] 4) • • AT EACH DC DISCONNECTING 690.13(B)] MEANS [NEC 690.13(B)] ARRAY: THE TITLE "SOLAR PV - 5) • • • AT EACH AC DISCONNECTING MEANS [NEC 690.13(B)] UTILIZED CAPITALIZED 6)• • • AT EXPOSED RACEWAYS, _ CABLE TRAYS, AND OTHER • • WIRING METHODS; SPACED AT ENVIRONMENT INVOLVED [NEC 110.21] THEY SHALL BE MAXIMUM 10 FT SECTION OR DISTRIBUTION EQUIPMENT WHERE SEPARATED BY PIVERTER0MtTr CONNEC110N.0ONar RELOCATETHISOVERCURRMVI ICE ENCLOSURES, WALLS, PARTITIONS, CEILINGS, OR BREAKER FROM THE INVERTER FLOORS [NEC 690.31(D)(2)) 7) AWARNING AT BUILDING OR TURE S STRUMAIN DISCONNECTING CMEA ELECTRICAL SHOCK HAZARD Tl I. III LI 11 [NEC 690.12(E), NEC 690.13(8)] 8) AT AC COMBINER PANEL [NEC DOWN THE ARRAY AND 690.13(B)] 9) Signed 11/3/2025 A PERMANENT WARNING LABEL AWARNING SHALL BE APPLIED TO THE ENVIRONMENT INVOLVED [NEC 110.21] THEY SHALL BE AC SYSTEM SIZE: 23.180kW DISTRIBUTION EQUIPMENT PIVERTER0MtTr CONNEC110N.0ONar RELOCATETHISOVERCURRMVI ICE ADJACENT TO THE BACK -FED AHJ: ALDEN BREAKER FROM THE INVERTER UTILITY: CONED [NEC 705.12(B)(2)] (BREAKER DRAWN BY: AKM INTERCONNECTION ONLY) 10) SOLAR PV SYSTEM EQUIPPED FOR PV SYSTEMS THAT SHUT WITH RAPID SHUTDOWN DOWN THE ARRAY AND CONDUCTORS LEAVING THE ARRAY: THE TITLE "SOLAR PV - SYSTEM IS EQUIPPED WITH " RAPID SHUTDOWN" SHALL UTILIZED CAPITALIZED CHARACTERS WITH A MINIMUM HEIGHT OF 318 IN. IN BLACK ON YELLOW BACKGROUND, AND THE REMAINING CHARACTERS SHALL BE CAPITALIZED WITH A MINIMUM HEIGHT OF 3/161N. IN BLACK ON WHITE BACKGROUND [NEC 690.12(D)] 11) A RAPID SHUTDOWN SWITCH . SHUTDOWN SHALL HAVE A LABELED - LOCATED ON OR NO MORE THAN 8 FT FROM THE SWITCH THAT INCLUDES THIS WORDING. THE LABEL SHALL BE REFLECTIVE, WITH ALL LETTERS CAPITALIZED AND HAVING A MINIMUM HEIGHT OF 318 IN., IN WHITE ON RED BACKGROUND [NEC 690.12(D)(2)] LABELING NOTES: 1. LABELS CALLED OUT ACCORDING TO ALL COMMON CONFIGURATIONS. ELECTRICIAN TO DETERMINE EXACT REQUIREMENTS IN THE FIELD PER CURRENT NEC AND LOCAL CODES AND MAKE APPROPRIATE ADJUSTMENTS. 2. LABELING REQUIREMENTS BASED ON THE NATIONAL ELECTRIC CODE, OSHA STANDARD 19010.145, ANSI Z535. DESIGN ENGINEER �YSSLING cariou ,lyIIImT( 76 N. MEADOWBROOK DRIVE ALPINE UT 84004 s�vyssling@wysslingconsulting.com (201) 874-3483 COA #0022571 SOLAR COMPANY/CLIENT RIVERTOWN SOLAR LLC 23 MAIN STREET IRVINGTON, NY SEPIASHVILI RESIDENCE 1966 EAST MAIN STREET MOHEGAN LAKE, NY 10547 COORDINATES: 41.319028,-73.857951 (914) 814-0716 LABELS 3. MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY Signed 11/3/2025 HAVING JURISDICTION. 4. LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE DC SYSTEM SIZE: 27.45OkW ENVIRONMENT INVOLVED [NEC 110.21] THEY SHALL BE AC SYSTEM SIZE: 23.180kW PERMANENTLY ATTACHED, WEATHER/SUNLIGHT RESISTANT, AND SHALL NOT BE HAND WRITTEN PER NEC 110.21(B) AHJ: ALDEN 5. APPLICABLE LABELS TO BE A MINIMUM LETTER HEIGHT OF 3/8", UTILITY: CONED WHITE ON RED BACKGROUND; REFLECTIVE, AND PERMANENTLY DRAWN BY: AKM AFFIXED [IFC 605.11.1.1] INITIAL DESIGN DATE: 08/25/2025 EE -4 REV: B CAUTION MULTIPLE SOURCES OF POWER POWER IS SUPPLIED TO THIS BUILDING FROM THE FOLLOWING SOURCES WITH DISCONNECTS AS SHOWN. ml RAPID SHUTDOWN INITIATOR AC DISCONNECT #2 AC COMBINER ` RAPID SHUTDOW INITIATOR AC /< DISCONNECT #1 MODULE METER ISOLATED MAIAI DISCONNECT 1966 EAST MAIN STREET MOHEGAN LAKE,NY 10547 LOCATION: MSP NEC 705.10 DESIGN ENGINEER ��oo V�pV�Lq�7/c�yN�} G lyo IdCI oullitl !S;(�I'Zsi 76 N. MEADOWBROOK DRIVE ALPINE UT 84004 swyssfing@wysslingconsulting.com (201) 874-3483 COA #0022571 SOLAR COMPANYICLIENT RIVERTOWN SOLAR LLC 23 MAIN STREET IRVINGTON, NY SEPIASHVILI RESIDENCE 1966 EAST MAIN STREET MOHEGAN LAKE, NY 10547 COORDINATES: 41.319028,-73.857951 (914) 814-0716 PLACARD Wyssling Gorkulting, PLLC 764klead..b,kk Df�,e Alpl-UT84004 Yew York AY D022571 Signed 1113/2025 DC SYSTEM %E'27 .450kW AC SYSTEM E: 23.180kW ALDEN CONED BY: AKM DESIGN DATE: 08/25/2025 REV: B EE -5 DESIGN ENGINEER XMNSLING GENERAL NOTES tt TIS, rl 11 0li -• 1. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND REVIEW ALL MANUFACTURER INSTALLATION DOCUMENTS PRIOR TO INITIATING CONSTRUCTION. • v ... 2. ALL COMPONENTS SHALL BE NEW AND LISTED BY A RECOGNIZED ELECTRICAL TESTING LABORATORY AND LISTED FOR THEIR SPECIFIC APPLICATION. 3. OUTDOOR EQUIPMENT SHALL BE NEMA 3R RATED OR BETTER. 4. ACCESS TO ELECTRICAL COMPONENTS OVER 150 VOLTS TO GROUND SHALL BE RESTRICTED TO QUALIFIED PERSONNEL. S. CONTRACTOR SHALL OBTAIN ELECTRICAL PERMITS PRIOR TO INSTALLATION AND SHALL COORDINATE ALL INSPECTIONS, TESTING COMMISSIONING, AND ACCEPTANCE WITH THE HOMEOWNER, UTILITY CO. AND CITY 76 N. MEAOOWBROOK DRIVE INSPECTORS AS NEEDED. ALPINE UT 84004 6. EACH MODULE TO BE GROUNDED USING THE SUPPLIED CONNECTION POINT PER THE MANUFACTURER'S REQUIREMENTS. ALL PV MODULES, EQUIPMENT, AND METALLIC COMPONENTS ARE TO BE BONDED. IF THE swyssling@wysslingconsulting.com