HomeMy WebLinkAboutSigned Site Plan - 1966-1968 E Main St1033990 SYSTEM DESIGN 61 MODULES - 27.41, i0 kW DC, 23.180 kW AC SYSTEM SIZE SEPIASHVILI RESIDENCE - 1966 EAST MAIN STREET, MOHEGAN LAKE, NY 10547 VICINITY MAP NTS GOVERNING CODES 2017 NATIONAL ELECTRIC CODE 2020 RESIDENTIAL CODE OF NEW YORK STATE (2018 INTERNATIONAL RESIDENTIAL CODE) 2020 FIRE CODE OF NEW YORK STATE 2020 FUEL GAS CODE OF NEW YORK STATE 2020 EXISTING BUILDING CODE OF NEW YORK STATE 2020 ENERGY CONSERVATION CODE OF NEW YORK STATE 2020 MECHANICAL CODE OF NEW YORK STATE 2020 PLUMBING CODE OF NEW YORK STATE AS ADOPTED BY ALDEN INCLUDING ANY AMENDMENTS OR ADDITIONAL LISTED REQUIREMEP TS. DESIGNED IN ACCORDANCE WITH THE REQUIREMENTS OF CON EDISON UTILITY. EQUIPMENT IS COMPATIBLE WITH UL2703, UL1741, AND UL1703 AS APPLICABLE DESIGN CRITERIA WIND SPEED: 115 MPH GROUND SNOW LOAD: 40 PSF ASCE: 7-16 EXPOSURE CATEGORY: C BUILDING OCCUPANCY: R-3 CONSTRUCTION TYPE: TYPE V -B SPRINKLERS: NO SYSTEM SIZE: 27.450KW DC / 23.180KW AC SYSTEM SIZE PV MODULE: (61) TALESUN TM7G54M 450 INVERTER: (61) ENPHASE IQ8HC-72-M-US COMBINER: (1) MINIMUM 200A LOAD CENTER AC DISCONNECT: (1) 200A FUSED AC DISCONNECT WITH 125A FUSES (1) 200A UNFUSED AC DISCONNECT ROOF STORIES: 2 ROOF TYPE(S): COMP SHINGLE & ROLLED COMP MOUNTING(S) & RACKING(S): IRONRIDGE QUICKMOUNT HALO ULTRAGRIP WITH IRONRIDGE XR10 RAIL & IRONRIDGE FLAT ROOF ATTACHMENT (FIXED TILT LEGS) WITH IRONRIDGE XR10 RAIL FLASHING: IRONRIDGE ULTRAGRIP FLASHING ROOF BEING REPLACED: YES Itis aviolationof the lawforanyperson, unless ROOF CONDITION: POOR ROOF HEIGHT: 25 FEET acting under the direction of a licensed INTERCONNECTION: LINE SIDE TAP MAIN SERVICE PANEL LOCATION: BASEMENT MAIN SERVICE PANEL RATING: (E) 200A MAIN BREAKER RATING: (E) 200A OCPD: 125A FUSE CONED METER NUMBER: A71B 11033990 ARRAY SHEET INDEX PV -1 COVER PAGE PV -2 SITE PLAN PV -3 PROPERTY PLAN PV -4 ATTACHMENT PLAN AZIMUTH 1 PV -5 MOUNTING DETAILS 312° PV -5.1 MOUNTING DETAILS 5° EE -1 STRING PLAN 3 EE -2 THREE LINE DIAGRAM 222° EE -3 ELECTRICAL NOTES 5° EE -4 LABELS EE -5 PLACARD PV -6 DESIGN NOTES PV -7 SITE PHOTOS h SPEC SPECIFICATION SHEETS SCOPE OF WORK SYSTEM SIZE: 27.450KW DC / 23.180KW AC SYSTEM SIZE PV MODULE: (61) TALESUN TM7G54M 450 INVERTER: (61) ENPHASE IQ8HC-72-M-US COMBINER: (1) MINIMUM 200A LOAD CENTER AC DISCONNECT: (1) 200A FUSED AC DISCONNECT WITH 125A FUSES (1) 200A UNFUSED AC DISCONNECT ROOF STORIES: 2 ROOF TYPE(S): COMP SHINGLE & ROLLED COMP MOUNTING(S) & RACKING(S): IRONRIDGE QUICKMOUNT HALO ULTRAGRIP WITH IRONRIDGE XR10 RAIL & IRONRIDGE FLAT ROOF ATTACHMENT (FIXED TILT LEGS) WITH IRONRIDGE XR10 RAIL FLASHING: IRONRIDGE ULTRAGRIP FLASHING ROOF BEING REPLACED: YES Itis aviolationof the lawforanyperson, unless ROOF CONDITION: POOR ROOF HEIGHT: 25 FEET acting under the direction of a licensed INTERCONNECTION: LINE SIDE TAP MAIN SERVICE PANEL LOCATION: BASEMENT MAIN SERVICE PANEL RATING: (E) 200A MAIN BREAKER RATING: (E) 200A OCPD: 125A FUSE CONED METER NUMBER: A71B 11033990 ARRAY TILT AZIMUTH 1 30° 312° 2 5° 222° 3 0° 222° 4 5° 42° professional, to alter an item in anyway. If an item bearing the seat of a Licensed professional is altered, the altering licensed professional shalL affix to their item their seat and the notation "altered by"foltowed bytheir signature and the date of such alteration, and a specific description of the alteration. DATE REVISION COMMENT DESIGN ENGINEER 76 N. MEADOWBROOK DRIVE ALPINE UT 84004 swyssling@wysslingconsulting.com (201) 874-3483 COA #0022571 SOLAR COMPANY/CLIENT RIVERTOWN SOLAR LLC 23 MAIN STREET IRVINGTON, NY SEPIASHVILI RESIDENCE 1966 EAST MAIN STREET MOHEGAN LAKE, NY 10547 COORDINATES: 41.319028,-73.857951 (914)814-0716 COVER PAGE Signed 10/31/2025 Expires 7/31/2027 ADDED FIRE SETBACKS 10/28/2025 B AND CHANGED DC SYSTEM SIZE: 27.450kW ATTACHMENT FOR ROOF AC SYSTEM SIZE: 23.180kW 3 AHJ: ALDEN UTILITY: CONED DRAWN BY: AKM INITIAL DESIGN DATE: 08/25/2025 PV -1 IN REV: B WEIGHT o•+.0 I LIDO MODULE PLUMBING VENT (TYP.) 0 67.80" x 44.65" DIMENSIONS A/C UNIT WEIGHT SATELLITE DISH OF ARRAY 2.57 PSF LEGEND ROOF VENT (TYP.) QUANTITY PLUMBING VENT (TYP.) 0 A/C UNIT SOLAR PV MODULE A/C TALESUN MODULE SATELLITE DISH IT, ELECTRICAL MAST '? CHIMNEY I08HC-72-M-US FIRECODE PATHWAY COMBINER BILL OF MATERIALS EQUIPMENT QUANTITY DESCRIPTION SKU DOMESTIC SOLAR PV MODULE 61 TALESUN MODULE TM7G54M 450 NO MICRO INVERTERS 61 ENPHASE I08HC-72-M-US I08HC-72-M-US NO COMBINER 1 MINIMUM 200A LOAD CENTER N/A NO AC DISCONNECT 1 200A FUSED AC DISCONNECT GF224NR NO FUSES 2 125A FUSES N/A NO TAPS 2 TAP CONNECTORS N/A NO COMBINER BREAKER 7 20A/2P BREAKER N/A NO WIRE a8 ENPHASE IQ CABLE SINGLE DROP (LANDSCAPE, 72 CELL) 0-12-20-200 NO WIRE 20 ENPHASE IQ CABLE SINGLE DROP (PORTRAIT) 0-12-10-240 NO ENPHASE ACCESSORIES s ENPHASE TERMINATOR CAP Q -TERM -10 NO ENPHASE ACCESSORIES 12 ENPHASE IQ FEMALE CONNECTORS Q -CONN -10F NO ENPHASE ACCESSORIES 12 ENPHASE IQ MALE CONNECTORS Q -CONN -10M NO ENPHASE ACCESSORIES 8 ENPHASE IQ CABLE SEALS Q -SEAL -10 NO ATTACHMENT 184 HALO ULTRA GRIP, BLACK QM -HUG -01 -Bi NO RAIL 46 XR10, RAIL 168" (14') BLACK XR-10-1688 NO SPLICE 40 BONDED SPLICE, XR10 XR10-BOSS-01-Mt NO MID CLAMP 100 UNIVERSAL MODULE CLAMP, BLACK UFO -CL -01 -Bi NO END CLAMP 4a END FASTENING OBJECT (END CLAMP, 30-40MM), MILL uFo-END-01-A1 No T -BOLT 184 T -BOLT, BONDING HARDWARE BHW-TB-03-A1 NO MLPE & GROUNDING 11 GROUNDING LUG, LOW PROFILE XR-LUG-03-A1 NO WIRE MANAGEMENT 122 XR WIRE CLIP XR-WC-01-B1 NO END CAP (PAIR) 22 END CAP, XR10 (L -R PAIR) XR-10-CAP01-B1 NO MLPE MOUNT 61 MICROINVERTER/MLPE BONDING HARDWARE, T -BOLT BHW-MI-01-A1 NO SITE PLAN NOTES (N) VISIBLE LOCKABL = LABELED UTILITY AC DISC )NNECT #2 (N) L )AD CENTE (N) VISIBLE LOCKABI i LABELED UTILITY AC DISC ONNECT #1 (E) CON EDISON ME (E) ISOLATI D MAIN DISCONNECT 1. ALL OBSTRUCTIONS MUST BE VERIFIED BEFORE WORK COMMENCES 2. CONDUIT TO BE RUN IN ATTIC IF POSSIBLE 3. VISIBLE LOCKABLE LABELED UTILITY AC DISCONNECT WILL BE INSTALLED WITHIN 10' OF CON E )ISDN METER. 