Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Signed Site Plans - Curry Honda Large-Scale Solar System
SHEET CATALOG INDEX NO. DESCRIPTION CS 01 GENERAL NOTES A-01 SITE PLAN A-02 ENLARGED SITE PIAN S-01 STRUCTURAL DETAILS & ARRAY PLAN E-01 STRINGING MAP E-02 ELECTRICAL MOUNTING DETAILS E-03 EQUIPMENT ELEVATION DETAILS E-04 THREE LINE DIAGRAM E-05 ELECTRICAL CALCULATION E-06 ELECTRICAL PLACARDS SS -01 SPEC SHEET - 01 SS -02 SPEC SHEET - 02 SS -03 SPEC SHEET - 03 SP -01 SAFETY PLAN SCOPE OF WORK: DC SYSTEM SIZE: 253.17kW AC SYSTEM SIZE: 200.00kW MODULES: (522)HANWHA QCELLS Q.PEAK DUO XL-G10.3/BFG 485W INVERTERS: (4)SOLAREDGE TECHNOLOGIES SE50KUS (120/208V, 3PH) OPTIMIZER: (264)SOLAREDGE P1101 POWER OPTIMIZER WIND SPEED: 114MPH SNOW LOAD: 30PSF MINIMUM TEMPERATURE: -15.80C MAXIMUM TEMPERATURE: 32.3°C APPLICABLE CODES: 2017 NEW YORK ELECTRICAL CODE 2020 NEW YORK BUILDING CODE 2020 NEW YORK FIRE CODE ADDITIONALLY, CONFORM TO ALL LOCAL ORDINANCES AND REQUIREMENTS AERIAL VIEW: v , tl� f PROPOSED PV LOCATION �A d � r 1 � � r i VICINITY MAP: PROPOSED PV LOCATION if i Ul.i C.ainpopd Hd _. , NEW PHOTOVOLATIC (PV) SYSTEM: 253.17kW (DC)/200.00 kW (AC) CURRY HONDA YORKTOWN (COM -41603) 3845 CROMPOND ROAD, YORKTOWN, NY 10598 APN: 35.08-1-01 [41.291126, -73.851721] GENERAL NOTES: I.. EXISTING PLUMBING VENTS, SKYLIGHTS, EXHAUST OUTLETS, VENTILATION INTAKE AIR OPENINGS SHALL NOT BE COVERED BY THF SOLAR PHOTOVOI TAIC SYSTEM. 2. INVERTERS, MOTOR GENERATORS, PV MODULES, AC MODULES AND AC MODULE SYSTEMS, DC COMBINERS, DC -TO -DC CONVERTERS, RAPID SHUTDOWN EQUIPMENT, DC CIRCUIT CONTROLLERS, AND CHARGE CONTROLLERS INTENDED FOR USE IN PV SYSTEMS SHALL BE LISTED OR BE EVALUATED FOR THE APPLICATION AND HAVE A FIELD LABEL APPLIED. [NEC 690.4(B)] 3. ALL OUTDOOR EQUIPMENT SHALL BE NEMA 3R RATED, INCLUDING ALL ROOF MOUNTED TRANSITION BOXES AND SWITCHES. 4. ALL EQUIPMENT SHALL BE PROPERLY GROUNDED AND BONDED IN ACCORDANCE WITH NEC ARTICLE 250. 5. PV SYSTEM DC CIRCUIT AND INVERTER OUTPUT CONDUCTORS AND EQUIPMENT SHALL BE PROTECTED AGAINST OVERCURRENT. [NEC 690.9(A)] 6. ALL PHOTOVOLTAIC (PV) MODULES SHALL BE MOUNTED ON THE ROOF, CARPORT, ETC. 7. THE UTILITY INTERACTIVE INVERTERS SHALL TRIP OR SHALL BE PERMITTED TO AUTOMATICALLY DISCONNECTED FROM ALL UNGROUNDED CONDUCTORS OF THE PRIMARY SOURCE WHEN ONE OR MORE OF THE PHASES OF THE PRIMARY SOURCE TO WHICH IT IS CONNECTED OPENS. THE INTERACTIVE ELECTRIC POWER PRODUCTION EQUIPMENT SHALL NOT BE RECONNECTED TO THE PRIMARY SOURCE UNTIL ALL THE PHASES OF THE PRIMARY SOURCE TO WHICH IT IS CONNECTED ARE RESTORED. [NEC 705.40] 8. EQUIPMENT DISCONNECTING MEANS SHALL HAVE RATINGS SUFFICIENT FOR THE MAXIMUM CIRCUIT CURRENT, VOLTAGE, AND AVAILABLE FAULT CURRENT. THE DISCONNECTING MEANS SHALL SIMULTANEOUSLY DISCONNECT ALL CURRENT -CARRYING CONDUCTORS THAT ARE NOT SOLIDLY GROUNDED WHICH IT IS CONNECTED TO AND SHALL BE OPERABLE WITHOUT EXPOSING THE OPERATOR TO ANY ENERGIZED PARTS OF THE DISCONNECT. [NEC 690.15(D)] 9. ALL CONDUCTOR EXPOSED TO WEATHER SHALL BE LISTED AND IDENTIFIED FOR USE IN DIRECT SUNLIGHT. [NEC 310.10(D)] 10. THE MODULE CONDUCTORS MUST BE TYPE USE -2 OR LISTED FOR PHOTOVOLTAIC (PV) WIRE. [NEC 690.31(C)(1)] 11. PV SYSTEM DC CIRCUIT CONDUCTORS SHALL BE IDENTIFIED AT ALL TERMINATIONS, CONNECTIONS, AND SPLICE POINTS BY COLOR CODING, MARKING TAPE, TAGGING, OR OTHER APPROVED MEANS. [NEC 690.31(6)(1)] 12. ALL GROUNDED CONDUCTORS SHALL BE PROPERLY COLOR IDENTIFIED AS WHITE OR GRAY. [NEC 200.61 13. PV SYSTEM CONNECTED ON THE LOAD SIDE OF THE SERVICE DISCONNECTING MEANS OF THE OTHER SOURCE(S) AT ANY DISTRIBUTION EQUIPMENT ON THE PREMISES SHALL BE IN ACCORDANCE WITH NEC 705.12(A) (SUPPLY SIDE) AND 705.12(B) (LOAD SIDE). 14. EACH SOURCE CONNECTION SHALL BE MADE AT A DEDICATED CIRCUIT BREAKER OR FUSIBLE DISCONNECTING MEANS. [NEC 705.12(B)(1)] 15. THE SUM OF THE AMPERE RATING OF THE OVERCURRENT DEVICES IN CIRCUITS SUPPLYING POWER TO THE BUSBAR OR CONDUCTOR SHALL NOT EXCEED 120% OF THE RATING OF THE BUSBAR OR CONDUCTOR AND THE INTERCONNECTION POINT SHALL BE LOCATED AT THE OPPOSITE END OF THE BUSBAR AS THE PRIMARY POWER SOURCE. [NEC 705.12(B)(2)(3)(B)] 16. THE INTERCONNECTION POINT OF PRODUCTION EQUIPMENT SHALL BE CONNECTED TO THE SUPPLY SIDE OF THE GROUND -FAULT PROTECTION EQUIPMENT INSTALLED IN AC CIRCUITS AS REQUIRED ELSEWHERE IN THIS CODE, BUT SHALL BE PERMITTED TO BE MADE TO THE LOAD SIDE OF THE GROUND -FAULT PROTECTED EQUIPMENT PROVIDED THERE IS GROUND -FAULT PROTECTION FOR EQUIPMENT FROM ALL GROUND -FAULT CURRENT SOURCES. [NEC 705.32] 17. EQUIPMENT CONTAINING OVERCURRENT DEVICES IN CIRCUITS SUPPLYING POWER TO A BUS BAR OR CONDUCTOR SHALL BE MARKED TO INDICATE THE PRESENCE OF ALL SOURCES. (NEC 705.12(B)(3)] 18. CIRCUIT BREAKER, IF BACKFEED, SHALL BE SUITABLE FOR SUCH OPERATION. [NEC 705.12(B)(4)] 19. ALL THE NEC REQUIRED WARNING SIGNS, MARKINGS, AND LABELS SHALL BE POSTED ON EQUIPMENT AND DISCONNECTS PRIOR TO ANY INSPECTIONS TO BE PERFORMED BY THE BUILDING DEPARTMENT INSPECTOR. 20. METAL RACEWAYS, TYPE MC METAL -CLAD CABLE THAT COMPLIES WITH NEC 250.118(10) OR METALLIC ENCLOSURES ARE REQUIRED AS WIRING METHOD FOR INSIDE THE BUILDING FOR PV SYSTEM DC CIRCUITS. [NEC 690.31(G)] 21. FLEXIBLE, FINE -STRANDED CABLES SHALL BE TERMINATED ONLY WITH TERMINALS, LUGS, DEVICES OR CONNECTORS IN ACCORDANCE WITH NEC 110.14. [NEC 690.31(H)] 22. CONNECTORS SHALL BE OF LATCHED OR LOCKING TYPE. CONNECTORS THAT ARE READILY ACCESSIBLE AND OPERATING AT OVER 30 VOLTS DC OR 15 VOLTS AC SHALL REQUIRE TOOL TO OPEN AND MARKED "DO NOT DISCONNECT UNDER LOAD" OR "NOT FOR CURRENT INTERRUPTING". [NEC 690.33(C) & (E)(2)] 23. EQUIPMENT GROUNDING CONDUCTOR FOR PV SYSTEMS WITHOUT GROUND FAULT PROTECTION (GFP) AND INSTALLED ON NON-DWFI I IN(, UNIT MUST HAVE AMPACITY OF AT LEAST #10 AWG. 24. GROUNDING ELECTRODE CONDUCTOR WILL BE CONTINUOUS. [NEC 250.64(C)] 25. EQUIPMENT PROPOSED TO BE MOUNTED ON EXTERIOR WALLS ARE TO MAINTAIN CLEARANCE TO OPERABLE WINDOWS PER MANUFACTURERS RECOMMENDATION AND CODE. onth da�5'u� 0625 Pl n rd, Town of Yorktown N by N bar -- • -L. PI ning Board Chairman GENERAL CONDUCTOR INSULATION KEY LEGEND: - MODULES - EQUIPMENT - CONDUIT RUN - DRIVE WAY - PROPERTY LINE -SETBACK - OBSTRUCTIONS ABBREVIATIONS: AC - ALTERNATING CURRENT AWG - AMERICAN WIRE GAUGE AHJ - AUTHORITY HAVING JURISDICTION APP - APPROXIMATE AL - ALUMINUM CU - COPPER DC - DIRECT CURRENT (E) - EXISTING EMT - ELECTRICAL METALLIC TUBING Ili - ELECTRICAL PHASE IMC - INTERMEDIATE METAL CONDUIT (N) - NEW NEMA - NATIONAL ELECTRIC MANUFACTURERS ASSOCIATION NEC - NATIONAL ELECTRICAL CODE PVC - POLYVINYLCHLORIDE CONDUIT TYP - TYPICAL NOTE: ON THREE PHASE,HIGH LEG DELTA SYSTEMS,HIGH LEG MUST BE ORANGE, AS PER RFQUIRFD BY NFPA 70. sealed 03apr2025 mike@h2dc.com H2DC PLLC NY CoAk PB -082933 ELECTRICAL ONLY PRE CONSTRUCTION DRAWING SET ENGINEERING SCOPE OF WORK: 1. ILLUMINE INDUSTRIES INC. HAS ONLY PROVIDED DRAFTING SERVICES FOR THE PERMIT DRAWINGS. NO ACTUAL ENGINEERING WORK, ENGINEERING REVIEW OR ENGINEERING APPROVAL HAS BEEN CONDUCTED BY ILLUMINE INDUSTRIES INC UNLESS NOTED OTHERWISE. 