EXISTING GROUNDING ELECTRODE SYSTEM CANNOT BE VERIFIED OR IS ONLY METALLIC WATER PIPING, IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE. (201) 874-3483 7. DC CONDUCTORS SHALL BE RUN IN EMT AND/OR MC (METAL CLAD CABLE) AND SHALL BE LABELED, COA #0022571 8. EXPOSED NON -CURRENT CARRYING METAL PARTS OF ELECTRICAL EQUIPMENT SHALL BE GROUNDED IN ACCORDANCE WITH APPLICABLE NEC. 9. CONFIRM LINE SIDE VOLTAGE AT THE ELECTRIC UTILITY SERVICE PRIOR TO CONNECTING INVERTER. VERIFY SERVICE VOLTAGE IS WITHIN INVERTER VOLTAGE OPERATIONAL RANGE. SOLAR COMPANYICLIENT 10. ELECTRICAL CONTRACTOR TO PROVIDE CONDUIT EXPANSION JOINTS AND ANCHOR CONDUIT RUNS AS REQUIRED PER CODE. 11. ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL MEANS DESIGNED AND LISTED FOR SUCH USE, AND FOR ROOF-MOUNTED SYSTEMS, WIRING MUST BE PERMANENTLY AND COMPLETELY_ _ �:,� i,%� �)',�`, I•�j HELD OFF OF THE ROOF SURFACE. 12. ALL ROOF PENETRATIONS MUST BE SEALED OR FLASHED. 13. EQUIPMENT MAY BE SUBSTITUTED FOR SIMILAR EQUIPMENT BASED ON AVAILABILITY, SUBSTITUTED EQUIPMENT SHALL COMPLY WITH DESIGN CRITERIA. 14. REMOVAL OF AN INTERACTIVE INVERTER OR OTHER EQUIPMENT SHALL NOT DISCONNECT THE BONDING CONNECTION BETWEEN THE GROUNDING ELECTRODE CONDUCTOR AND THE PHOTOVOLTAIC SOURCE AND/OR OUTPUT CIRCUIT GROUNDED CONDUCTORS. RIVERTOWN SOLAR LLC 15. WHENEVER A DISCREPANCY IN THE QUALITY OF EQUIPMENT ARISES ON THE DRAWING OR SPECIFICATIONS, THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AND INSTALLING ALL MATERIAL AND SERVICES 23 MAIN STREET REQUIRED BY THE STRICTEST CONDITIONS NOTED ON THE DRAWINGS OR IN THE SPECIFICATIONS TO ENSURE COMPLETE COMPLIANCE AND LONGEVITY OF THE OPERABLE SYSTEM REQUIRED BY THE ENGINEERS. IRVINGTON, NY 16. AC DISCONNECTSHALL BE LOCATED WITHIN 10' OF CON EDISON METER. AC DISCONNECT SHALL BE LOCATED ON SAME WALL OF HOUSE WHERE POSSIBLE. IF AC DISCONNECT CANNOT BE WITHIN 10' OF METER, THEN PHOTOS SHALL BE PROVIDED OF THE OBSTRUCTION FOR REVIEW. 17. IF APPLICABLE, ENERGY STORAGE SYSTEM (ESS) CAN BE USED DURING ON-GRID OPERATION TO SHIFT GENERATION FOR TIME OF USE (TOU) AND WILL NOT OPERATE OFF GRID. GENERAL ELECTRICAL NOTES SEPIASHVILI RESIDENCE 1. CONDUIT A AND B AMPS EQUAL TO LARGEST STRING ON TAG. 1966 EAST MAIN STREET 2. CONDUIT A SHALL BE RUN THROUGH ATTIC IF POSSIBLE. MOHEGAN LAKE, NY 10547 3. ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL MEANS DESIGNED AND/OR LISTED FOR SUCH USE, AND FOR ROOF-MOUNTED SYSTEMS, WIRING MUST BE PERMANENTLY AND COORDINATES: 41.319028,-73.857951 COMPLETELY HELD OFF OF THE ROOF SURFACE. 4. EQUIPMENT MAY BE SUBSTITUTED FOR SIMILAR EQUIPMENT BASED ON AVAILABILITY, SUBSTITUTED EQUIPMENT SHALL COMPLY WITH DESIGN CRITERIA. WIRE SIZES ARE BASED ON MINIMUMS AND ARE NOT MEANT TO LIMIT UPSIZING AS REQUIRED BY FIELD CONDITIONS/AVAILABILITY. (914) 814-0716 5. WIRING SHALL COMPLY WITH MAXIMUM CONTINUOUS CURRENT OUTPUT AT 25-C AND MAXIMUM VOLTAGE AT 605V; WIRE SHALL BE WET RATED AT 90°C. DESIGN NOTES 6. EXPOSED PHOTOVOLTAIC SYSTEM CONDUCTORS ON THE ROOF WILL BE TYPE 2 OR PV-TYPE WIRE. 7. PHOTOVOLTAIC SYSTEM CONDUCTORS SHALL BE IDENTIFIED AND GROUPED. THE MEANS OF IDENTIFICATION SHALL BE PERMITTED BY SEPARATE COLOR-CODING, MARKING TAPE, TAGGING OR OTHER APPROVED MEANS. 8. ALL CONDUCTORS AND TERMINATIONS SHALL BE RATED FOR INSTALL LOCATION 9. ALL EXTERIOR CONDUIT, FITTINGS, AND BOXES SHALL BE RAIN-TIGHT AND APPROVED FOR USE IN WET LOCATIONS. 10. ALL METALLIC RACEWAYS AND EQUIPMENT SHALL BE BONDED AND ELECTRICALLY CONTINUOUS. 11. WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, CONTRACTOR SHALL SIZE THEM ACCORDING TO APPLICABLE CODES. 12. REMOVAL OF A UTILITY-INTERACTIVE INVERTER OR OTHER EQUIPMENT SHALL NOT DISCONNECT THE BUILDING CONNECTION BETWEEN THE GROUNDING ELECTRODE CONDUCTOR AND THE PV SOURCE AND/OR OUTPUT CIRCUIT GROUNDED CONDUCTOR. 13. FOR GROUNDED SYSTEMS, THE PHOTOVOLTAIC SOURCE AND OUTPUT CIRCUITS SHALL BE PROVIDED WITH A GROUND-FAULT PROTECTION DEVICE OR SYSTEM THAT DETECTS A GROUND FAULT, INDICATES THAT FAULT HAS OCCURRED, AND AUTOMATICALLY DISCONNECTS ALL CONDUCTORS OR CAUSES THE INVERTER TO AUTOMATICALLY CEASE SUPPLYING POWER TO OUTPUT CIRCUITS. 14. FOR UNGROUNDED SYSTEMS, THE INVERTER IS EQUIPPED WITH GROUND FAULT PROTECTION AND A GFI FUSE PORT FOR GROUND FAULT INDICATION. 15. PV MODULE FRAMES SHALL BE BONDED TO RACKING RAIL OR BARE COPPER GEC/GEC PER THE MODULE MANUFACTURER'S LISTED INSTRUCTION SHEET. 16. PV MODULE RACKING RAIL SHALL BE BONDED TO BARE COPPER GEC VIA WEEB LUG, IL SCO GBL-4DBT LAY IN LUG, OR EQUIVALENT LISTED LUG. 17. THE PHOTOVOLTAIC INVERTER WILL BE LISTED AS UL 1741 COMPLIANT. 18. RACKING AND BONDING SYSTEM TO BE UL2703 RATED. 