4. AC DISCONNECT SHALL BE READILY ACCESSIBLE 24/7 5. REQUIRED ELECTRICAL CLEARANCE TO BE MAINTAINED 6. MAIN SERVICE PANEL LOCATION: BASEMENT 7. METER LOCATION: BASEMENT NOTE: EQUIPMENT LOCATIONS ARE DEFINED BUT MAY BE APPROXIMATE DUE TO EXISTING CONDIT DNS 36" FIRE OFFSET (N) PV MODULE EQUIPPED W/ (1) MICRO INVERTER PER (1) MODULES It is a violation of the law forperson, unless acting under the direction of a " need professional, to atter an item to any. y. kan item bearing the seat of a Licensed professional is altered, the altering licensed professional shall affix to their item their seat and the notation "attered by" followed 6y their signature and the date of such, alteration, and a specific description of the alteration. SCALE: 1/16" = V-0" RE -ROOF TO BE COMPLETED BEFORE INSTALLATION 8" FIRE OFFSET FIRE OFFSET FIRE DEPARTMENT ACCESS POINT I ''1 T 67.80" TALESUN TM7G54M 450 MODULES APPROVED Resolution Number lb - 17— Date yDate 7 PIVEQ7'4 i RIVERTOWN SOLAR LLC 23 MAIN STREET IRVINGTON, NY SEPIASHVILI RESIDENCE 1966 EAST MAIN STREET MOHEGAN LAKE, NY 10547 COORDINATES: 41.319028,-73.857951 (914) 814-0716 SITE PLAN Signed 10/31/2025 Expires 7/31/2027 DC SYSTEM SIZE: 27.450kW AC SYSTEM SIZE: 23.180kW AHJ: ALDEN UTILITY: CONED DRAWN BY: AKM INITIAL DESIGN DATE: 08/25/2025 PV -2 M CONED METER NUMBER: A71 11033990 PROPERTY LIN 4'-7" 57'-11" MAIN HOUS 111'-8" \ � 2'-10" 12'-7" \ v '\ \ 76'-11" v v \ D . ® \ It is a violation of the lawfor any person, unless ®® \ acting under the direction of a licensed \ professional, to alter an itern in any way. If an item bearing the seat of a licensed professional >0 v v \ is altered, the tittering licensed professional shall affix to their item their seat and the notation \ altered by" followed by their signature and the date of such alteration, and a specific description of the alteration. . b \ v \ D ° \ \ \ 84'-11" v ni V? D D e e \ D .v D -07 521-411 D b � � v D ® b b ® v 0 D DC SYSTEM SIZE: 27.450kW AC SYSTEM SIZE: 23.180kW DRIVEWAY 76'-8" �"® ''/ APPROVED \ \ / Resolution Number_ -t- - 12- AHJ: ALDEN Date I �7 Q �— �� UTILITY: CONED 76 N. MEADOWBROOK DRIVE ALPINE UT 84004 swyssling@wysslingconsulting.com (201) 874-3483 COA #0022571 SEPIASHVILI RESIDENCE 1966 EAST MAIN STREET MOHEGAN LAKE, NY 10547 COORDINATES: 41.319028,-73.857951 (914)814-0716 PROPERTY PLAN Signed 10/31/2025 Expires 7/31/2027 ll DRAWN BY: AKM INITIAL DESIGN DATE: 08/25/2025 REV: B SCALE: 1/16" = V-0" PV -3 U • ATTACHMENT DESCRIPTION ROOF ROOF TYPE TILT ARRAY JAZIMUTH ROOF FRAMING TOTAL MAX MAX ATTACHMENT MIN # TILT POINTS SPACING CANTILEVER EMBEDMENT CONED METER NUMBER: A71B 11033990 1 COMP SHINGLE 30° 30° 312° 2X6@24" O.C. RAFTERS 57 48" 16" (2) #14 SCREW 2" PV MODULES: (61) TALESUN TM7G54M 450 ROOF TYPE(S): COMP SHINGLE & ROLLED COMP ROOF CONDITION: UNSUITABLE MOUNTING TYPE(S): IRONRIDGE QUICKMOUNT HALO ULTRAGRIP WITH IRONRIDGE XR10 RAIL & IRONRIDGE FLAT ROOF ATTACHMENT (FIXED TILT LEGS) WITH IRONRIDGE XR10 RAIL FLASHING: IRONRIDGE ULTRAGRIP FLASHING ROOF HEIGHT: 25' ROOF FRAMING MATERIAL: WOOD DECKING THICKNESS: 1/2" TOTAL ATTACHMENTS: 184 MAX CANTILEVER DISTANCE: 16" 48" MAX SPA, 16" Al 1 IV . VI , %VIINV 2 1 ROLLED COMP 1 50 1 5° 3 1 ROLLED COMP 1 00 1 0- 4 1 ROLLED COMP 1 5° 1 5- 2220 2X6@24" O.C. RAFTERS 1 34 2220 2X6@24" O.C. RAFTERS 1 59 420 12X6@2411 O.C. RAFTERS 1 34 W (4) 48" 1 16" 1 (2) #14 SCREW 48" 1 16" 1 (2) #14 SCREW 48" 1 16" 1 (2) #14 SCREW It is a vlatation of the law for any person, unless acting under the direction of a licensed professionat, to atter an item in any way. If an item bearing the seat of a licensed professional is altered, the altering licensed professional shatt affix to their item their seat and the rotation "altered by"foltowed by their signature and the date of such alteration, and a specific description of the alteration. 18" FIRE OFFSET 36" FIRE OFFSET EXACT LOCATION OF ROOF FRAMING MAY VARY; INSTALLER TO FOLLOW ENGINEER (WHERE APPLICABLE) AND MANUFACTURER INSTRUCTIONS/GUIDELINES WHEN INSTALLING. 2" 2 5" 76 N. MEADOWBROOK DRIVE ALPINE UT 84004 swyssling@wysslingconsulting.com 2" (201) 874-3483 COA #0022571 SEPIASHVILI RESIDENCE 1966 EAST MAIN STREET MOHEGAN LAKE, NY 10547 COORDINATES: 41.319028, -73.857951 (914)814-0716 ATTACHMENT PLAN Signed 10/31/2025 Expires 7/31/2027 DC SYSTEM SIZE: 27.450kW AC SYSTEM SIZE: 23.180kW APPROVED Resolution Number 12- AHJ: ALDEN Date i I 6.1 2-- 2-L� UTILITY: CONED DRAWN BY: AKM INITIAL DESIGN DATE: 08/25/2025 SCALE: 3/32" = V-0" PV -4 0 T�A7 ROOF SECTIONS R1, R2, R4 GENERAL ROOF MOUNT DETAIL NTS WIND SPEED: 115 MPH MOUNTING HARDWARE GTTINI PV MODULE (2) QUICKMOUNT RD STRUCTURAL LAG BOLT (#14 X 3" LONG) CONNECTED INTO ROOF FRAMING ROOF SHEATHING QUICKMOUNT HALO ULTRAGRIP RAFTER/TRUSS MOUNT SEE ROOF MOUNT CROSS SECTION DETAIL THIS SHEET FOR CONNECTION TO ROOF FRAMING NOTE: ALL ROOF PENETRATIONS MUST BE SEALED OR FLASHED USING APPROVED MEANS QUICKMOUNT HALO ULTRAGRIP ROOF MOUNT MIN EMBEDMENT DEPTH/ROOF FRAMING SEE TABLE ON ATTACHMENT PLAN PAGE ROOF MOUNT CROSS SECTION DETAIL NTS GROUND SNOW LOAD: 40 PSF 6" MAX SPACE FROM ROOF SURFACE COMP SHINGLE ROOF TYPE: COMP SHINGLE ROOF LAYERS (IF APPLICABLE): 1 ROOF MOUNT PLAN VIEW DETAIL (2) QUICKMOUNT RD STRUC, I VIXlI � BOLT (#14 x 3" LONG) CONNECTED INTO ROOF FRAMING NTS It is a violation of the lawforany person, finless acting under the direction of a licensed professional, to alter an item in any way. If an iters bean ng the seat of a licensed professional is altered, the altering licensed professional shall. affix to their item their seal and the notation "altered by" fotlowed by their signature and the date of such alteration, and a specific description of the alteration. DESIGN ENGINEER 76 N. MEADOWBROOK DRIVE ALPINE UT 84004 swyssling@wyssfingconsulting.com (201) 874-3483 COA #0022571 SOLAR COMPANY/CLIENT RIVERTOWN SOLAR LLC 23 MAIN STREET IRVINGTON, NY SEPIASHVILI RESIDENCE 1966 EAST MAIN STREET MOHEGAN LAKE, NY 10547 COORDINATES: 41.319028,-73.857951 (914)814-0716 MOUNTING DETAILS Signed 10/31/2025 Expires 7/31/2027 APPROVED DC SYSTEM SIZE: 27.450kW R+gIetinn NemAC SYSTEM SIZE: 23.180kW AHJ: ALDEN UTILITY: CONED ROOF MOUNT DRAWN BY: AKM INITIAL DESIGN DATE: 08/25/2025 NTS PV -5 0 ROOF SECTIONS liRI WIND SPEED: 109 MPH GENERAL ROOF MOUNT DETAIL NTS RAI L PV MODULE IRONRIDGE NORTH TILT LEG ANGLE VARIES, UP TO 30- (E) ROOF FRAMING ROOF SHEATHING GROUND SNOW LOAD: 40 PSF FIN SHED ROOF IRONRIDGE QUICKMOUNT QBASE STAND OFF ROOF MOUNT. SEE ROOF MOUNT CROSS SECTION DETAIL THIIS SHEET FOR CONNECTION TO ROOF FRAMING IRONRIDGE XR RAIL IRONRIDGE SOUTH TILT LEG IRONRIDGE FLAT ROOF ATTACHMENT MEMBRANE FLASHING MIN EMBEDMENT DEPTH/ROOF FRAMING SEE TABLE ON ATTACHMENT PLAN PAGE NOTE: ALL ROOF PENETRATIONS MUST BE SEALED OR FLASHED USING APPROVED MEANS ROOF MOUNT CROSS SECTION DETAIL NTS (2) #14 SCREWS PRC /IDED BY MANUFACTURER CC JNECTED INTO ROOF FRAMING ROOF TYPE: COMP SHINGLE BOLT, 3/8-16 X 1.125" F WASHER, FLAT 3/8" X 1.25' c FLAT ROOF ATTACHMENT, MEMBRANE It is a violation of the taw for any person, icnl acting under the direction of a licensed professional, to atter an itern in any way. if a item bearing the seal of a licensed professic is altered, the altering licensed professional affix to their item their seat and the natation "altered by" followed bytheir signature; and date of such alteration, and a specific description of the alteration. ROOF LAYERS (IF APPLICABLE): 1 ROOF MOUNT PLAN VIEW DETAIL NTS IRONRIDGE FLAT ROOF ATTACHMENT ROOF MOUNT WITH (2) SCREWS CONNECTED TO ROOF FRAMING ��j, .