2. WHEN A PROFESSIONAL ENGINEER APPROVES AND SEALS THE DESIGN FOR COMPONENTS OF THEIR RESPECTIVE DISCIPLINE (STRUCTURAL/ELECTRICAL) SHOWN ON THESE PERMIT DRAWINGS, HE/SHE: A. TAKES FULL DIRECT CONTROL OF THE ENGINEERED DESIGN B. IS GIVEN ACCESS TO PERSONALLY SUPERVISE AND RECTIFY ANY ASPECT OF THE ENGINEERED DESIGN C. HAS FULLY ACCEPTED RESPONSIBILITY FOR THE ENGINEERED DESIGN WARNING: IT IS A VIOLATION OF THE NYS EDUCATION LAW ARTICLE 145 FOR ANY PERSON, UNLESS HE IS ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS ITEM IN ANY WAY. FREEDOM SOLAR POWER 4801 FRIEDRICH W.SUITE 100 AUSTIN, TX 78744 P:512.640.3864 freedomsolarpower. com SYSTEM INFORMATION DC SYSTEM SIZE: 253.17kW AC SYSTEM SIZE: 200.00kW MODULES: (522)HANWHA QCELLS Q.PEA DUO XL-G1O.3/BFG 485W INVERTERS: (4)SOLAREDGE TECHNOLOGIES SE50KUS (120/208V, 3PH) OPTIMIZER: (264)SOLAREDGE P1101 POWER OPTIMIZER WIND SPEED:114MPH SNOW LOAD:30PSF MINIMUM TEMPERATURE: -15.80C MAXIMUM TEMPERATURE: 32.30C DC CONDUCTORS POSITIVE(UNGROUNDED) RFD BLACK NEGATIVE(UNGROUNDED) 120/208V OR 240V AC CONDUCTORS PHASE A BLACK PHASE B RED (SEE NOTE) PHASE C BLUE 480/277V AC CONDUCTORS PHASE A BROWN PHASE ORANGE PHASE C YELLOW NEUTRAL WHITE OR GREY GROUND GREEN OR BARE Cu LEGEND: - MODULES - EQUIPMENT - CONDUIT RUN - DRIVE WAY - PROPERTY LINE -SETBACK - OBSTRUCTIONS ABBREVIATIONS: AC - ALTERNATING CURRENT AWG - AMERICAN WIRE GAUGE AHJ - AUTHORITY HAVING JURISDICTION APP - APPROXIMATE AL - ALUMINUM CU - COPPER DC - DIRECT CURRENT (E) - EXISTING EMT - ELECTRICAL METALLIC TUBING Ili - ELECTRICAL PHASE IMC - INTERMEDIATE METAL CONDUIT (N) - NEW NEMA - NATIONAL ELECTRIC MANUFACTURERS ASSOCIATION NEC - NATIONAL ELECTRICAL CODE PVC - POLYVINYLCHLORIDE CONDUIT TYP - TYPICAL NOTE: ON THREE PHASE,HIGH LEG DELTA SYSTEMS,HIGH LEG MUST BE ORANGE, AS PER RFQUIRFD BY NFPA 70. sealed 03apr2025 mike@h2dc.com H2DC PLLC NY CoAk PB -082933 ELECTRICAL ONLY PRE CONSTRUCTION DRAWING SET ENGINEERING SCOPE OF WORK: 1. ILLUMINE INDUSTRIES INC. HAS ONLY PROVIDED DRAFTING SERVICES FOR THE PERMIT DRAWINGS. NO ACTUAL ENGINEERING WORK, ENGINEERING REVIEW OR ENGINEERING APPROVAL HAS BEEN CONDUCTED BY ILLUMINE INDUSTRIES INC UNLESS NOTED OTHERWISE. 2. WHEN A PROFESSIONAL ENGINEER APPROVES AND SEALS THE DESIGN FOR COMPONENTS OF THEIR RESPECTIVE DISCIPLINE (STRUCTURAL/ELECTRICAL) SHOWN ON THESE PERMIT DRAWINGS, HE/SHE: A. TAKES FULL DIRECT CONTROL OF THE ENGINEERED DESIGN B. IS GIVEN ACCESS TO PERSONALLY SUPERVISE AND RECTIFY ANY ASPECT OF THE ENGINEERED DESIGN C. HAS FULLY ACCEPTED RESPONSIBILITY FOR THE ENGINEERED DESIGN WARNING: IT IS A VIOLATION OF THE NYS EDUCATION LAW ARTICLE 145 FOR ANY PERSON, UNLESS HE IS ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS ITEM IN ANY WAY. FREEDOM SOLAR POWER 4801 FRIEDRICH W.SUITE 100 AUSTIN, TX 78744 P:512.640.3864 freedomsolarpower. com SYSTEM INFORMATION DC SYSTEM SIZE: 253.17kW AC SYSTEM SIZE: 200.00kW MODULES: (522)HANWHA QCELLS Q.PEA DUO XL-G1O.3/BFG 485W INVERTERS: (4)SOLAREDGE TECHNOLOGIES SE50KUS (120/208V, 3PH) OPTIMIZER: (264)SOLAREDGE P1101 POWER OPTIMIZER WIND SPEED:114MPH SNOW LOAD:30PSF MINIMUM TEMPERATURE: -15.80C MAXIMUM TEMPERATURE: 32.30C F(C ROJECT INFORMATION AME:CURRY HONDA YORKTOWN OM -41603) ADDRESS:3845 CROMPOND ROAD, YORKTOWN, NY 10598 41,291126,-73.851721 APN; 35.08-1-01 AH):NY-TOWN OF YORKTOWN UTILITY:CON EDISON PRN NUMBER: FMS -CU -2022 -877 :(ILLUMINE i GENERAL NOTES DRAFTED BY/QC'ED BY: THAMIZHARASAN G/MANISH A SCALE:AS NOTED REV:B DATE:03/26/2025 CS -01 M DATE r03/20212912024 DESCRIPTION REV O PERMIT PLAN A 6/2025 1 %D rl 00 d' M LM 0 O� V z U ..z W 3. N n ZOP, O1.- e -I OO Y W a cc N U. a < OW .� Qin Ch N J Q z z O It O Qac Z O Ou _ I^ d• OD M U F(C ROJECT INFORMATION AME:CURRY HONDA YORKTOWN OM -41603) ADDRESS:3845 CROMPOND ROAD, YORKTOWN, NY 10598 41,291126,-73.851721 APN; 35.08-1-01 AH):NY-TOWN OF YORKTOWN UTILITY:CON EDISON PRN NUMBER: FMS -CU -2022 -877 :(ILLUMINE i GENERAL NOTES DRAFTED BY/QC'ED BY: THAMIZHARASAN G/MANISH A SCALE:AS NOTED REV:B DATE:03/26/2025 CS -01 REVISION DATE r03/20212912024 DESCRIPTION REV PERMIT PLAN A 6/2025 1 INVERTER UPDATE B F(C ROJECT INFORMATION AME:CURRY HONDA YORKTOWN OM -41603) ADDRESS:3845 CROMPOND ROAD, YORKTOWN, NY 10598 41,291126,-73.851721 APN; 35.08-1-01 AH):NY-TOWN OF YORKTOWN UTILITY:CON EDISON PRN NUMBER: FMS -CU -2022 -877 :(ILLUMINE i GENERAL NOTES DRAFTED BY/QC'ED BY: THAMIZHARASAN G/MANISH A SCALE:AS NOTED REV:B DATE:03/26/2025 CS -01 SITE PLAN: DC SYSTEM SIZE: 253.17kW, AC SYSTEM SIZE: 200.00kW CROMPO/vD ROgD 192'-l" I I In r nTv . Tl .l ITY TRANSFORMER (POLE MOUNTED) SETBACK (TYP.) )VOLTAIC ARRAYS ON THE ROOF WARNING: IT IS A VIOLATION OF THE NYS EDUCATION LAW ARTICLE 145 FOR ANY PERSON, UNLESS HE IS ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS ITEM IN ANY WAY. sealed 03apr2025 mike@h2dc.com H2DC PLLC NY CoA#: PB -082933 ELECTRICAL ONLY PRE CONSTRUCTION DRAWING SET FREEDOM" SOLAR POWER 4801 FRIEDRICH LN.SUITE 100 AUSTIN, TX 78744 P:512.640.3864 freedomsolarpower. com SYSTEM INFORMATION DC SYSTEM SIZE: 253.17kW AC SYSTEM SIZE: 200.00kW MODULES: (522)HANWHA QCELLS Q.PEA DUO XL-G10.3/BFG 485W INVERTERS: (4)SOLAREDGE TECHNOLOGIES SE50KUS (120/208V,3PH) OPTIMIZER: (264)SOLAREDGE P1101 POWER OPTIMIZER WIND SPEED:114MPH SNOW LOAD:30PSF MINIMUM TEMPERATURE: -15.8°C MAXIMUM TEMPERATURE: 32.3°C (E) MAIN SERVICE DISCONNECT (INSIDE THE ELECTRICAL ROOM) DRI VF REVISION DATE WqY 592'-10" (E) MAIN DISTRIBUTION PANEL (INSIDE THE ELECTRICAL ROOM) 02/29/2024 PERMIT PLAN A 03/76/7075 INVFRTER UPDATE B M (E) UTILITY METER W/CT CABINET (INSIDE THE ELECTRICAL ROOM) 0 0 74 Go d' Ln � o Oz 330' 23'-2" CRO MPo W Z N Z NO n 0 n RO O Y Ln 00 O 0 a I+1 oc a0�aN O O ° " qy 0,04, J 0 0,4 a 0. oRj�F Z o O U _ In qy 00 � M 89'-2" U