19. ANY REQUIRED GROUNDING ELECTRODE CONDUCTOR WILL BE CONTINUOUS, EXCEPT FOR SPLICES OR JOINTS AS BUSBARS WITHIN LISTED EQUIPMENT 20. WHEN BACKFEED BREAKER IS THE METHOD OF UTILITY INTERCONNECTION, THE BREAKERS SHALL NOT READ "LINE AND LOAD." 21. WHEN APPLYING THE 120% RULE, THE SOLAR BREAKER TO BE POSITIONED AT THE OPPOSITE END OF THE BUSBAR FROM THE MAIN BREAKER. 22. THE WORKING CLEARANCE AROUND THE EXISTING ELECTRICAL EQUIPMENT AS WELL AS THE NEW ELECTRICAL EQUIPMENT WILL BE MAINTAINED. 23, LISTED CONDUIT AND CONDUCTOR SIZES ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UPSIZING AS REQUIRED BY FIELD CONDITIONS/AVAILABILITY. 24. ENPHASE IQBHC-72-M-US INVERTERS HAVE INTEGRATED GROUND AND DOUBLE INSULATION. NO GEG OR EGO IS REQUIRED. THE DC CIRCUIT IS ISOLATED AND INSULATED FROM GROUND AND MEETS THE REQUIREMENTS OF NEC. 25. CALCULATIONS ARE BASED ON A) ASHRAE #2 AVERAGE HIGH = 32-C B)NEC TABLE 310.15(B)2(a) 75- DERATE FACTOR = 0.96 C) NEC TABLE NEC 310.15(B)(16) 75-C. 26. SUPPLEMENTAL GROUNDING ELECTRODE TO BE INSTALLED NO CLOSER THAN 6' FROM EXISTING WHEN REQUIRED. NEC 250.53(A)(2) DOES NOT REQUIRE IT IF CONTRACTOR CAN PROVE THAT A SINGLE ROD HAS A RESISTANCE TO EARTH OF 25 OHMS OR LESS. DC SYSTEM SIZE: 27.450kW 27, WHEN CABLE, INCLUDING PV CABLE(S), IS RUN BETWEEN ARRAYS OR TO JUNCTION BOXES IT SHALL BE ENCLOSED IN CONDUIT. [NEC 300.4,690,31(A) AND (C)j AC SYSTEM SIZE: 23.180kW 28. THE CABLE CONNECTORS USED ON THE OUTPUT SIDE OF THE OPTIMIZER OR MICROINVERTER TOGETHER WITH THE ARRAY CABLE USED BETWEEN THEM ARE OF THE SAME MANUFACTURER OR ARE LISTED FOR COMPATIBILITY. [NEC 690.33(C)) AHJ: ALDEN UTILITY: CONED 29. SOME WIRE CONNECTORS SUPPLY INSTRUCTIONS FOR THE PRELIMINARY PREPARATION OF CONDUCTORS, SUCH AS USE OF CONDUCTOR TERMINATION COMPOUND (ANTIOXIDANT COMPOUND). SOME CONNECTORS ARE SHIPPED PRE-FILLED WITH CONDUCTOR TERMINATION COMPOUND (ANTIOXIDANT COMPOUND). FOR NON-PREFILLEO CONNECTORS, CONDUCTOR TERMINATION COMPOUND MAY BE USED IF RECOMMENDED BY THE CONNECTOR MANUFACTURER AS PRELIMINARY PREPARATION OF THE CONDUCTOR. DRAWN BY: AKM INITIAL DESIGN DATE: 08/25/2025 REV: B PV-6 'Ire �l %.a 1% 70 DESIGN ENGINEER W�9 SLINVv srN,SULMG.A 76 N. MEADOWBROOK DRIVE ALPINE UT 84004 swyssling@wysslingconsulting.co. (201) 874-3463 COA #0022571 SOLAR COMPANYICLIENT SOLAQ RIVERTOWN SOLAR LLC 23 MAIN STREET IRVINGTON, NY SEPIASHVILI RESIDENCE 1966 EAST MAIN STREET MOHEGAN LAKE, NY 10547 COORDINATES: 41.319028,-73.857951 (914) 814-0716 SITE PHOTOS DC SYSTEM SIZE: 27.450kW AC SYSTEM SIZE: 23.180W CONED I BY: AKM DESIGN DATE: 08/25/2025 REV: B PV -7