� �..,,�EWS PROVIDED BY MANUFACTURER CONNECTED INTO ROOF FRAMING EMBLED 'ILT LEG DESIGN ENGINEER 76 N. MEADOWBROOK DRIVE ALPINE UT 84004 swyssling@wysslingconsulting.com (201) 874-3483 COA #0022571 SOLAR COMPANY/CLIENT RIVERTOWN SOLAR LLC 23 MAIN STREET IRVINGTON, NY SEPIASHVILI RESIDENCE 1966 EAST MAIN STREET MOHEGAN LAKE, NY 10547 COORDINATES: 41.319028, -73.857951 (914) 814-0716 MOUNTING DETAILS Signed 10/31/2025 Expires 7/31/2027 APPROVED DC SYSTEM SIZE: 27.450kW RgWutlan Number, 2-�,.i Z_ Date 41 1. �, AC SYSTEM SIZE: 23.180kW I ROOF MOUNT NTS AHJ: ALDEN UTILITY: CONED El DRAWN BY: AKM INITIAL DESIGN DATE: 08/25/2025 REV: B PV -5.1 1 CONED METER NUMBER: A71 11033990 MODULE: (61) TALESUN TM7G54M 450 INVERTER: (61) ENPHASE IQ8HC-72-M-US COMBINER: (1) MINIMUM 200A LOAD CENTE STRING 1: (9) MODULES ME STRING 2: (9) MODULES STRING 3:(9) MODULES STRING 4:(9) MODULES STRING 5:(9) MODULES STRING 6: (8) MODULES STRING 7:(8) MODULES STR STRING 7 V I I \ I Im%.7 J STRING 2— STF SCALE: 1/8" = l'-0" DESIGN ENGINEER 76 N. MEADOWBROOK DRIVE ALPINE UT 84004 swyssling@wysslingconsulting.com (201) 874-3483 COA #0022571 SOLAR COMPANY/CLIENT PIVEPTOWN RIVERTOWN SOLAR LLC 23 MAIN STREET IRVINGTON, NY SEPIASHVILI RESIDENCE 1966 EAST MAIN STREET MOHEGAN LAKE, NY 10547 COORDINATES: 41.319028,-73.857951 (914)814-0716 STRING PLAN Signed 10/31/2025 Expires 7/31/2027 DC SYSTEM SIZE: 27.450kW AC SYSTEM SIZE: 23.180kW AHJ: ALDEN UTILITY: CONED DRAWN BY: AKM INITIAL DESIGN DATE: 08/25/2025 EE -1 U r'7WAA MODULE TYPE: (61) TALESUN TM7G54M 450 INVERTER TYPE: (61) ENPHASE IQ8HC-72-M-US 240V TAG # WIRES IN CONDUIT MIN VIUM WIRI SIZE TYPE, MATERIAL MINIMUM GROUND WIRE SIZE GROUND TYPE,MATERIAL CONDUIT AMPS (BEFORE 125% SAFETY FACTOR) TOTAL AMPS WIRE AMPERA(3E RATING TABLE 310.15(B)(16) MINIMUM OCPD NOTE: ALL EQUIPMENT MUST BE UTILIZED IN ACCORDANCE WITH A 3 #12 %WG Q CABLE #6 AWG BARE CU FREE AIR 14.22 17.78 25 20 MANUFACTURER'S INTENDED USE AND DESIGN SPECIFICATIONS. B 3 #10 kWG THWN-2, CU #12 AWG THWN-2, CU 3/4 EMT 14.22 17.78 35 20 C 4 #1 , kWG THWN-2, CU #6 AWG THWN-2, CU 1 1/4 EMT 96.38 120.48 130 125 (N)240V/MINIMUM 200A LOAD CENTER NEMA 3R RATED MINIMUM 10KIAC LOCATION: SOUTH WEST WALL CONED METER NUMBER: A71B 11033990 (E) 200A RATED ISOLATED DISCONNECT (E)200A MAIN BREAKER LOCATION: INSIDE BASEMENT LINE SIDE TAP TAP CONNECTOR 91 VISIBLE -OPEN LOCKABLE LABELED AC DISCONNECT TO BE LOCATED IN A READILY ACCESSIBLE LOCATION WITHIN 10' OF THE CON EDISON METER (N) PV AC DISCONNECT 240V/200A NEMA 3R NON -FUSIBLE, 10KAIC VISIBLE -OPEN LOCKABLE, READILY ACCESSIBLE, LABELED 2 -POLE RAPID SHUTDOWN DEVICE OCATION: SOUTH WEST WALL EATON DG224URK I.�I.,, I ... JUNCTION BOX (N) UTILITY PV AC DISCONNECT 240V/200A NEMA 3R 100KAIC FUSIBLE 125A FUSES VISIBLE -OPEN LOCKABLE, READILY ACCESSIBLE, LABELED 2 -POLE RAPID SHUTDOWN DEVICE LOCATION: INSIDE BASEMENT EATON DG224NRK 0 N -G BOND (E)200A MAIN BREAKER TO EXISTING SUB PANEL INSIDE BASEMENT (E) CONED METER 120/240V SINGLE PHASE 3 -WIRE SERVICE CONDUCTORS ORIGINATE OVERHEAD K )I FACILITY GROUND (E) GROUND ROD + (E) WATER BOND GEC: #4 AWG CU It is a violation of the taw for any person, unless acting under the direction of a licensed professional, to after an item in any way. If an item nearing the seat of a licensed professional is altered, the tittering licensed professional shalt affix to their item their seal and the notation "altered by"fotto ed bytheir signature and the date of such alteration, and a specific description of the alteration. APPRQVTM ftsdution Number �2-I DESIGN ENGINEER 76 N. MEADOWBROOK DRIVE ALPINE UT 84004 swyssling@wysslingconsulting.com (201) 874-3483 COA #0022571 SOLAR COMPANY/CLIENT RIVERTOWN SOLAR LLC 23 MAIN STREET IRVINGTON, NY SEPIASHVILI RESIDENCE 1966 EAST MAIN STREET MOHEGAN LAKE, NY 10547 COORDINATES: 41.319028,-73.857951 (914) 814-0716 THREE LINE DIAGRAM Signed 10/31/2025 Expires 7/31/2027 DC SYSTEM SIZE: 27.450kW AC SYSTEM SIZE: 23.180kW J: ALDEN LITY: CONED BRAWN BY: AKM NITIAL DESIGN DATE: 08/25/2025 REV: B UP TO (1) MODULE PER MICRO INVERTER EE -2 PV MODULE INVERTER MODEL TALESUN TM7G54M 450 MODEL ENPHASE IQ8HC-72-M-US MAX INPUT DC VOLTAGE 60V PMAX 450W MAX DC CURRENT 14A VOC 39.6V MAX OUTPUT POWER 38OW VMP 33.2V MAXIMUM CONT. OUTPUT CURRENT 1.58A IMP 13.56A ISC 13.87A CEC EFFICIENCY 0.97 MAX SERIES FUSE RATING 30A NOMINAL AC VOLTAGE 240V ELECTRICAL CALCULATIONS TAG A FROM MODULES TO JUNCTION BOX LARGEST STRING: 9 MODULES NUMBER OF INVERTERS: 9 AMPS PER INVERTER: 1.58A 9 * 1.58A = 14.22A * 1.25 = 17.78A TOTAL AMPS CONDUCTOR SIZE: #12 AWG CONDUCTOR MAX: 25A, GOOD OCPD: 20A, GOOD TAG B FROM JUNCTION BOX TO AC COMBINER LARGEST STRING: 9 MODULES NUMBER OF INVERTERS: 9 AMPS PER INVERTER: 1.58A 9 * 1.58A = 14.22A * 1.25 = 17.78A TOTAL AMPS CONDUCTOR SIZE: #10 AWG CONDUCTOR MAX: 35A, GOOD OCPD: 20A, GOOD TEMPERATURE CORRECTED VOC MODULE VOC COLDEST ADJUSTED INVERTER/ RATING OPTIMIZER VOC COEFFICIENT TEMPERATURE VOC MAX 39.6 -0.24 -17.00 43.59 60, GOOD CONED METER NUMBER: A71 B 11033990 TAG C FROM AC COMBINER TO INTERCONNECTION TOTAL MODULES: 61 TOTAL INVERTERS: 61 AMPS PER INVERTER: 1.58A 61 * 1.58A = 96.38A * 1.25 = 120.48A TOTAL AMPS CONDUCTOR SIZE: #1 AWG CONDUCTOR MAX: 130A, GOOD OCPD: 125A, GOOD INTERCONNECTION PER NEC 705.12 (B) BACK FEED 120.48A REQUIRED AC MINIMUM FUSE 125A RATING It is a violation of the taw for any person, unless acting under the direction of a licensed professional, to atter ars item in any way. If an item bearing the seat of a licensed professional is altered, the altering licensed professional shall affix to their item their seat and the notation "altered by"fotlowed by their signature and the slate of such alteration, and