PARKING SPACE (TYP.) SCALE: 1"=40'-O" 611'-8" 192'-9" 104'-6" Resolution Number 2-,5 - 3 Date L2 11 z c, ZS PROJECT INFORMATION NAME:CURRY HONDA YORKTOWN (COM -41603) ADDRESS:3845 CROMPOND ROAD, YORKTOWN, NY 10598 41.291126,-73.851721 APN: 35.08-1-01 AH7: NY -TOWN OF YORKTOWN UTILIiY:CON EDISON PRN NUMBER: FMS -CU -2022-877 :(�JILLUMINE it SITE PLAN DRAFTED BY/QC'ED BY: THAMIZHARASAN G/MANISH A 7�T SCALE:AS NOTED REV:B 1V DATE:03/26/2025 A-01 REVISION DATE DESCRIPTION REV 02/29/2024 PERMIT PLAN A 03/76/7075 INVFRTER UPDATE B PROJECT INFORMATION NAME:CURRY HONDA YORKTOWN (COM -41603) ADDRESS:3845 CROMPOND ROAD, YORKTOWN, NY 10598 41.291126,-73.851721 APN: 35.08-1-01 AH7: NY -TOWN OF YORKTOWN UTILIiY:CON EDISON PRN NUMBER: FMS -CU -2022-877 :(�JILLUMINE it SITE PLAN DRAFTED BY/QC'ED BY: THAMIZHARASAN G/MANISH A 7�T SCALE:AS NOTED REV:B 1V DATE:03/26/2025 A-01 ENLARGED SITE PLAN: ARRAY QUANTITY MODULE TILT AZIMUTH ARRAY -01 81 10" 2940 ARRAY -02 90 10" 2940 ARRAY -03 42 100 1140 ARRAY -04 114 100 1140 ARRAY -05 39 100 2940 ARRAY -06 76 100 1140 ARRAY -07 80 100 1140 TOTAL MODULES 522 6' FIRE SETBACKS (TYP.) SCALE: 1/ 16" =1'-0" (E) UTILITY TRANSFORMER (POLE MOUNTED) c_ I SERVICE DISCONNECT (INSIDE THE ELECTRICAL ROOM) I DISTRIBUTION PANEL THE ELECTRICAL ROOM) ITY METER W/CT CABINET (INSIDE THE ELECTRICAL ROOM) kUGE MONITORING UNIT (EXTERIOR WALL OF THE BUILDING) DISCONNECT (EXTERIOR WALL OF THE BUILDING) WARNING: IT IS A VIOLATION OF THE NYS EDUCATION LAW ARTICLE 145 FOR ANY PERSON, UNLESS HE IS ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS ITEM IN ANY WAY. sealed 03apr2025 mike@h2dc.com H2DC PLLC NY CoAk PB•082933 ELECTRICAL ONLY PRE CONSTRUCTION DRAWING SET tt= = FREEDOM" SOLAR POWER 4801 FRIEDRICH LN.SUITE 100 AUSTIN, TX 78744 P:512.640.3864 freedomsolarpower. com SYSTEM INFORMATION DC SYSTEM SIZE: 253.17kW AC SYSTEM SIZE: 200.00kW MODULES: (522)HANWHA QCELLS Q.PEA DUO XL-G10.3/BFG 485W INVERTERS: (4)SOLAREDGE TECHNOLOGIES SE50KUS (120/208V, 3PH) OPTIMIZER: (264)SOLAREDGE P1101 POWER OPTIMIZER WIND SPEED:114MPH SNOW LOAD:30PSF MINIMUM TEMPERATURE: -15.80C MAXIMUM TEMPERATURE: 32.3°C TRE SETBACKS (TYP.) APP OVEI D Resolution Number 13 Date REVISION k290312612025 ATE DESCRIPTION REV /2024 PERMIT PLAN A I INVERTER UPDATE B PROJECT INFORMATION NAME:CURRY HONDA YORKTOWN (COM -41603) ADDRESS:3845 CROMPOND ROAD, YORKTOWN, NY 10598 41.291126, -73.851721 APN: 35.08-1-01 AHJ:NY-TOWN OF YORKTOWN UTILITY:CON EDISON PRN NUMBER: FMS -CU -2022-877 :('ILLUMINE i ENLARGED SITE PLAN IDRAFTED BY/QC'ED BY: I THAMIZHARASAN G/MANISH A SCALE:AS NOTED I REV:B DATE:03/26/2025 I A-02 M O �O -OVOLTAIC ARRAYS ON THE ROOF 00 DUIT RUN i L0 14 O} UZ LU Z Zoe O InC OOM 00 a OI.L aN GC O Q >- fV Z O Qac Z O CCU AC ACCUMULATION PANEL(EXTERIOR WAI I OF THE BUILDING) _ U) (N) DC GUTTER BOX(EXTERIOR WALL OF THE BUILDING) M (N) PV INVERTER - 04(EXTERIOR WALL OF THE BUILDING) (N) PV INVERTER - 03(EXTERIOR WALL OF THE BUILDING) M (N) PV INVERTER - 02(EXTERIOR WALL OF THE BUILDING) U (N) PV INVERTER - 01(EXTERIOR WALL OF THE BUILDING) TRE SETBACKS (TYP.) APP OVEI D Resolution Number 13 Date REVISION k290312612025 ATE DESCRIPTION REV /2024 PERMIT PLAN A I INVERTER UPDATE B PROJECT INFORMATION NAME:CURRY HONDA YORKTOWN (COM -41603) ADDRESS:3845 CROMPOND ROAD, YORKTOWN, NY 10598 41.291126, -73.851721 APN: 35.08-1-01 AHJ:NY-TOWN OF YORKTOWN UTILITY:CON EDISON PRN NUMBER: FMS -CU -2022-877 :('ILLUMINE i ENLARGED SITE PLAN IDRAFTED BY/QC'ED BY: I THAMIZHARASAN G/MANISH A SCALE:AS NOTED I REV:B DATE:03/26/2025 I A-02 MODUt F ATTACHMENT DETAIL- 8- SOLAR STACK MOUNT / PV MODULE POLYS M TO MEP ET AMB 160 ADHESIVE & E PRIMER MID -CLAMP AND END -CLAMP ANATOMY F-- MID CLAMP LY�T.i Tr�e7fe7 r3 { 6 \ Rel Y END CLAMP MODULE PHOTOVOLTAIC ARRAYS ON ROOF 6' FIRE SETBACKS(TYP.) ARRAY MP -04 ❑ ARRAY MP -05 ARRAY MP -07 —\ SOLAR STACK ROOF' GROUND CONDUTOR ASSEMBLY EQUIPMENT GROUND CONDUCTOR LAY IN EQUIPMENT GROUND CONDUCTOR AND TORQUE BOLT TO 7FT-LB 110 N -M. SOLAR STACK'S COMPONENTS DEAD LOAD CALCULATIONS BOM ROOF PITCH QUANTITY LBS/UNIT TOTAL WEIGHT (LBS) MODULES MP -01 522 64.2 33512.40 MID -CLAMP TPO 994 0.050 49.70 END -CLAMP 90 100 0.050 5.00 OPTIMIZER CLIP 262 1.17 306.54 SOLAR STACK 1094 T1,87 2045.78 TOTAL WEIGHT OF THE SYSTEM (LBS) 35919.42 TOTAL ARRAY AREA ON THE ROOF (SQ. FT.) 12991.71 WEIGHT PER SQ. FT.(LBS) MP -05 2.76 WEIGHT PER BLOCK (LBS) 970.65 32.83 SITE INFORMATION - WIND SPEED: 114 MPH, EXPOSURE: C AND SNOW LOAD: 30 PSF SR. NO AZIMUTH ROOF PITCH NO.OF MODULES ARRAY AREA (SQ. FT.) ROOF TYPE ATTACHMENT MP -01 2940 100 81 2015.96 TPO 8" SOLAR STACK MOUNT MP -02 2940 100 90 2239.95 TPO 8" SOLAR STACK MOUNT MP -03 1140 100 42 1045.31 TPO 8" SOLAR STACK MOUNT MP -04 1140 100 114 2837.27 TPO 8" SOLAR STACK MOUNT MP -05 2940 100 39 970.65 TPO 8" SOLAR STACK MOUNT MP -06 1140 100 76 1891.51 TPO 8" SOLAR STACK MOUNT MP -07 1140 100 80 1991.07 TPO 8" SOLAR STACK MOUNT GENERAL STRUCTURAL NOTES 1.ALL EQUIPMENTS SHALL BE INSTALLED PER MANUFACTURER INSTALLATION AND OPERATIONS MANUAL REQUIREMENTS. 2.PRIOR TO COMMENCEMENT OF WORK OR FABRICATION OF COMPONENTS, THE CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS, DIMENSIONS,AND ELEVATIONS OF THE EXISTING CONSTRUCTION. CONTRACTOR SHALL NOTIFY ENGINEER OF ANY DISCREPANCIES BETWEEN I HE FIELD -VERIFIED CONDITIONS, DIMENSIONS,AND ELEVATION AND THOSE INDICATED ON THE DRAWINGS. 3.ALL THE CONSTRUCTION SHALL COMPLY WITH REQUIREMENTS OF 2020 EDITION OF THE NEW YORK BUILDING CODE. SOLAR RACK COMPONENTS: 1. FOLLOW MANUFACTURER'S INSTALLATION FOR INSTALLATION OF THE SOLAR COM PONENTS,INCLUDING MODULE CLAMPS,L-FEET, BRACKETS MECIIANICAL ATTACHMENTS,AND HARDWARE. STRUCTURAL NOTES: ROOF MEMBRANE SHALL BE CONFIRMED TO BE INSTALLED AS FULLY ADHERED MEMBRANE PRIOR TO INSTALLATION OF SOLAR STACK ATTACHMENTS. ARRAY MP -02 8" SOLAR STACK /—ARRAY MP -01 WARNING: IT IS A VIOLATION OF THE NYS EDUCATION LAW ARTICLE 145 FOR ANY PERSON, UNLESS HE IS ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS ITEM IN ANY WAY. ARRAY MP -0.; OF NE{ — IOR Jp,I,fOip'� 4 I * ( - V �v - * 2 2 JF���OF x542 P j ESSVON 04/03/2025 STRUCTURAL ONLY 09 ATP71=1 D Resolution Number 2-.5 I- . bate la I of 1 2=0-)-5 FREEDOM" SOLAR POWER 4801 FRIEDRICH W.SUIfE 100 AUSTIN, TX 78744 P:512.640,3864 freedomsolarpow er. com SYSTEM INFORMATION DC SYSTEM SIZE: 253.17kW AC SYSTEM SIZE: 200.00kW MODULES: (522)HANWHA QCELLS Q.PEA DUO XL-G10.3/BFG 485W INVERTERS: (4)SOLAREDGE TECHNOLOGIES SE50KUS (120/208V, 3PH) OPTIMIZER: (264)SOLAREDGE P1101 POWER OPTIMIZER WIND SPEED:114MPH SNOW I..OAD:30PSF MINIMUM TEMPERATURE: -15.80C MAXIMUM TEMPERATURE: 32.30C 9'—I8" O to �00 9'-8" 23 —5 �1; — o Or 161-511— U A m U m LU [no O Be in �' IIyy11 , Iy, w `F' ED (In ED ® ® , � Die7G II I� ED 116 a to On I Be so 1 I' > 0 Yo� a GC a N GC O W,4 Q °� fig I (go 0 ED so ED f 0 ED on to Go anool Qac file Z0 O Ov as BE END 2Ln I aIle Ile1 00M I I U 6 13' _ 23'-3" r 11 9 —9 -- I I ! .Q t!! I d9 ,1yI0 ap [i OR m Q1 igo 69 m II !t' t I] r [i. Ifl 0 0DID 23'-3" ��Go ON I I q. I— 16'-5" 3-9 -- — ❑ 5' - 5' 3'-7" 42'-111 0 00 18 go me 1# 148'-6"-- I I Big no 00 1 goLIE; I m I 81! 