a specific description of the atteration. APPROVED Resolution Number 2b -1 Date +I � 1 202. �. DESIGN ENGINEER 76 N. MEADOWBROOK DRIVE ALPINE UT 84004 swyssling@wysslingconsulting.com (201) 874-3483 COA #0022571 SOLAR COMPANY/CLIENT RIVERTOWN SOLAR LLC 23 MAIN STREET IRVINGTON, NY SEPIASHVILI RESIDENCE 1966 EAST MAIN STREET MOHEGAN LAKE, NY 10547 COORDINATES: 41.319028, -73.857951 (914) 814-0716 ELECTRICAL NOTES Signed 10/31/2025 Expires 7/31/2027 DC SYSTEM SIZE: 27.450kW AC SYSTEM SIZE: 23.180kW AHJ: ALDEN UTILITY: CONED DRAWN BY: AKM INITIAL DESIGN DATE: 08/25/2025 EE -3 Iz 1) 2) 3) 4) 5) 6) 7) ELECTRICAL SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION a AT POINT OF 9) INTERCONNECTION, MARKED AT DISCONNECTING MEANS [NEC 690.561 AT POINT OF INTERCONNECTION [NEC 705.12(C),690.591 EACH PV SYSTEM DISCONNECTING MEANS SHALL PLAINLY INDICATE WHETHER IN THE OPEN (OFF) OR CLOSED (ON) POSITION AND BE PERMANENTLY MARKED [NEC 690.13(B)] AT EACH DC DISCONNECTING MEANS [NEC 690.13(B)] AT EACH AC DISCONNECTING MEANS [NEC 690.13(B)] AT EXPOSED RACEWAYS, CABLE TRAYS, AND OTHER WIRING METHODS; SPACED AT MAXIMUM 10 FT SECTION OR WHERE SEPARATED BY ENCLOSURES, WALLS, PARTITIONS, CEILINGS, OR FLOORS [NEC 690.31(D)(2)] AT BUILDING OR STRUCTURE MAIN DISCONNECTING MEANS [NEC 690.12(E), NEC 690.13(B)] AT AC COMBINER PANEL [NEC 690.13(B)] 10) SOLAR PV SY� TEM EQUIPPED WITH RAPII I SHUTDOWN 11) TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUTDOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN ARRAY A PERMANENT WARNING LABEL SHALL BE APPLIED TO THE DISTRIBUTION EQUIPMENT ADJACENT TO THE BACK -FED BREAKER FROM THE INVERTER [NEC 705.12(B)(2)] (BREAKER INTERCONNECTION ONLY) FOR PV SYSTEMS THAT SHUT DOWN THE ARRAY AND CONDUCTORS LEAVING THE ARRAY: THE TITLE "SOLAR PV SYSTEM IS EQUIPPED WITH RAPID SHUTDOWN" SHALL UTILIZED CAPITALIZED CHARACTERS WITH A MINIMUM HEIGHT OF 3/8 IN. IN BLACK ON YELLOW BACKGROUND, AND THE REMAINING CHARACTERS SHALL BE CAPITALIZED WITH A MINIMUM HEIGHT OF 3/16 IN. IN BLACK ON WHITE BACKGROUND [NEC 690.12(D)] A RAPID SHUTDOWN SWITCH SHALL HAVE A LABELED LOCATED ON OR NO MORE THAN 8 FT FROM THE SWITCH THAT INCLUDES THIS WORDING. THE LABEL SHALL BE REFLECTIVE, WITH ALL LETTERS CAPITALIZED AND HAVING A MINIMUM HEIGHT OF 3/8 IN., IN WHITE ON RED BACKGROUND [NEC 690.12(D)(2)] APPROVED Resolution Number 16 Date It is is a violation of the late for any person, unless acting under the direction of a licensed professional, to after an item in any gray. If an item bearing the seat of a licensed professional is altered, the altering licensed professional shall affix to their item their sea[ and the notation "altered by" followed by their signature and the date of such alteration, and a specific description of the alteration. LABELING NOTES: 1. LABELS CALLED OUT ACCORDING TO ALL COMMON CONFIGURATIONS. ELECTRICIAN TO DETERMINE EXACT REQUIREMENTS IN THE FIELD PER CURRENT NEC AND LOCAL CODES AND MAKE APPROPRIATE ADJUSTMENTS. 2. LABELING REQUIREMENTS BASED ON THE NATIONAL ELECTRIC CODE, OSHA STANDARD 19010.145, ANSI Z535. 3. MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. 4. LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED [NEC 110.211 THEY SHALL BE PERMANENTLY ATTACHED, WEATHER/SUNLIGHT RESISTANT, AND SHALL NOT BE HAND WRITTEN PER NEC 110.21(6) 5. APPLICABLE LABELS TO BE A MINIMUM LETTER HEIGHT OF 3/8", WHITE ON RED BACKGROUND; REFLECTIVE, AND PERMANENTLY AFFIXED [IFC 605.11.1.11 DESIGN ENGINEER 76 N. MEADOWBROOK DRIVE ALPINE UT 84004 swyssling@wysslingconsulting.com (201) 874-3483 COA #0022571 SOLAR COMPANY/CLIENT I RIVERTOWN SOLAR LLC 23 MAIN STREET IRVINGTON, NY SEPIASHVILI RESIDENCE 1966 EAST MAIN STREET MOHEGAN LAKE, NY 10547 COORDINATES: 41-319028,-73.857951 (914) 814-0716 LABELS Signed 10/31/2025 Expires 7/31/2027 DC SYSTEM SIZE: 27.4501kW AC SYSTEM SIZE: 23.180kW AHJ: ALDEN UTILITY: CONED DRAWN BY: AKM INITIAL DESIGN DATE: 08/25/2025 EE -4 REV: B MULTIPLF: SOURCES OF POWER R IS SLPPLIED TO THIS BUILDING FROM THE FOLLOWING SOURCES WITH DISCONNECTS AS SHOWN, ID SHUTDOWN INITIATOR DISCONNECT #2 AC COMBINER RAPID SHUTDOWN - INITIATOR AC DISCONNECT #1 ISOLATED MAI DISCONNEC F MODULE 1966 EAST MAI 4 STREET MOHEGAN LAKE,NY 10547 LOCATION: NEC 705.10 It is €s violation of tho low for any person, unless acting tinder the direction of s licensed professional, to utter an item in any way. if an item bearing the seat of a licensed professional is altered, the altering licensed professional ,shatl affix to their item their seat and the notation "altered lay"followed by their signature and the date of such alteration, and a specific description of the alteration. APPROVED ReSDlutlon Number ,_-1� Date DESIGN ENGINEER 76 N. MEADOWBROOK DRIVE ALPINE UT 84004 swyssling@wysslingconsulting.com (201) 874-3483 COA #0022571 SOLAR COMPANY/CLIENT RIVERTOWN SOLAR LLC 23 MAIN STREET IRVINGTON, NY SEPIASHVILI RESIDENCE 1966 EAST MAIN STREET MOHEGAN LAKE, NY 10547 COORDINATES: 41-319028,-73.857951 (914) 814-0716 PLACARD Signed 10/31/2025 Expires 7/31/2027 DC SYSTEM SIZE: 27.450kW AC SYSTEM SIZE: 23.180kW J: ALDEN ILITY: CONED BRAWN BY: AKM NITIAL DESIGN DATE: 08/25/2025 EE -5 8 REV: B DESIGN ENGINEER GENERAL NOTESSLING %kc 0$1N S ULTI -A 1. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND REVIEW ALL MANUFACTURER INST \LLATION DOCUMENTS PRIOR TO INITIATING CONSTRUCTION. ` 2. ALL COMPONENTS SHALL BE NEW AND LISTED BY A RECOGNIZED ELECTRICAL TESTING LAB )RATORY AND LISTED FOR THEIR SPECIFIC APPLICATION. 3. OUTDOOR EQUIPMENT SHALL BE NEMA 3R RATED OR BETTER. 4. ACCESS TO ELECTRICAL COMPONENTS OVER 150 VOLTS TO GROUND SHALL BE RESTRICTE TO QUALIFIED PERSONNEL. MEADOWBROOK DRIVE 5. CONTRACTOR SHALL OBTAIN ELECTRICAL PERMITS PRIOR TO INSTALLATION AND SHALL C( ORDINATE ALL INSPECTIONS, TESTING COMMISSIONING, AND ACCEPTANCE WITH THE HOMEOWNER, UTILITY CO. AND CITY 76 N. ALPINE B 84004 INSPECTORS AS NEEDED. 6. EACH MODULE TO BE GROUNDED USING THE SUPPLIED CONNECTION POINT PER THE MA UFACTURER'S REQUIREMENTS. ALL PV MODULES, EQUIPMENT, AND METALLIC COMPONENTS ARE TO BE BONDED. IF THE swyssling@wysslingconsulting.com EXISTING GROUNDING ELECTRODE SYSTEM CANNOT BE VERIFIED OR IS ONLY METALLIC WR -ER PIPING, IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE. (201) 874-3483 7. DC CONDUCTORS SHALL BE RUN IN EMT AND/OR MC (METAL CLAD CABLE) AND SHALL BE LA[ ELED. COA #0022571 8. EXPOSED NON-CURRENT CARRYING METAL PARTS OF ELECTRICAL EQUIPMENT SHALL BE G '.OUNDED IN ACCORDANCE WITH APPLICABLE NEC. 9. CONFIRM LINE SIDE VOLTAGE AT THE ELECTRIC UTILITY SERVICE PRIOR TO CONNECTING IN IERTER. VERIFY SERVICE VOLTAGE IS WITHIN INVERTER VOLTAGE OPERATIONAL RANGE. SOLAR COMPANY/CLIENT 10. ELECTRICAL CONTRACTOR TO PROVIDE CONDUIT EXPANSION JOINTS AND ANCHOR CONDUI - RUNS AS REQUIRED PER CODE. 11. ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL MEANS DESIG JED AND LISTED FOR SUCH USE, AND FOR ROOF -MOUNTED SYSTEMS, WIRING MUST BE PERMANENTLY AND COMPLETELY Q 11 IP QTOWN HELD OFF OF THE ROOF SURFACE. 12. ALL ROOF PENETRATIONS MUST BE SEALED OR FLASHED.; 13. EQUIPMENT MAY BE SUBSTITUTED FOR SIMILAR EQUIPMENT BASED ON AVAILABILITY, SUBS- iTUTED EQUIPMENT SHALL COMPLY WITH DESIGN CRITERIA. LAQ 14. REMOVAL OF AN INTERACTIVE INVERTER OR OTHER EQUIPMENT SHALL NOT DISCONNECT T 1E BONDING CONNECTION BETWEEN THE GROUNDING ELECTRODE CONDUCTOR AND THE PHOTOVOLTAIC SOURCE AND/OR OUTPUT CIRCUIT GROUNDED CONDUCTORS. RIVERTOWN SOLAR LLC 15. WHENEVER A DISCREPANCY IN THE QUALITY OF EQUIPMENT ARISES ON THE DRAWING OR! PECIFICATIONS, THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AND INSTALLING ALL MATERIAL AND SERVICES 23 MAIN STREET REQUIRED BY THE STRICTEST CONDITIONS NOTED ON THE DRAWINGS OR IN THE SPECIFICP FIONS TO ENSURE COMPLETE COMPLIANCE AND LONGEVITY OF THE OPERABLE SYSTEM REQUIRED BY THE ENGINEERS. IRVINGTON, NY 16. AC DISCONNECT SHALL BE LOCATED WITHIN 10' OF CON EDISON METER. AC DISCONNECT S TALL BE LOCATED ON SAME WALL OF HOUSE WHERE POSSIBLE. IF AC DISCONNECT CANNOT BE WITHIN 10' OF METER, THEN PHOTOS SHALL BE PROVIDED OF THE OBSTRUCTION FOR REVIEW. 17. IF APPLICABLE, ENERGY STORAGE SYSTEM (ESS) CAN BE USED DURING ON -GRID OPERATIO J TO SHIFT GENERATION FOR TIME OF USE (TOU) AND WILL NOT OPERATE OFF GRID. GENERAL ELECTRICAL NOTES SEPIASHVILI RESIDENCE 1. CONDUIT A AND B AMPS EQUAL TO LARGEST STRING ON TAG. 1966 EAST MAIN STREET 2. CONDUIT A SHALL BE RUN THROUGH ATTIC IF POSSIBLE. MOHEGAN LAKE, NY 10547 COORDINATES: 41.319028, 73.857951 3. ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL MEANS DESIGN[ D AND/OR LISTED FOR SUCH USE, AND FOR ROOF -MOUNTED SYSTEMS, WIRING MUST BE PERMANENTLY AND COMPLETELY HELD OFF OF THE ROOF SURFACE. 4. EQUIPMENT MAY BE SUBSTITUTED FOR SIMILAR EQUIPMENT BASED ON AVAILABILITY, SUBS- 1TUTED EQUIPMENT SHALL COMPLY WITH DESIGN CRITERIA. WIRE SIZES ARE BASED ON MINIMUMS AND ARE NOT (914) 814-0716 MEANT TO LIMIT UPSIZING AS REQUIRED BY FIELD CONDITIONS/AVAILABILITY. 5. WIRING SHALL COMPLY WITH MAXIMUM CONTINUOUS CURRENT OUTPUT AT 25°C AND MAXIM UM VOLTAGE AT 600V; WIRE SHALL BE WET RATED AT 90°C. DESIGN NOTES 6. EXPOSED PHOTOVOLTAIC SYSTEM CONDUCTORS ON THE ROOF WILL BE TYPE 2 OR PV-TYPI WIRE. 7. PHOTOVOLTAIC SYSTEM CONDUCTORS SHALL BE IDENTIFIED AND GROUPED. THE MEANS Oi IDENTIFICATION SHALL BE PERMITTED BY SEPARATE COLOR -CODING, MARKING TAPE, TAGGING OR OTHER APPROVED MEANS. 8. ALL CONDUCTORS AND TERMINATIONS SHALL BE RATED FOR INSTALL LOCATION 9. ALL EXTERIOR CONDUIT, FITTINGS, AND BOXES SHALL BE RAIN -TIGHT AND APPROVED FOR l SE IN WET LOCATIONS. 10. ALL METALLIC RACEWAYS AND EQUIPMENT SHALL BE BONDED AND ELECTRICALLY CONTINI DUS. 11. WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, CONT '.ACTOR SHALL SIZE THEM ACCORDING TO APPLICABLE CODES. 12. REMOVAL OF A UTILITY -INTERACTIVE INVERTER OR OTHER EQUIPMENT SHALL NOT DISCONI ECT THE BUILDING CONNECTION BETWEEN THE GROUNDING ELECTRODE CONDUCTOR AND THE PV SOURCE AND/OR OUTPUT CIRCUIT GROUNDED CONDUCTOR. 13. FOR GROUNDED SYSTEMS, THE PHOTOVOLTAIC SOURCE AND OUTPUT CIRCUITS SHALL BE F ROVIDED WITH A GROUND -FAULT PROTECTION DEVICE OR SYSTEM THAT DETECTS A GROUND FAULT, INDICATES THAT FAULT HAS OCCURRED, AND AUTOMATICALLY DISCONNECTS ALL CONDUCTORS OR CAUSES THE INVERTER TO AUTOMATICALLY CEASE SUPPLYING POWER TO OUTPUT CIRCUITS. 14. FOR UNGROUNDED SYSTEMS, THE INVERTER IS EQUIPPED WITH GROUND FAULT PROTECTI( N AND A GFI FUSE PORT FOR GROUND FAULT INDICATION. 15. PV MODULE FRAMES SHALL BE BONDED TO RACKING RAIL OR BARE COPPER GEC/GEC PER' HE MODULE MANUFACTURER'S LISTED INSTRUCTION SHEET. 16. PV MODULE RACKING RAIL SHALL BE BONDED TO BARE COPPER GEC VIA WEEB LUG, IL SCO 3BL-4DBT LAY IN LUG, OR EQUIVALENT LISTED LUG. 17. THE PHOTOVOLTAIC INVERTER WILL BE LISTED AS UL 1741 COMPLIANT. 18. RACKING AND BONDING SYSTEM TO BE UL2703 RATED. APPROVED 19. ANY REQUIRED GROUNDING ELECTRODE CONDUCTOR WILL BE CONTINUOUS, EXCEPT FOR :PLICES OR JOINTS AS BUSBARS WITHIN LISTED EQUIPMENT Resolution Number Z 20. WHEN BACKFEED BREAKER IS THE METHOD OF UTILITY INTERCONNECTION, THE BREAKERS Date `i'� �v-I 2n 2 �o SHALL NOT READ "LINE AND LOAD." 21. WHEN APPLYING THE 120% RULE, THE SOLAR BREAKER TO BE POSITIONED AT THE OPPOSIT _ END OF THE BUSBAR FROM THE MAIN BREAKER. 22. THE WORKING CLEARANCE AROUND THE EXISTING ELECTRICAL EQUIPMENT AS WELL AS TH _ NEW ELECTRICAL EQUIPMENT WILL BE MAINTAINED. 23. LISTED CONDUIT AND CONDUCTOR SIZES ARE BASED ON MINIMUM CODE REQUIREMENTS AI D ARE NOT MEANT TO LIMIT UPSIZING AS REQUIRED BY FIELD CONDITIONS/AVAILABILITY. 24. ENPHASE IQ8HC-72-M-US INVERTERS HAVE INTEGRATED GROUND AND DOUBLE INSULATION NO GEG OR EGC IS REQUIRED. THE DC CIRCUIT IS ISOLATED AND INSULATED FROM GROUND AND MEETS THE REQUIREMENTS OF NEC. 25. CALCULATIONS ARE BASED ON A) ASHRAE #2 AVERAGE HIGH = 32°C B)NEC TABLE 310.15(B)2 a) 75° DERATE FACTOR = 0.96 C) NEC TABLE NEC 310.15(B)(16) 75°C. 26. SUPPLEMENTAL GROUNDING ELECTRODE TO BE INSTALLED NO CLOSER THAN 6' FROM EXIS "ING WHEN REQUIRED. NEC 250.53(A)(2) DOES NOT REQUIRE IT IF CONTRACTOR CAN PROVE THAT A SINGLE ROD HAS A RESISTANCE TO EARTH OF 25 OHMS OR LESS. DC SYSTEM SIZE: 27.450kW 27. WHEN CABLE, INCLUDING PV CABLE(S), IS RUN BETWEEN ARRAYS OR TO JUNCTION BOXES I . SHALL BE ENCLOSED IN CONDUIT. [NEC 300.4, 690.31(A) AND (C)] AC SYSTEM SIZE: 23.180kW 28. THE CABLE CONNECTORS USED ON THE OUTPUT SIDE OF THE OPTIMIZER OR MICROINVERT :R TOGETHER WITH THE ARRAY CABLE USED BETWEEN THEM ARE OF THE SAME MANUFACTURER OR ARE LISTED FOR AHJ: ALDEN COMPATIBILITY. [NEC 690.33(C)] 29. SOME WIRE CONNECTORS SUPPLY INSTRUCTIONS FOR THE PRELIMINARY PREPARATION OF CONDUCTORS, SUCH AS USE OF CONDUCTOR TERMINATION COMPOUND (ANTIOXIDANT COMPOUND). SOME UTILITY: CONED CONNECTORS ARE SHIPPED PRE -FILLED WITH CONDUCTOR TERMINATION COMPOUND (ANT DXIDANT COMPOUND). FOR NON-PREFILLED CONNECTORS, CONDUCTOR TERMINATION COMPOUND MAY BE USED IF RECOMMENDED BY THE CONNECTOR MANUFACTURER AS PRELIMINARY PREPARATION OF T 1E CONDUCTOR. IDRAWN BY: AKM INITIAL DESIGN DATE: 08/25/2025 REV: B PV -6 DESIGN ENGINEER 76 N. MEADOWBROOK DRIVE ALPINE UT 84004 swyssling@wysslingconsulting.com (201) 874-3483 COA #0022571 SOLAR COMPANY/CLIENT RIVERTOWN SOLAR LLC 23 MAIN STREET IRVINGTON, NY SEPIASHVILI RESIDENCE 1966 EAST MAIN STREET MOHEGAN LAKE, NY 10547 COORDINATES: 41.319028, -73.857951 (914)814-0716 SITE PHOTOS APPROVED Resolution Number Date +/ b I Z,o2 ti DC SYSTEM SIZE: 27.450kW AC SYSTEM SIZE: 23.180kW AHJ: ALDEN UTILITY: CONED DRAWN BY: AKM INITIAL DESIGN DATE: 08/25/2025 REV: B PV -7 r IEC61215/IEC61730/UL61730 a ISO 9001: 2015 Quality Management System e ISO 14001: 2015 Environment Management System + ISO 45001: 2018 Occupational Health and Safety Management Systems 12 Linear Performance Warranty Standard Performance Warranty 16BB Half -cut Cell Technology Lower LID/LeTID degradation and better log '.ightperformance Attenuation <1% (1st year) / <0.4%(Linea . Industry Leading High Yield Bifacial TOPCon cell technology, Dual -sided power generation gain from bac side depending on albedo, significantly reduce LCOE Excellent Anti -PID Performance 192 hours Anti -PID test Wider Application No water -permeability and high wear-resis ice, can be widely used in high -humid, windy an dusty area IP68 Junction Box High waterproof level ELECTRICAL CHARACTERISTICS Testing Condition STC 15% NMOT STC 490 NMOT STC 556 NMOT STC NMOT STC NMOT -- lmpp/A 14.51 15.20 15.89 16.58 17.28 V.oc/V 39.45 sc/A 14.13 39.45 39.45 39.45 39.45 14.81 15.48 16.15 16.83 (''Maximum Power (Pmax/ W) 430 326 435 330 440 334 445 338 450 341 Operating Voltage(Vmpp/V 32.68 31.10 32.81 31.30 32.94 31.50 33.07 31.70 33.20 31.90 Operating Current(Impp//yI 13.16 10.49 13.26 1 10.54 13.36 10.59 13.46 10.64 13.56 10.69 Open -Circuit Voltage )Voc/ fi 39.00 37.00 39.15 37.10 39.30 37.20 39.45 37.30 39.60 37.40 Short -Circuit Current (Isc/AP 13.67 11.02 13.72 11.06 13.77 11.10 13.82 11.14 13.87 11.18 Module Efficiency (%) 22.00 22.30 22.50 22.80 23.00 STC: Irradiance 1000W/m2, Spectra at AM1.5, Module Temperature 25'C_ Power output tolerance: 0-+5W, Test uncertainty for Pmax: ±3% NMOT: Irradiance 800W/m2, Spectra at AM1.5, Ambient Temperature 201C, Wind speed 1m/s REAR SIDE Pik NfREFERENCE T£1 445W FRONT) Pmax gain 5% Pmax/W 467 10% 15% 20% 25% 490 512 534 556 Vmpp/V 33.07 / V 33.07 33.07 33.07 33.07 -- lmpp/A 14.51 15.20 15.89 16.58 17.28 V.oc/V 39.45 sc/A 14.13 39.45 39.45 39.45 39.45 14.81 15.48 16.15 16.83 MECHANICAL CHARACTERISTICS Cell Type N -type Mono -Crystallin (16Busbar) No. of Cells 108pcs in series (6*18) Module Dimensions 1722*1134*30mm (67.80*44.65*1.18inches) Weight 24.5kg (54.01lbs) Front Glass Back G ass 2.Omm AR Coating Semi -tempered Glass 2.Omm Glazed Semi -tempered Glass Frame Anodized Aluminium Alloy Junction Box 1P68, 3 Bypass Diodes Output Cables 4mm2 (IEC), 12AWG(UL) 350mm(+),250mml-) or Customized Length Connectors T01 /LJ Q-3-CSY/MC4/MC4-EV02 1 'Pieces Per -Pallet.- 36 36(USA) Pieces Per Container(40'HQ) _;) 936 720 Electrical Performance TM7G54M/445W 16 14 12 - m 4 _ o = - 0 10 20 30 40 -1000W/m'-80UM/m1-600W/m2-400W1m2-200W/m' Vottag.1V1 16 14 12 10 3 'c o a 6 4 1 2 0 0 10 zo 30 0 - 75-C - 50-C _ 25-C MogOV) 480 420 360 no 240 3 in 120 w 0 _ awn a➢ -r The specification and key features described in this datasheet may deviate slightly and are not guaranteed. Due to ongoing innovation, R&D enhancement, Suzhou Talesun Solar Technologies Co., Ltd. reserves the right to make any adjustment to the information described herein at any time without notice. Please always obtain the most recent version of the datasheet which shall be duly incorporated into the binding contract made TALESUN by the parties governing all transactions related to the purchase and sale of the products described herein. DESIGN ENGINEER 76 N. MEADOWBROOK DRIVE ALPINE UT 84004 swyssling@wysslingconsulting.com (201)874-3483 APPROVED Resolution Number _21 L0 - Date %l !oI_�z Sn MODULE Maximun System Voltage 150OWDC Operating Temperature "' -400G+850C Maximun Series Fuse 30A Safety Protection Class Class II Mechanical Load* Front side 5400Pa, Back side 240OPa Refer. Bifaciatity Factor 80%±5% *Refer to the installation manual for details Tt k'PrC A`Mr�F c:,I ARL ,i TERISTICS Temperature Coefficient of Pmax; -0.29%/°C Temperature Coefficient of Voc '.i; -0.24%/0C +0.043%/0C Temperature Coefficient of Isc °! Nominal Module Operating Temperature(NMOT) 43120 C 1 'Pieces Per -Pallet.- 36 36(USA) Pieces Per Container(40'HQ) _;) 936 720 Electrical Performance TM7G54M/445W 16 14 12 - m 4 _ o = - 0 10 20 30 40 -1000W/m'-80UM/m1-600W/m2-400W1m2-200W/m' Vottag.1V1 16 14 12 10 3 'c o a 6 4 1 2 0 0 10 zo 30 0 - 75-C - 50-C _ 25-C MogOV) 480 420 360 no 240 3 in 120 w 0 _ awn a➢ -r The specification and key features described in this datasheet may deviate slightly and are not guaranteed. Due to ongoing innovation, R&D enhancement, Suzhou Talesun Solar Technologies Co., Ltd. reserves the right to make any adjustment to the information described herein at any time without notice. Please always obtain the most recent version of the datasheet which shall be duly incorporated into the binding contract made TALESUN by the parties governing all transactions related to the purchase and sale of the products described herein. DESIGN ENGINEER 76 N. MEADOWBROOK DRIVE ALPINE UT 84004 swyssling@wysslingconsulting.com (201)874-3483 APPROVED Resolution Number _21 L0 - Date %l !oI_�z Sn MODULE EN PHASE, IQ8HC Microinverter Our newest IQ8 Series Microinverters are the industry's first microgrid-forming`, software -defined microinverters with split -phase power conversion capability to convert DC power to AC power effiriently. The brain of the semiconductor -based microinverter is our proprietary application-specific integrated circuit (ASIC), which enables the microinverter to operate in grid -tied or off -grid modes. This chip is built in advanced 55 -nm technology with high-speed digital logic and has superfast response times to changing loads and grid events, alleviating constraints on battery sizing for home energy systems. Connect PV modules quickly and easily to the I08 Series Microinverters that have integrated MC4 connectors. I08 Series Microinverters redefine reliability standards with more than one million