13'-11" 148'-6" (� T. ARRAY MP -0 13'-7" 61 9'-6" I 010 In ED go I - -- - in t G an 111 us o Im ED on I as BID an ED m -1 ED go OR Go so t4l II ff II CIO li1 go I I I I I I I I I I 19 to. as no a 1 s I a; E 0 19 c I D I B 10 1 D E I E 0 1 D E I on 0 B I to I I m 10 6 l` --- — _�'—81-211 — 19 00 1 In I a LI 0 09'-7" 9'-2" 9'-2" ARRAY MP -0.; OF NE{ — IOR Jp,I,fOip'� 4 I * ( - V �v - * 2 2 JF���OF x542 P j ESSVON 04/03/2025 STRUCTURAL ONLY 09 ATP71=1 D Resolution Number 2-.5 I- . bate la I of 1 2=0-)-5 FREEDOM" SOLAR POWER 4801 FRIEDRICH W.SUIfE 100 AUSTIN, TX 78744 P:512.640,3864 freedomsolarpow er. com SYSTEM INFORMATION DC SYSTEM SIZE: 253.17kW AC SYSTEM SIZE: 200.00kW MODULES: (522)HANWHA QCELLS Q.PEA DUO XL-G10.3/BFG 485W INVERTERS: (4)SOLAREDGE TECHNOLOGIES SE50KUS (120/208V, 3PH) OPTIMIZER: (264)SOLAREDGE P1101 POWER OPTIMIZER WIND SPEED:114MPH SNOW I..OAD:30PSF MINIMUM TEMPERATURE: -15.80C MAXIMUM TEMPERATURE: 32.30C DATE DESCRIPTION qA 02/29/2024 PERMIT PLAN 10:3/26/2025 INVERTER UPDATE PROJECT INFORMATION NAME:CURRY HONDA YORKTOWN (COM -41603) ADDRESS:3845 CROMPOND ROAD, YORKTOWN, NY 10598 41.291126,-73.851721 APN:35.08-1-01 AHJ:NY-TOWN OF YORKTOWN UTILTIY:CON EDISON PRN NUMBER: FMS -CU -2022-877 :(ILLUMINE i STRUCTURAL DETAILS & ARRAY PLAN IDRAFTED BY/QC'ED BY: I THAMIZHARASAN G/MANISH A SCALE:AS NOTED I REV:8 DATE:03/26/2025 I S-01 M O to �00 �cn On o Or U U z LU Z0N O In x 00 > 0 Yo� a GC a N GC O W,4 Q °� z O Qac Z0 O Ov 2Ln 00M U DATE DESCRIPTION qA 02/29/2024 PERMIT PLAN 10:3/26/2025 INVERTER UPDATE PROJECT INFORMATION NAME:CURRY HONDA YORKTOWN (COM -41603) ADDRESS:3845 CROMPOND ROAD, YORKTOWN, NY 10598 41.291126,-73.851721 APN:35.08-1-01 AHJ:NY-TOWN OF YORKTOWN UTILTIY:CON EDISON PRN NUMBER: FMS -CU -2022-877 :(ILLUMINE i STRUCTURAL DETAILS & ARRAY PLAN IDRAFTED BY/QC'ED BY: I THAMIZHARASAN G/MANISH A SCALE:AS NOTED I REV:8 DATE:03/26/2025 I S-01 STRINGING MAP: INVERTER 1, 50kW INVERTER 2, 5OkW UNIT 01 UNIT 01 STRING MOD. QTY. OPT. QTY STRING MOD. QTY. OPT. QTY 1-1-1 22 11 2-1-1 22 11 1-1-2 22 11 2-1-2 22 11 UNIT 02 UNIT 02 STRING MOD. QTY. OPT.QTY STRING MOD. QTY. OPT.QTY 1-2-1 21 it 2-2-1 22 it 1-2-2 22 11 2-2-2 21 it UNIT 03 UNIT 03 STRING MOD. QTY. OPT.QTY STRING MOD. QTY. OPT.QTY 1-3-1 22 11 2-3-1 21 11 1-3-2 22 11 2-3-2 22 11 INVERTER 01 TOTAL 131 66 INVERTER 02 TOTAL 130 66 INVERTER 3, 5OkW INVERTER 4, 50kW UNIT 01 UNIT 01 STRING MOD. QTY. OPT. QTY STRING MOD. QTY. OPT. QTY 3-1-1 22 11 4-1-1 22 11 3-1-2 22 11 4-1-2 22 11 UNIT 02 UNIT 02 STRING MOD. QTY. OPT.QTY STRING MOD. QTY. OPT.QTY 3-2-1 22 11 4-2-1 22 11 3-2-2 21 11 4-2-2 21 11 UNIT 03 UNIT 03 STRING MOD. QTY. OPT.QTY STRING MOD. QTY. OPT.QTY 3-3-1 22 11 4-3-1 21 11 3-3-2 22 11 4-3-2 22 11 INVERTER 03 TOTAL 131 66 INVERTER 04 TOTAL 130 66 IGRAND TOTAL 522 264 WIRING AND WIRING METHODS: 1. EXPOSED PV SOLAR MODULE WIRING AND PV SOURCE CIRCUITS TO BE UV RESISTANT 2,000V PV WIRE, 90° C, AND RATED FOR WET CONDITIONS. 2. ALL EXPOSED CABLES, SUCH AS MODULE LEADS SHALL BE SECURED IN A NEAT WORKMAN LIKE MANNER TO PREVENT CHAFFING, SWINGING, AND EXCEEDING MINIMUM BEND RADIUS WITH PROPER MECHANICAL SUNLIGHT RESISTANT MEANS AND ROUTED TO AVOID DIRECT EXPOSURE TO SUNLIGHT AT ALL TIMES. 3. ALL FIELD WIRING THAT IS NOT COLOR CODED SHALL BE TAGGED AT BOTH ENDS WITH PERMANENT WIRE MARKERS TO IDENTIFY POLARITY AND GROUND. 4. FLEXIBLE METAL CONDUIT IS SUITABLE FOR INSTALLATION IN DRY LOCATIONS. SHOULD 1T BE EMPLOYED, SUPPORTS WILL BE NO MORE THAN 12 INCHES FROM BOXES (JUNCTION BOX, CABINETS OR CONDUIT FITTING) AND NO MORE THAN 48 INCHES APART. 5. LIQUID TIGHT FLEXIBLE METAL AND NON-METALLIC CONDUIT IS SUITABLE FOR INSTALLATION IN WET AND DRY LOCATIONS. SHOULD IT BE EMPLOYED, SUPPORTS WILL BE NO MORE THAN 12 INCHES FROM BOXES (JUNCTION BOX, CABINETS, OR CONDUIT FITTING) AND NO MORE THAN 36 INCHES APART. 6. PVC CONDUIT AND FITTINGS SHALL NOT BE USED ON ROOFTOP CONDITIONS OR EXPOSED TO DIRECT SUNLIGHT.WHEN USED IN ACCEPTABLE LOCATION CONDUIT SHALL BE SCHEDULE 80 UV RESISTANT UNLESS NOTED OTHERWISE. 7. FUSES AND WIRES SUBJECT TO TEMPERATURES CONDITIONS GREATER THAN 100°F OR TRANSFORMER INRUSH CURRENT SHALL BE SIZED ACCORDINGLY. 8. THE PHOTOVOLTAIC SOURCE CIRCUITS AND PHOTOVOLTAIC OUTPUT CIRCUITS OF THIS PROPOSED SOLAR SYSTEM SHALL NOT BE CONTAINED IN THE SAME RACEWAY CABLE TRAY, CABLE, OUTLET BOX, JUNCTION BOX, OR SIMILAR FITTING AS FEEDERS OR BRANCH CIRCUITS OF OTHER SYSTEMS UNLESS THE CONDUCTORS OF THE DIFFERENT SYSTEMS ARE SEPARATED BY A PARTITION OR ARE CONNECTED TOGETHER. 9. ALL TERMINATIONS SHALL HAVE ANTI -OXIDANT COMPOUND AND BE TORQUED PER DEVICE LISTING, OR MANUFACTURER'S RECOMMENDATIONS. 10. SPLIT BOLTS /SPLICES / CONNECTORS ARE PERMITTED ON THE AC CONDUCTORS AND SHALL BE INSULATED WITH APPROVE[--) MEANS. SPLICES ON THE DC CONDUCTORS IS NOT PERMITTEDIN ANY LOCATION. 11.NO PVC CONDUIT ALLOWED ON ROOF, UNLESS OPEN ENDED WIRE MANAGEMENT <10'. STRING ID LEGEND STR 1-1-1(X) \_# OF MODULES STRING ID UNIT #(1,2,3) INVERTER ID# SCALE: 1/16"=1'-0" PHOTOVOLTAIC ARRAYS ON ROOF (N) PV INVERTER - 01 TO 04 (EXTERIOR WALL OF THE BUILDING) DC GUTTER BOX (EXTERIOR WALL OF THE BUILDING) (N) AC ACCUMULATION PANEL (EXTERIOR WALL OF THE BUILDING) WARNING: IT IS A VIOLATION OF THE NYS EDUCATION LAW ARTICLE 145 FOR ANY PERSON, UNLESS HE IS ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS ITEM IN ANY WAY. n M 3-2-2(21). DESCRIPTION REV O PERMIT PLAN A ,. 