cumulative hours of power -on testing, enabling an industry-leading limited warranty of up to 25 years. I08 Series Microinverters are UL Listed as PV rapid shutdown equipment and conform with various regulations when installed according to the manufacturer's instructions. `Meets UL 1741 only when installed with IQ System Controller 2 or 3. © 2024 Enphase Energy. All rights reserved. Enphase, thee and CC logos, 10, and certain other marks listed at httpaWanphase.com/tmdemark-usage-guldelines are trademarks of Enphase Energy, Inc. in the U.S. and other countries. Data subject to change. Easy to Install Lightweight and compact wi plug -and -play connectors Power line Communication (F C) between components • Faster installation with simpir two -wire cabling High productivity and reliabii y - Produces power even when' a grid is down' s, and sown) • More than one million cumul< :ve hours of testing *tung€ • Class II double -insulated enc :sure • Optimized for the latest high- owered PV modules :ed by an Microgrid-farming • Complies with the latest adv, _ -,ced grid support • Remote automatic updates f- the latest grid requirements • Configurable to support a wi v range of grid profiles Meets CA Ruin 21(UL 1741 -SA and IEEE 1547:2018 (UL 1741-58) NOTE; 108 Series Microinverters cannot t mixed together with prayious generation 3f Enphase mierolnverters(107 Sort". 46 Se! s, and sown) in the some "on V la Mlcroirrim res SNP with data&. *tung€ that M"t North Amvloa xiEEE IS - V interconnection standard mqus� M& Region- speciNc adjvstme ms may be roque :ed by an Auttrombr Having Jonsdicticn(A4, ;r utility repreBBnP$t1Ye, according to the 60 IEEE 1547 Inte*connection standar An 10 Gateway is required to make th x changes during kolarratrbn. I 25 108HC-MC4-DSH-00047-5.0 N -US -2024-07-19 IQ8HC Microinverter Commonly used module pairings Y1 Module compatibility _ To meet compatibility, PV modules must be within the maximum input DC voltage and maximum module) listed vn- :. below. Module compatibility can be checked at https://enphase.com/installers/microinverters/calculator. MPPT voltage range -.. _.. V .._...73.-:-4� Operating range 211-264 V 18-58 Minimum/Maximum start voltage V 22,158 Maximum input DC voltage 47.68 v 60 Maximum continuous operating DC current A Maximum input DC short-circuit current A I 25 Maximum module. I A Overvoltage class DC port - ( II DC port backf®ed current mA 0 PV array configuration _ Ungrounded array; no additional DC side protection required; AC side protection requires max. 20 A per branch circuit Peak output power Maximum continuous output power Nominal grid voltage (L -L) Minimum and maximum grid voltage' Maximum continuous output current Nominal frequency Extended frequency range AC short-circuit fault current over three cycles Maximum units per 20 A (L -L) branch circuit' Total harmonic distortion Ovetvoltage class AC port AC port backfired current power factor setting Grid -tied powerfactor (adjustable) Peak efRclancy CEC weighted efficiency Nighttime power consumption VA 384 97.0 -. vn- 96.5 380 v _ 240, splitrahase (L^L),?W V 211-264 A 1,58 Hz 60 Ha 47.68 A mA 7-- - - % ri 2.70 <5 fit 18 1.0 0.851eading ... 0.85 lagging 366 360 208, single -phrase (L-tL) €2Cr' 183-229 '.73 97-3 - 97.2 97.0 -. 96.5 ?2.: 26 Ambient temperature range I 'Q'Fl -40 to 65 (-40 to 149) Relative humidity range '!. 4 t r 100 (condansing) DC ccnnector type - Staubli MC4 Dimensions (N=wxC3);weigM-- — — mm{ani: k12(M ` 175f6:0) 30(1.2)� kg1'ibi 1.1 M.43) Cooling l - Natural convection - no fans Approved for wet locations; Pollution degree - Yes, PD3 - Enclosure - Class 11 double -insulated, corrosion -resistant polymeric enclosure Envirorrm ntal eategory; UV exposure rating - NEMA Type 6: outdoor '108HC-72-M-QOM-US is undergoing compliance, end the specs are preliminary. This SKU is made in the USA, and the PCBA, Electrical Parts, and Enclosure are domestically manufactured to meet the requirements of eligilellfty to be considered for the ITC domestic content bonus adder. ] No enforced DC/AC ratio. 3 Nominal voltage range can be extended beyond nominal if required by the utility. 4 Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. IQBHC-MC4-DSH-00047-5.0-EN-US-2024-07-19 DESIGN ENGINEER 76 N. MEADOWBROOK DRIVE ALPINE UT 84004 swyssling@wysslingconsulting.com (201)874-3483 APPROVE]) Resolution Number_( Datey- I J3I 2�z INVERTER AN L IRON RIDGE Engineering Down to the Dock Low -slope roofs (0-60) are extremely common in residential and commercial buildings, but the roof construction and the structural system below vary significantly, creating a challenge for designing solar arrays. The IronRidge Flat Roof Attachment combines a high- strength cast aluminum base with a 16 -point fastening pattern to enable the widest range of design options on low - sloped roofs. In addition, it is compatible with most common low -slope roofing materials to ensure a system that is easy to integrate down to the deck. 12 -straight and 4 -angled fastening options provide maximum capacity d versatility with wood, steel, decks, beams, and even concrete slabs. Intertek Flat Roof Attact ment 11 Attachment Options Refer to table for selecting proper roof membrane. Contact support@ironridge.com for approved alternatives. Refer to table to see how regional conditions, tilt angle, and rail size impacts the span between attachments. Values based on 72 -cell modules in Wind Exposure Category B (ASCE 7-10) DESIGN ENGINEER 76 N. MEADOWBROOK DRIVE ALPINE UT 84004 swyssling@wysslingconsulting.com (201) 874-3483 ATTACHMENT Citi �1idtl� "1ill�� d P r Made from high-strength ca A aluminum, the 7" wide, heavy-duty b& ; delivers __- superior uplift and lateral cF )acity 5� compared to any other proc ct on the Comp2tible Roof Me nbraines Formed membrane covers re matched to major roofing brands to E isure a tested, engineered •i • KEE roofs.. ac litional sealant required. a t��1IBIi Refer to table for selecting proper roof membrane. Contact support@ironridge.com for approved alternatives. Refer to table to see how regional conditions, tilt angle, and rail size impacts the span between attachments. Values based on 72 -cell modules in Wind Exposure Category B (ASCE 7-10) DESIGN ENGINEER 76 N. MEADOWBROOK DRIVE ALPINE UT 84004 swyssling@wysslingconsulting.com (201) 874-3483 ATTACHMENT IRONRIDGE E Tilt Mount Si stem 'Trust your systern at -y