1-3-1(22) m - I - - U1 U1 4-3-2(22) Ci L 1-3-2(22) 3-3-1(22) F_ U z U z Lu n ZOO B 8 3 - [ri 2-1-2(22) O 00 4-2-2(21) r*h I TIT 2-1-1(22) >0Yo� PHOTOVOLTAIC ARRAYS ON ROOF (N) PV INVERTER - 01 TO 04 (EXTERIOR WALL OF THE BUILDING) DC GUTTER BOX (EXTERIOR WALL OF THE BUILDING) (N) AC ACCUMULATION PANEL (EXTERIOR WALL OF THE BUILDING) WARNING: IT IS A VIOLATION OF THE NYS EDUCATION LAW ARTICLE 145 FOR ANY PERSON, UNLESS HE IS ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS ITEM IN ANY WAY. n M 3-2-2(21). DESCRIPTION REV O PERMIT PLAN A ,. - - B I 00 - U1 U1 4-3-2(22) Ci L O 3-3-1(22) F_ PHOTOVOLTAIC ARRAYS ON ROOF (N) PV INVERTER - 01 TO 04 (EXTERIOR WALL OF THE BUILDING) DC GUTTER BOX (EXTERIOR WALL OF THE BUILDING) (N) AC ACCUMULATION PANEL (EXTERIOR WALL OF THE BUILDING) WARNING: IT IS A VIOLATION OF THE NYS EDUCATION LAW ARTICLE 145 FOR ANY PERSON, UNLESS HE IS ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS ITEM IN ANY WAY. (EXTERIOR WALL OF THE BUILDING) sealed 03apr2025 mike@h2dc.com H2DC PLLC NY COA#: PB -082933 ELECTRICAL ONLY PRE CONSTRUCTION DRAWING SET FREEDOM'' SOLAR POWER 1801 FRIEDRICH W.SUITE 100 AUSTIN, TX 78744 P:512.640.3864 freed o mso I a rpower. com SYSTEM INFORMATION DC SYSTEM SIZE: 253.17kW AC SYSTEM SIZE: 200.00kW MODULES: (522)HANWHA QCELLS Q.PEA DUO XL-G10.3/BFG 485W INVERTERS: (4)SOLAREDGE TECHNOLOGIES SE50KUS (120/208V, 3PH) OPTIMIZER: (264)SOLAREDGE P1101 POWER OPTIMIZER WIND SPEED:114MPH SNOW LOAD:30PSF MINIMUM TEMPERATURE: -15.8°C MAXIMUM TEMPERATURE: 32.3°C n M ,-r71 DESCRIPTION REV O PERMIT PLAN A 1 %D I 00 - U1 U1 4-3-2(22) Ci L O 4-3-1(21) F_ U z U z Lu n ZOO B 8 3 - [ri E, O 00 4-2-2(21) r*h I TIT >0Yo� (EXTERIOR WALL OF THE BUILDING) sealed 03apr2025 mike@h2dc.com H2DC PLLC NY COA#: PB -082933 ELECTRICAL ONLY PRE CONSTRUCTION DRAWING SET FREEDOM'' SOLAR POWER 1801 FRIEDRICH W.SUITE 100 AUSTIN, TX 78744 P:512.640.3864 freed o mso I a rpower. com SYSTEM INFORMATION DC SYSTEM SIZE: 253.17kW AC SYSTEM SIZE: 200.00kW MODULES: (522)HANWHA QCELLS Q.PEA DUO XL-G10.3/BFG 485W INVERTERS: (4)SOLAREDGE TECHNOLOGIES SE50KUS (120/208V, 3PH) OPTIMIZER: (264)SOLAREDGE P1101 POWER OPTIMIZER WIND SPEED:114MPH SNOW LOAD:30PSF MINIMUM TEMPERATURE: -15.8°C MAXIMUM TEMPERATURE: 32.3°C IPRO]ECT INFORMATION I NAME:CURRY HONDA YORKTOWN (COM -41603) ADDRESS:3845 CROMPOND ROAD, YORKTOWN, NY 10598 41.291126,-73.851721 APN: 35.08-1-01 AH3:NY-TOWN OF YORKTOWN UTILITY:CON EDISON PRN NUMBER: FMS -CU -2022-877 ii(.6. ILLUMINE it STRINGING MAP IDRAFTED BY/QC'ED BY: I THAMIZHARASAN G/MANISH A SCALE:AS NOTED I REV:B DATE:03/26/2025 I L 01 n M DATE 103/26/2025 DESCRIPTION REV O PERMIT PLAN A 1 %D T4 00 U1 U1 Ci L O F_ U z U z Lu n ZOO 3 Y In O 00 0 rri >0Yo� a oc o O�� a>— O Q 0. N Z0 0 Ou 2In It �(n M U IPRO]ECT INFORMATION I NAME:CURRY HONDA YORKTOWN (COM -41603) ADDRESS:3845 CROMPOND ROAD, YORKTOWN, NY 10598 41.291126,-73.851721 APN: 35.08-1-01 AH3:NY-TOWN OF YORKTOWN UTILITY:CON EDISON PRN NUMBER: FMS -CU -2022-877 ii(.6. ILLUMINE it STRINGING MAP IDRAFTED BY/QC'ED BY: I THAMIZHARASAN G/MANISH A SCALE:AS NOTED I REV:B DATE:03/26/2025 I L 01 REVISION DATE 103/26/2025 DESCRIPTION REV 02/29/2024 PERMIT PLAN A 1 INVERTER UPDATE B IPRO]ECT INFORMATION I NAME:CURRY HONDA YORKTOWN (COM -41603) ADDRESS:3845 CROMPOND ROAD, YORKTOWN, NY 10598 41.291126,-73.851721 APN: 35.08-1-01 AH3:NY-TOWN OF YORKTOWN UTILITY:CON EDISON PRN NUMBER: FMS -CU -2022-877 ii(.6. ILLUMINE it STRINGING MAP IDRAFTED BY/QC'ED BY: I THAMIZHARASAN G/MANISH A SCALE:AS NOTED I REV:B DATE:03/26/2025 I L 01 GROUND LUG DETAIL: TIN PLATED COPPER LUG , LAY IN TYPE RATED FOR DIRECT BURIEL ILSCO CBL-4DBT OR EQUIV BARE TINNED COPPER WIRE CONNECTION SIZED PER NEC TABLE 250.122 rPV MODULE OR RACKING LAY IN LUGS ATTACHED USING THE BOLT WITH SERRATED NUT—/FOLLOWING STAINLESS STEEL HARDWARE OR STAR LOCK WASHER BOLT: 1"L, #10-32,5/16" HEX HEAD NUT: #10,5/16" HEX HEAD WASHERS: STAR WASHER ON EACH SIDE CONDUIT WALL ANCHORING: ELECTRICAL CONDUIT ROUTE HORIZONTALLY OR VERTICALLY C 1-5/8" UNISTRUT CHANNI ANCHORED TO STRUCTURE USII` FASTENER SPECIFICALLY INTENDE FOR THE WAI CONDUIT STRAP ELECTRICAL CONDUIT BUILDING WALL CONDUIT BODY GROUNDING DETAIL: CONTIN"^"r rn^"^'^ STRIP TYPICAL DURA -BLOCK CONDUIT SUPPORT DETAIL: ROOF ELECTRICAL CONDUIT DURA BLOCK ROOFTOP SUPPORT AT EVERY 10'-0" OF CONDUIT SLIP SHEET WARNING: IT IS A VIOLATION OF THE NYS EDUCATION LAW ARTICLE 145 FOR ANY PERSON, UNLESS HE IS ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS ITEM IN ANY WAY. NOTE: DETAIL DRAWINGS ARE FOR REFERENCE ONLY API1'r," VM3) Resolution Number. 2S 13 Date i��jT2� Z_ GROUNDING - SEE ELECTRICAL DIAGRAM AND ELECTRICAL DETAILS FOR MORE GROUNDING INFORMATION: l.ONLY ONE CONNECTION TO DC CIRCUITS AND AC CIRCUITS WILL BE USED FOR SYSTEM GROUNDING (REFERENCED TO THE SAME POINT). 2.EQUIPMENT GROUNDING CONDUCTORS AND SYSTEM GROUNDING ELECTRODE CONDUCTORS WILL HAVE AS SHORT A DISTANCE TO THE GROUNDING CONNECTION POINT AS PRACTICABLE AND A MINIMUM NUMBER OF TURNS. 3.T0 ENSURE PROPER GROUNDING, NON-CURRENT CARRYING METAL PARTS SHALL BE INSTALLED, NOTING THAT PAINT AND FINISH SHALL BE PROPERLY REMOVED WHERE IT MAY INSULATE AN ENCLOSURES BONDING CONNECTION. APPLY NO -LOX OR OTHER SIMILAR ANTI -OXIDANT COMPOUND TO EXPOSED SURFACES. 4.THE CONNECTION TO THE MODULE OF THE PROPOSED SOLAR ELECTRIC SYSTEM SHALL BE SO ARRANGED THAT REMOVAL OF A MODULE FROM THE PHOTOVOLTAIC SOURCE CIRCUIT DOES NOT INTERRUPT A GROUND TO ANOTHER PHOTOVOLTAIC SOURCE CIRCUIT. 5.GROUNDING SYSTEM COMPONENTS SHALL BE APPROVED FOR THEIR PURPOSE, INCLUDING BUT NOT LIMITED TO GROUND RODS, GROUNDING LUGS, GROUNDING CLAMPS, ETC. GROUNDING DEVICES EXPOSED TO THE ENVIRONMENT SHALL BE RATED FOR DIRECT BURIAL. 6.UNDERGROUND OR INACCESSIBLE CONNECTIONS OF GROUNDING CONDUCTORS SHALL ONLY BE MADE VIA EXO-THERMIC WELDS. THE USE OF MECHANICAL CONNECTIONS ARE ACCEPTABLE FOR ACCESSIBLE ABOVE GROUND LOCATIONS. 7.ALL METALLIC CONDUITS SHALL BE INSTALLED AND TERMINATED WITH INSULATED GROUND BUSHINGS. � Nk FREEDOM'" SOLAR POWER 1801 FRIEDRICH LN.SUITE 100 AUSTIN, TX 78741 P: 512.640.3864 freedo msolarpower. com SYSTEM INFORMATION DC SYSTEM SIZE: 253.17kW AC SYSTEM SIZE: 200.00kW MODULES: (522)HANWHA QCELLS Q.PEAI< DUO XL-G10.3/BFG 485W INVERTERS: (4)SOLAREDGE TECHNOLOGIES SE50KUS (120/208V,3PH) OPTIMIZER: (264)SOLAREDGE P1101 POWER OPTIMIZER WIND SPEED:114MPH SNOW LOAD:30PSF MINIMUM TEMPERATURE: -15.8°C MAXIMUM TEMPERATURE: 32.3°C PROJECT INFORMATION NAME:CURRY HONDA YORKTOWN (COM -41603) ADDRESS:3845 CROMPOND ROAD, YORKTOWN, NY 10598 41.291126,-73.851721 APN: 35.08-1-01 AHJ: NY -TOWN OF YORKTOWN UTILITY:CON EDISON PRN NUMBER: FMS -CU -2022-877 :('ILLUMINE ELECTRICAL MOUNTING DETAILS DRAFTED BY/QC'ED BY: THAMIZHARASAN G/MANISH A SCALE:AS NOTED I REV:B DATE:03/26/2025 I E-02 REVISION DATE DESCRIPTION REV M PERMIT PLAN A 03/26/2025 O tD V -1w in o O} F- U z U ., . z LU z0N n O �Y� a O0M 00 > 0 aUL.oc o O a, Q fV z0,4 O Z0 OU 2Ln T 00M D U PROJECT INFORMATION NAME:CURRY HONDA YORKTOWN (COM -41603) ADDRESS:3845 CROMPOND ROAD, YORKTOWN, NY 10598 41.291126,-73.851721 APN: 35.08-1-01 AHJ: NY -TOWN OF YORKTOWN UTILITY:CON EDISON PRN NUMBER: FMS -CU -2022-877 :('ILLUMINE ELECTRICAL MOUNTING DETAILS DRAFTED BY/QC'ED BY: THAMIZHARASAN G/MANISH A SCALE:AS NOTED I REV:B DATE:03/26/2025 I E-02 REVISION DATE DESCRIPTION REV 02/29/2024 PERMIT PLAN A 03/26/2025 INVERTER UPDATE d PROJECT INFORMATION NAME:CURRY HONDA YORKTOWN (COM -41603) ADDRESS:3845 CROMPOND ROAD, YORKTOWN, NY 10598 41.291126,-73.851721 APN: 35.08-1-01 AHJ: NY -TOWN OF YORKTOWN UTILITY:CON EDISON PRN NUMBER: FMS -CU -2022-877 :('ILLUMINE ELECTRICAL MOUNTING DETAILS DRAFTED BY/QC'ED BY: THAMIZHARASAN G/MANISH A SCALE:AS NOTED I REV:B DATE:03/26/2025 I E-02 EQUIPMENT ELEVATION DETAILS: nr !'nnl nl ITT rnnnA n\/ Ann AV N'./� . , (EXTERIOR WALL OF THE BUILDING) Y'AIF:Ni5 DING) FROM AC ACCUMUU (FXTFR WARNING: IT IS A VIOLATION OF THE NYS EDUCATION LAW ARTICLE 145 FOR ANY PERSON, UNLESS HE IS ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS ITEM IN ANY WAY. I..V /KIN C r-1 IA! M MnA1TT THE BUILDING) IN IJVII 1\V IV IV I"If IIV IJ IJif IIJV IMV 1/ Iv I Kesowrion INUmDer �+L ,-_L�L_ Date I a 129 2—S FREEDOM" SOLAR POWER 4801 FRIEDRICH LN.SUITE 100 AUSTIN, TX 78744 P:512.640.3864 freedo m so larpower. com SYSTEM INFORMATION DC SYSTEM SIZE: 253.17kW AC SYSTEM SIZE: 200.00kW MODULES: (522)HANWHA QCELLS Q.PEA DUO XL-G10.3/BFG 485W INVERTERS: (4)SOLAREDGE TECHNOLOGIES SE50KUS (120/208V,3PH) OPTIMIZER: (264)SOLAREDGE P1101 POWER OPTIMIZER WIND SPEED:114MPH SNOW LOAD:30PSF MINIMUM TEMPERATURE: -15.80C MAXIMUM TEMPERATURE: 32.300 REVISION DATE DESCRIPTION REV 02/29/2024 PERMIT PLAN A B PROJECT INFORMATION NAME:CURRY HONDA YORKTOWN (COM -41603) ADDRESS:3845 CROMPOND ROAD, YORKTOWN, NY 10598 41.291126,-73.851721 APN: 35.08-1-01 AHJ:NY-TOWN OF YORKTOWN UTILITY:CON EDISON PRN NUMBER: FMS -CU -2022-877 :( ILLUMINE i EQUIPMENT ELEVATION DETAILS IDRAFTED BY/QC'ED BY: I THAMIZHARASAN G/MANISH A SCALE:AS NOTED I REV:B DATE:03/26/2025 I E-03 0--% M O VD rqco d' am I Ln O} Uz Lu Zoe O �YIn oG Oor,) 00 O QN EL OYC Oo �� O Qac LA ZO i O� 2Ln It �00 GC V REVISION DATE DESCRIPTION REV 02/29/2024 PERMIT PLAN A B PROJECT INFORMATION NAME:CURRY HONDA YORKTOWN (COM -41603) ADDRESS:3845 CROMPOND ROAD, YORKTOWN, NY 10598 41.291126,-73.851721 APN: 35.08-1-01 AHJ:NY-TOWN OF YORKTOWN UTILITY:CON EDISON PRN NUMBER: FMS -CU -2022-877 :( ILLUMINE i EQUIPMENT ELEVATION DETAILS IDRAFTED BY/QC'ED BY: I THAMIZHARASAN G/MANISH A SCALE:AS NOTED I REV:B DATE:03/26/2025 I E-03 ELECTRICAL DIAGRAM AND CALCULATION: DC SYSTEM SIZE: 253.17kW, AC SYSTEM SIZE: 200.00kW NOTE: 1.TYPICALLY EACH SOLAREDGE P1101 POWER OPTIMIZER IS CONNECTED TO TWO MODULES. 2.EACH SOLAREDGE P1101 POWER OPTIMIZER IS RAPID SHUTDOWN COMPLIANCE. 3.ALL DC FUSES SHOWN ARE CONNECTED EXTERNALLY TO THE INVERTER. 4.ALL CONDUIT SIZES SHOWN ARE THE MINIMUM REQUIRED TO MAINTAIN CORRECT CONDUIT FILL. LARGER CONDUIT IS ACCEPTABLE WHEN INSTALLED PER CODE AND GOVERNING GUIDELINES, 5.MONITORING DEVICE TO BE INSTALLED AT A LOCATION OF THE INSTALLER'S DISCRETION. 63HE DESIGNED INTERCONNECTION MEETS CODE REQUIREMENTS UNDER ENGINEERING SUPERVISION PER 2017 NEW YORK STATE ELECTRICAL CODE 705.12(B)(2)(3)(e). HANWHA QCELLS Q.PEAK DUO XL-G10.3/BFG 485W(131 MODULES) UNIT 01-INPIJT 01: 22 MODULES (11, P1101 OPTIMIZER) UNIT 01 -INPUT 02: 22 MODULES (11, P1101 OPTIMIZER) UNIT 02 -INPUT 01: 21 MODULES (11, P1101 OPTIMIZER) UNIT 02 -INPUT 02: 22 MODULES (11, P1101 OPTIMIZER) UNIT 03 -INPUT 01: 22 MODULES (11, P1101 OPTIMIZER) UNIT 03 -INPUT 02: 22 MODULES (11, P1101 OPTIMIZER) OPTIMIZER OUTPUT= 18A AT STC : Pmax = 485W, Voc = 53.63V, Isc = 11.16A HANWHA QCELLS Q.PEAK DUO XL-G10.3/BFG 485W (130 MODULES) UNIT 01 -INPUT 01: 22 MODULES (11, P1101 OPTIMIZER) UNIT 01 -INPUT 02: 22 MODULES (11, P1101 OPTIMIZER) UNIT 02 -INPUT 01: 22 MODULES (11, P1101 OPTIMIZER) UNIT 02 -INPUT 02: 21 MODULES (11, P1101 OPTIMIZER) UNIT 03 -INPUT 01: 21 MODULES (11, P1101 OPTIMIZER) UNIT 03 -INPUT 02: 22 MODULES (11, P1101 OPTIMIZER) (N) DC (N) SOLAREDGE TECHNOLOGIES SE50KUS (120/208V, 3PH), 5000OW INVERTER -01 (EXTERIOR WALL OF THE BUILDING) SWITCH LOAD RATED DC DISCONNECT & AFCI ( RAPID SHUTDOWN COMPLIANCE) (N) SOLAREDGE TECHNOLOGIES SESOKUS (120/208V, 3PH), 5000OW INVERTER -02 (EXTERIOR WALL OF THE BUILDING) Box SWITCH (N)E-GAUGE MONITOR �� )) (EXTERIOR WALL OF THE BUILDING) 3P/20A CELL MODEM r77 r (N)800A AC ACCUMULATION PANEL, 3P 3PH 4W, NEMA 3R 120/208V(EXTERIOR WALL OF THE BUILDING) WARNING: IT IS A VIOLATION OF THE NYS EDUCATION LAW ARTICLE 145 FOR ANY PERSON, UNLESS HE IS ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL FNGINEER, TO ALTER THIS ITEM IN ANY WAY. EXISTING 120/208V 3PH 4W 800A (4) 6 AWG THHN/THWN-2 IN (INSIDE THE ELECTRICAL ROOM) 1" EMT METER:78 530 057 (E) UTILITY CON EDISON TRANSFORMER (E) CT CABINET E (3)CT'S IN 3/4" EMT ' (1 PER PHASE) UTILITY _ GRID UTILITY TRANSFORMER UTILITY SIDE PRIMARY 120/208V, NEMA 3R (POLE MOUNTED) (3)CT'S IN 3/4" EMT A--(1 PER PHASE) (E) 800A MAINI SERVICE DISCONN DISTRIBUTION PANEL OPTIMIZER OUTPUT= UNIT 01 -INPUT 01: 22 MODULES (11, P1101 OPTIMIZER) 175A w_ UNIT 02 -INPUT 01: 22 MODULES (11, P1101 OPTIMIZER) AT STC :Pmax = 485W, Voc = 53.63V, Isc = 11.16A 6 21 MODULES (11, P1101 OPTIMIZER) 25AFUSES N G 521T-1 r\ 89L GENERATOR 22 MODULES (11, P1101 OPTIMIZER) LOAD SIDE TAP CONDUCTOR NEUTRAL GROUND LOAD RATED DC DISCONNECT 8t, �DISCONNECTON 1-1/2" EMT (12) 10 AWG PV WIRE 2kV THE LINE (1) 6 AWG THHN/THWN-2 2 1 ( RAPID SHUTDOWN COMPLIANCE) 175A MANUAL LOCKABLE (1) 6 AWG THHN/THWN-2 SIDE LUGS OF 2 3" EMT (3) 500 KCMILTHHN/THWN-2 52� WITH VISIBLE BREAK 4 THE MDP 3" EMT (3) 500 KCMILTHHN/THWN-2 (N) SOLAREDGE TECHNOLOGIES SE50KUS (120/208V, 3PH), 5000OW INVERTER -03 �� (N) SOOA AC DISCONNECT z n ao HANWHA QCELLS Q.PEAK DUO XL G10.3/BFG 485W (131 MODULES)(EXTERIOR WALL OF THE BUILDING) 175A 3 4 E UNIT 01 -INPUT 01: 22 MODULES11 P1101 OPTIMIZER MODULES(11, ) CL INTERNAL DC SAFETY 52IT-3 %�X (n ce,1 UNIT 01 -INPUT 02: 22 MODULES (11, P1101 OPTIMIZER) 1 1 Fuse sox swlrcH Z �� • W p UNIT 02 -INPUT 01: 22 MODULES (11, P1101 OPTIMIZER) Z - - - 00. RT Z0 UNIT 02 -INPUT 02: 21 MODULES (11, P1101 OPTIMIZER) O 175A 700A FUSE U UNIT 03 -INPUT 01: 22 MODULES (11, P1101 OPTIMIZER) -- 52IT-4 I UNIT 03 -INPUT 02: 22 MODULES (11, P1101 OPTIMIZER) -- G zsAFuses �� 175 AMP BREAKER (INV 01) 800A FUSED AC 800A BUS RATING, OPTIMIZER OUTPUT=I8A N 175 AMP BREAKER (INV 02) DISCONNECT SWITCH, 120/208V, 3PH, 4W AT STC :Pmax = 485W, Voc = 53.63V, Isc = 11.16A LOAD RATED DC DISCONNECT & AFCI 175 AMP BREAKER (INV 03) 3P 3PH 4W, NEMA 3R, 600VAC (INSIDE THE ELECTRICAL ( RAPID SHUTDOWN COMPLIANCE) 175 AMP BREAKER (INV 04) (EXTERIOR WALL OF THE ROOM) BUILDING) HANWHA QCELLS Q.PEAK DUO XL-G10.3/BFG 485W (130 MODULES) UNIT 01 -INPUT 01: 22 MODULES (11, P1101 OPTIMIZER) UNIT 01 -INPUT 02: 22 MODULES (11, P1101 OPTIMIZER) UNIT 02 -INPUT 01: 22 MODULES (11, P1101 OPTIMIZER) UNIT 02 -INPUT 02: 21 MODULES (11, P1101 OPTIMIZER) UNIT 03 -INPUT 01: 21 MODULES (11, P1101 OPTIMIZER) UNIT 03 -INPUT 02: 22 MODULES (11, P1101 OPTIMIZER) OPTIMIZER OUTPUT= 18A AT STC : Pmax = 485W, Voc = 53.63V, Isc = 11.16A (EXTERIOR WALL OF THE BUILDING) (N) SOLAREDGE TECHNOLOGIES SE50KUS (120/208V, 3PH), 5000OW INVERTER -04 (EXTERIOR WALL OF THE BUILDING) INTERNAL FUSE BOX 25A FUSE DC SAFETY SWITCHVIG REVISION CONDUIT SCHEDULE 0 03/26/2025 INVERTER UPDATE B tD LOAD RATED DC DISCONNECT & AFCI ( RAPID SHUTDOWN COMPLIANCE) GROUND 800A BUS RATING, ELECTRODE 120/208V, 3PH, 4W (INSIDE THE ELECTRICAL ROOM) sealed 03apr2025 mike@h2dc.com H2DC PLLC NY COAk PB -082933 ELECTRICAL ONLY PRE CONSTRUCTION DRAWING SET FREEDOM" SOLAR POWER 4801 FRIEDRICH W.SUITE 100 AUSTIN, Tx 78744 P:512.640.3864 freedomsolarpow er. com SYSTEM INFORMATION DC SYSTEM SIZE: 253.17kW AC SYSTEM SIZE: 200.00kW MODULES: (522)HANWHA QCELLS Q.PEAK DUO XL-G10.3/BFG 485W INVERTERS: (4)SOLAREDGE TECHNOLOGIES SE50KUS (120/208V, 3PH) OPTIMIZER: (264)SOLAREDGE P1101 POWER OPTIMIZER WIND SPEED:114MPH SNOW LOAD:30PSF MINIMUM TEMPERATURE: -15.80C MAXIMUM TEMPERATURE: 32.3°C M REVISION CONDUIT SCHEDULE 0 03/26/2025 INVERTER UPDATE B tD �00 TAG ID PR FEEDER LLEL FE CONDUIT SIZE CONDUCTOR NEUTRAL GROUND 1 1 1-1/2" EMT (12) 10 AWG PV WIRE 2kV NONE (1) 6 AWG THHN/THWN-2 2 1 1-1/2" EMT (3) 2/0 AWG THHN/THWN-2 NONE (1) 6 AWG THHN/THWN-2 3 2 3" EMT (3) 500 KCMILTHHN/THWN-2 (1) 500 KCMILTHHN/THWN-2 (1) 1/0 AWG THHN/THWN-2 4 2 3" EMT (3) 500 KCMILTHHN/THWN-2 (1) 500 KCMILTHHN/THWN-2 NONE GROUND 800A BUS RATING, ELECTRODE 120/208V, 3PH, 4W (INSIDE THE ELECTRICAL ROOM) sealed 03apr2025 mike@h2dc.com H2DC PLLC NY COAk PB -082933 ELECTRICAL ONLY PRE CONSTRUCTION DRAWING SET FREEDOM" SOLAR POWER 4801 FRIEDRICH W.SUITE 100 AUSTIN, Tx 78744 P:512.640.3864 freedomsolarpow er. com SYSTEM INFORMATION DC SYSTEM SIZE: 253.17kW AC SYSTEM SIZE: 200.00kW MODULES: (522)HANWHA QCELLS Q.PEAK DUO XL-G10.3/BFG 485W INVERTERS: (4)SOLAREDGE TECHNOLOGIES SE50KUS (120/208V, 3PH) OPTIMIZER: (264)SOLAREDGE P1101 POWER OPTIMIZER WIND SPEED:114MPH SNOW LOAD:30PSF MINIMUM TEMPERATURE: -15.80C MAXIMUM TEMPERATURE: 32.3°C / APPROVED SEPARATE GEC:#3/0 AWG CU -BOND TO- Resolution Number 25--3_ Date I- 1 � 1 z o yS EXISTING BUILDING GROUNDING SYSTEM FXISTING B1,111 DING GROUNDING SYSTEM NOTES APPENDIX (AS APPLICABLE FOR TO BE BUILT DRAWING SETS): (A) TOTAL AC VOLTAGE DROP NOT TO EXCEED 2°o TO INTERCONNECTION, < 3% FROM INVERTER(S) TO UTILITY TRANSFORMER. (B) ALL CONNECTORS 75C RATED. (C) ALL CONDUCTORS COPPER, UNLESS OTHERWISE NOTED. DUE TO HIGHER COEFFICIENT OF EXPANSION, ALUMINUM CONDUCTORS REQUIRE MORE MAI NTENANCE/INSPECT►ON THAN COPPER CONDUCTORS. ANNUAL RETORQUEING AS WELL AS INFRARED INSPECTION, MINIMALLY. BE CAREFUL NOT TO CONNECT ALUMINUM WITH COPPER RATED CONDUCTORS OR FITTINGS DURING CONSTRUCTION, TERMINALS SHOULD BE DUAL RATED. MATERIAL FOR NEUTRAL AND EGC SHOULD BE THE SAME IN A GIVEN SEGMENT. (D) OUTDOOR EQUIPMENT NEMA3R. (E) ALL CONDUCTORS FOR PV & ESS SYSTEMS MUST BE PROTECTED FROM ACCESS BY A FENCE OR SUITABLE COVER, OR OUT OF REACH. (F) PROPERTY LINES, BOUNDARIES AND ALL OTHER EXTERIOR MEASUREMENTS ARE FOR REFERENCE ONLY, AND MUST BE VERIFIED BY A LICENSED SURVEYOR OR CIVIL ENGINEER. (G) ENERGY STORAGE SYSTEMS ARE REQUIRED TO BE INSTALLED IN LOCATIONS AND CONTAINERS IN COMPLIANCE WITH THEIR LISTING REQUIREMENTS. (H) IF TRAVEL ACROSS A ROOF IS LIMITED TO FIRE SETBACK AREAS, FALL RESTRAINT SYSTEMS MAY BE REQUIRED. (1) NO PVC ALLOWED ON ROOF OR IN ATTIC. (J) MC4 CONNECTORS MAY NOT BE JOINED WITH 'MC4 COMPATIBLE' CONNECTORS. (K) FOR COMMERCIAL SYSTEMS - UNDER MODULE WIRE SYSTEMS ARE REQUIRED, RACEWAY FILL MUST NOT EXCEED 40°o REFER TO LOCAL REGULATIONS FOR EXCEPTIONS. (L) TAP CONNECTION IN PANEL MUST NOT VIOLATE CONDITIONS OF ACCEPTABILITY FROM PANEL MANUFACTURER'S NRTL LISTING, OR FIELD LABEL REQUIRED. (M) PV WIRES MAY NOT BE LAID DIRECTLY ON ROOF, WIRE MANAGEMENT SUCH AS SNAKE TRAY, ETC. MUST BE USED 40°o FILL MAX. (N) TY WRAPS FOR WIRE MANAGEMENT MUST BE STRUCTURAL (S21) UL APPROVED, OR SUN BUNDLER OR EQUAL. (0) DRAWINGS ARE DIAGRAMMATIC AND INDICATE GENERAL ARRANGEMENT OF SYSTEMS AND WORK. CONDUIT ROUTING, WHEN INDICATED, IS SHOWN DIAGRAMMATICALLY AND DOES NOT SHOW ALL OFFSETS, DROPS, AND RISES OF RUNS. THE CONTRACTOR SHALL ALLOW IN HIS PRICE FOR ROUTING OF CONDUIT TO AVOID OBSTRUCTIONS. (P) BURIED CONDUITS UNDER AREAS SUBJECT TO VEHICLE TRAFFIC REQUIRE MIN 24" COVER. (Q) SOLAREDGE INVERTERS MAY BE EQUIPPED WITH OCPD ON DC LINES, IF NOT EXTERNAL OCPD MAY BE REQUIRED FOR STRINGS NUMBERING 3 OR MORE. (R) BATTERIES MUST BE IN AN APPROVED BATTERY ENCLOSURE (SPECIFIED BY THE BATTERY MANUFACTURER), SUITABLE FOR THE LOCATION. (S) NM -B OR PAPER INSULATED CONDUCTORS MAY NOT BE USED EXTERIOR. INSTEAD USE THWN-2 OR EQUAL IN EMT CONDUIT. (T) FOR MULTIPLE BATTERIES/INVERTERS SHARING A COMMON DC BUS, OCPD PROTECTION IS REQUIRED ON BOTH SIDES OF THE BUS AND AT INVERTERS DUE TO 2 WAY CURRENTS. (U) THE DEVELOPER IS REQUIRED TO CONFIRM EXISTING ELECTRICAL SERVICE SIZE FROM THE UTILITY, AND MAY NOT RELY SOLELY ON EXISTING BREAKER SIZES. (V) CONNECTING TO UTILITY EQUIPMENT REQUIRES PRIOR UTILITY CONSENT. (W) ALL CONNECTIONS MADE FOR FLOATING SOLAR INSTALLATIONS, ABOVE A BODY OF WATER, MUST BE SUBMERSIBLE COMPLIANT. (X) WHEN BUILDING PV SYSTEMS WITH POWER LINE COMMUNICATIONS FOR RSD SOLUTIONS, FOLLOWING MANUFACTURERS IvNSTRUCTIONS ON CONDUCTOR AND CONDUIT SPACING IS PARAMOUNT, OR HAZARD MAY RESULT. (Y) NOTIFY ELECTRICAL ENGINEER WHO'S SEAL IS ON THIS