angle. The IronRidge Tilt Mount System supports a wide range of solar module tilting angles, while also resit °ing the extreme wind and snow forces experienced over a building's lifetime. Every component has been carefully engineered and rigorously tested, and the entire system uses or y aluminum and stainless steel materials to resist corrosion. Roof Friendly Lightweight and compatible with industry -standard attachments. Strength Tested All components evaluated for superior structural performance. UL 2703 Listed System Meets newest effective UL 2703 standard. PE Certified Pre -stamped engineering lett rs available in most states. Design Assistant Online software makes it sim; le to create, share, and price projE ;ts. 25 -Year Warranty Products guaranteed to be fr( y of impairing defects. XR Rails & Tilt Legs XR Rails Attach directly to Tilt Legs. Available in three targeted sizes to support specific wind and snow loads. • Unique curved profile • Spanning capabilities up to 12' • Clear and black finish Grounding Clam s UFOs 64 Universal Fastening Objects secure and bond modules to rails_ • Fully assembled and lubricated • Single, universal size • Clear and black finish Acce3sohes BOSST Bonded Splices Bonded Structural Splices connect and bond XR Rails together. • Integrated bonding • No tools or hardware • Self -centering stop tab Resoures Design Assistant Stopper Sleeves t=) Tilt Legs �-' Tilt assembly to desired angle, up to 30 degrees_ Kits include South and North Tilt Leg and all hardware. • Available in multiple lengths for a wide angle range • Assembled South Tilt Legs include angle indicators • Legs are electrically bonded to rails CAMO =; Snap onto the UFO to transform into a bonded end clamp. • Bonds modules to rails • Sized to match modules • Clear and black finish Grounding Lugs i') Connects Tilt Mount system to equipment ground. • Low profile • Single tool installation • Mounts in any direction Go from rough layout to fully engineered system. For free. Go to 'salii3e.r� design Bond modules to rails while staying completely hidden. • Universal end -cam clamp • Tool -less installation • Fully assembled Ends Caps & Wire Clips Provide a finished look and organize electrical wires. • Simple snap -in installations • Clips hold up to ten 5mm wires • UV -stabilized polymer DESIGN ENGINEER 76 N. MEADOWBROOK DRIVE ALPINE UT 84004 swyssling@wysslingconsulting.com (201) 874-3483 APIZ®vED Resolution Number LV -12 Date } 1 L. 1 2 o 2- (a ATTACHMENT ,Aft, IRONRIDGE Release Lil shown for i G Halo Ulb 3GriV ZD STRUCTURAL SCREW PN RD -1430-01 ;OLD SEPARATELY >HOWN FOR REFERENCE ITEM NO DESCRIPTION =QTY IN KIT 1 QM Halo UltraGrip(Mill or Black) 1 PART NUMBER DESCRIPTION QM -HUG -01-M1 Halo UltraGrip - Mill QM -HUG -01-B1 Halo UltraGrip - Black © 2023 IronRidge, Inc. All rights reserved. Visit w , ir-patents com for patent information. 4 QM -HUG -01-B1 orQM-HUG-01-M1 Cr Sheet Rev 1 01 Property Value Material 300 Series Aluminium Finish Mill or Black 0 2023 IronRidge, Inc. All rights reserved. Visit www ir-patents-com for patent information- QM -HUG -01 -Bi or QM -HUG -01-M1 Cut Sheet Rev 1 01 DESIGN ENGINEER 76 N. MEADOWBROOK DRIVE ALPINE UT 84004 swyssling@wysslingconsulting.com (201) 874-3483 APPROVED Resolution Number ,Z{. -_LZ Date +1 ATTACHMENT AAL IRONRIDGE Solstr Is Not Always Sunny Over their lifetime, solar panels experience countless extreme weather events. Not just the worst storms in years, but the worst storms in 40 years. High winds capable of ripping panels from a roof, and snowfalls weighing enough to buckle a panel frame. A XR Rails® are the structural backbone preventing these results. They resist uplift, protect against buckling and safely and efficiently transfer loads into the building structure. Their superior spanning capability requires fewer'" roof attachments, reducing the number of roof penetrations and the amount of installation time. Compatible with Flat & Pitched Roofs XR Rails`"' are compatible with FlashFoot* and other pitched roof attachments. XR Rail° Family 11 XR Rail' Family Farce -Stabilizing Curve Sloped roofs generate both vertical and lateral forces on mounting rails which can cause them to bend and twist. The curved shape of XR Rails® is specially designed to increase strength in both____ directions while resisting the twisting. This unique feature ensures greater security during extreme weather and a longer system lifetime. IronRidge�' offers a range of tilt leg options for flat roof mounting applications. 6000 -Series Aluminum All XR Rails` , are made of 6000 -series aluminum alloy, with anodized options. Anodizing prevents corrosion, while also providing a more attractive appearance. Available in mill and black -anodized finish. �I The XR Rail° Family offers the strength of a curved rail in three targeted sizes. Each size supports specific design loads, while minimizing material costs. Depending on your location, there is an XR Rail° to match. XR'10 XR10 is a sleek, low -profile mounting rail, designed for regions with light or no snow. It achieves spans up to 6 feet, while remaining light and economical. • 6'spanning capability • Moderate load capability • Mill & black -anodized finish • Internal splices available Rail Selection Kcarilro, XR100 is a residential and commercial mounting rail. It supports a range of wind and snow conditions, while also maximizing spans up to 10 feet. • 10'spanning capability • Heavy load capability • Mill & black -anodized finish • Internal splices available ,liyt XR1000 is a heavyweight among solar mounting rails. It's built to handle extreme climates and spans up to 12 feet for commercial applications. • 12'spanning capability • Extreme load capability • Mill, non -anodized finish • Internal splices available The table below was prepared in compliance with applicable engineering codes and standards.` Values are based on the following criteria- ASCE 7-16, Gable Roof Flush Mount, Roof Zones 1 & 2e, Exposure B, Roof Slope of 8 to 20 degrees and Mean Building Height of 30 ft. Visit IronRidge.com for detailed certification letters. *Table is meant to be a simplified span chart for conveying general rail capabilities. Use approved certification letters for actual design guidance. DESIGN ENGINEER 76 N. MEADOWBROOK DRIVE ALPINE UT 84004 swyssling@wysslingconsulting.com (201)874-3483 APPROVED Resolution Number 2 u-_ I 2 - Date Date y I e 2 co RAIL