DRAWING PRIOR TO ANY AND ALL CHANGES IN DESIGN. (Z) PROJECT RELATED SIGNAL/COMMUNICATION CONDUCTORS MAY ONLY BE RUN IN THE SAME CONDUIT WITH POWER CONDUCTORS IF THEIR RATING FOR THE OUTER MOST JACKET IS EQUAL TO OR GREATER THAN THE INSULATION REQUIRED FOR THE HIGHEST VOLTAGE POWER CONDUCTOR CIRCUIT THAT THEY ARE SHARING THE RESPECTIVE CONDUIT WITH. M REVISION DATE DESCRIPTION REV 0 03/26/2025 INVERTER UPDATE B tD �00 �a% PROJECT INFORMATION NAME:CURRY HONDA YORKTOWN (COM -41603) 1 LO UTILrrY:CON EDISON PRN NUMBER:FMS-CU-2022-877 O THREE LINE DIAGRAM O} SCALE:ASNOTED REV:B U Z z 4 n Z O N O 3:YL OOM ao >0 CL O ce,1 rV Z O 00. RT Z0 O U _ In I 00M U / APPROVED SEPARATE GEC:#3/0 AWG CU -BOND TO- Resolution Number 25--3_ Date I- 1 � 1 z o yS EXISTING BUILDING GROUNDING SYSTEM FXISTING B1,111 DING GROUNDING SYSTEM NOTES APPENDIX (AS APPLICABLE FOR TO BE BUILT DRAWING SETS): (A) TOTAL AC VOLTAGE DROP NOT TO EXCEED 2°o TO INTERCONNECTION, < 3% FROM INVERTER(S) TO UTILITY TRANSFORMER. (B) ALL CONNECTORS 75C RATED. (C) ALL CONDUCTORS COPPER, UNLESS OTHERWISE NOTED. DUE TO HIGHER COEFFICIENT OF EXPANSION, ALUMINUM CONDUCTORS REQUIRE MORE MAI NTENANCE/INSPECT►ON THAN COPPER CONDUCTORS. ANNUAL RETORQUEING AS WELL AS INFRARED INSPECTION, MINIMALLY. BE CAREFUL NOT TO CONNECT ALUMINUM WITH COPPER RATED CONDUCTORS OR FITTINGS DURING CONSTRUCTION, TERMINALS SHOULD BE DUAL RATED. MATERIAL FOR NEUTRAL AND EGC SHOULD BE THE SAME IN A GIVEN SEGMENT. (D) OUTDOOR EQUIPMENT NEMA3R. (E) ALL CONDUCTORS FOR PV & ESS SYSTEMS MUST BE PROTECTED FROM ACCESS BY A FENCE OR SUITABLE COVER, OR OUT OF REACH. (F) PROPERTY LINES, BOUNDARIES AND ALL OTHER EXTERIOR MEASUREMENTS ARE FOR REFERENCE ONLY, AND MUST BE VERIFIED BY A LICENSED SURVEYOR OR CIVIL ENGINEER. (G) ENERGY STORAGE SYSTEMS ARE REQUIRED TO BE INSTALLED IN LOCATIONS AND CONTAINERS IN COMPLIANCE WITH THEIR LISTING REQUIREMENTS. (H) IF TRAVEL ACROSS A ROOF IS LIMITED TO FIRE SETBACK AREAS, FALL RESTRAINT SYSTEMS MAY BE REQUIRED. (1) NO PVC ALLOWED ON ROOF OR IN ATTIC. (J) MC4 CONNECTORS MAY NOT BE JOINED WITH 'MC4 COMPATIBLE' CONNECTORS. (K) FOR COMMERCIAL SYSTEMS - UNDER MODULE WIRE SYSTEMS ARE REQUIRED, RACEWAY FILL MUST NOT EXCEED 40°o REFER TO LOCAL REGULATIONS FOR EXCEPTIONS. (L) TAP CONNECTION IN PANEL MUST NOT VIOLATE CONDITIONS OF ACCEPTABILITY FROM PANEL MANUFACTURER'S NRTL LISTING, OR FIELD LABEL REQUIRED. (M) PV WIRES MAY NOT BE LAID DIRECTLY ON ROOF, WIRE MANAGEMENT SUCH AS SNAKE TRAY, ETC. MUST BE USED 40°o FILL MAX. (N) TY WRAPS FOR WIRE MANAGEMENT MUST BE STRUCTURAL (S21) UL APPROVED, OR SUN BUNDLER OR EQUAL. (0) DRAWINGS ARE DIAGRAMMATIC AND INDICATE GENERAL ARRANGEMENT OF SYSTEMS AND WORK. CONDUIT ROUTING, WHEN INDICATED, IS SHOWN DIAGRAMMATICALLY AND DOES NOT SHOW ALL OFFSETS, DROPS, AND RISES OF RUNS. THE CONTRACTOR SHALL ALLOW IN HIS PRICE FOR ROUTING OF CONDUIT TO AVOID OBSTRUCTIONS. (P) BURIED CONDUITS UNDER AREAS SUBJECT TO VEHICLE TRAFFIC REQUIRE MIN 24" COVER. (Q) SOLAREDGE INVERTERS MAY BE EQUIPPED WITH OCPD ON DC LINES, IF NOT EXTERNAL OCPD MAY BE REQUIRED FOR STRINGS NUMBERING 3 OR MORE. (R) BATTERIES MUST BE IN AN APPROVED BATTERY ENCLOSURE (SPECIFIED BY THE BATTERY MANUFACTURER), SUITABLE FOR THE LOCATION. (S) NM -B OR PAPER INSULATED CONDUCTORS MAY NOT BE USED EXTERIOR. INSTEAD USE THWN-2 OR EQUAL IN EMT CONDUIT. (T) FOR MULTIPLE BATTERIES/INVERTERS SHARING A COMMON DC BUS, OCPD PROTECTION IS REQUIRED ON BOTH SIDES OF THE BUS AND AT INVERTERS DUE TO 2 WAY CURRENTS. (U) THE DEVELOPER IS REQUIRED TO CONFIRM EXISTING ELECTRICAL SERVICE SIZE FROM THE UTILITY, AND MAY NOT RELY SOLELY ON EXISTING BREAKER SIZES. (V) CONNECTING TO UTILITY EQUIPMENT REQUIRES PRIOR UTILITY CONSENT. (W) ALL CONNECTIONS MADE FOR FLOATING SOLAR INSTALLATIONS, ABOVE A BODY OF WATER, MUST BE SUBMERSIBLE COMPLIANT. (X) WHEN BUILDING PV SYSTEMS WITH POWER LINE COMMUNICATIONS FOR RSD SOLUTIONS, FOLLOWING MANUFACTURERS IvNSTRUCTIONS ON CONDUCTOR AND CONDUIT SPACING IS PARAMOUNT, OR HAZARD MAY RESULT. (Y) NOTIFY ELECTRICAL ENGINEER WHO'S SEAL IS ON THIS DRAWING PRIOR TO ANY AND ALL CHANGES IN DESIGN. (Z) PROJECT RELATED SIGNAL/COMMUNICATION CONDUCTORS MAY ONLY BE RUN IN THE SAME CONDUIT WITH POWER CONDUCTORS IF THEIR RATING FOR THE OUTER MOST JACKET IS EQUAL TO OR GREATER THAN THE INSULATION REQUIRED FOR THE HIGHEST VOLTAGE POWER CONDUCTOR CIRCUIT THAT THEY ARE SHARING THE RESPECTIVE CONDUIT WITH. REVISION DATE DESCRIPTION REV 02/29/2024 PERMIT PLAN A 03/26/2025 INVERTER UPDATE B PROJECT INFORMATION NAME:CURRY HONDA YORKTOWN (COM -41603) ADDRESSMANAGEMENT YORKTOWN,N 10598CROMND ROAD, YORKTOWN, NY 10598 APN:35z8-1-01s17z1 APN: 35.08-1-01 AHJ:NY-TOWN OFYORKTOWN UTILrrY:CON EDISON PRN NUMBER:FMS-CU-2022-877 :(' 1 LLU M I N E i THREE LINE DIAGRAM DRAFTED BY/QC'EDBY: THAMIZHARASAN G/MANISH A SCALE:ASNOTED REV:B DATE:03/26/2025 E-04 ELECTRICAL DIAGRAM AND CALCULATION: DC SYSTEM SIZE: 253.17kW, AC SYSTEM SIZE: 200.00kW OCPD CALCULATIONS MAIN DISTRIBUTION PANEL RATING:800A OCPD CALCULATIONS: INVERTER OVERCURRENT PROTECTION= INVERTER O/P I X CONTINUOUS LOAD(1.25) =((139.5AX4))x1.25=697.50A=>PV BREAKFR/FUSE = 700A ALLOWABLE BACKFEED IS 800A>- IOOA BREAKER/FUSE THE DESIGNED INTERCONNECTION MEETS THE 705.12(B)(2)(3)(e) REQUIREMENTS. ELECTRICAL CALCULATIONS: SYSTEM INFO: 253.17 kW DC SYSTEM SIZE (522)HANWHA QCELLS Q.PEAK DUO XL-G10.3/BFG 485W MODULES (4)SOLAREDGE TECHNOLOGIES SE50KUS (120/208V, 3PH) (264)SOLAREDGE P1101 POWER OPTIMIZER SYSTEM CHARACTERISTICS INV 01 & 03: VMP - INVERTER FIXED STRING VOLTAGE =370V VOC - MAX INVERTER SYSTEM VOLTAGE =600V OPERATING CURRENT = DC SYSTEM SIZE/VMP= 171.72A SHORT CIRCUIT CURRENT = MAXIMUM INPUT CURRENT=139.5A SYSTEM CHARACTERISTICS INV 02 & 04: VMP INVERTER FIXED STRING VOLTAGE =370V VOC MAX INVERTER SYSTEM VOLTAGE =600V OPERATING CURRENT = DC SYSTEM SIZE/VMP= 170.41A SHORT CIRCUIT CURRENT= MAXIMUM INPUT CURRENT=139.5A DC WIRE SIZING (TAG 01): MAX CIRCUIT CURRENT = (OPTIMIZER OUTPUT) X (HIGH IRRADIANCE)[690.8(A)(1)] X (CONTINUOUS LOAD)[690.531 = 18A X 1.25 X 1= 22.50A ADJUSTED CONDUCTOR AMPACITY = (HIGH TEMP) [PER TABLE 310.15(B)(2)(a)] X (CONDUIT FILL) [PER TABLE 310.15(B)(3)(a)] X (CONDUCTOR AMPACITY) [PER TABLE 310.15(B)(16)] = 0.96X 0.5 X 40A=19.20A TERMINAL RATING, [PER NEC 110.14(C)] - 10 AWG, 60°C RATED = 30A 30A > 22.50A, SO THE TERMINAL RATING GOVERNS THE CONDUCTOR SIZING ALSO,19.20A > 18A, AND 10 AWG IS SUFFICIENT. AC WIRE SIZING (TAG 02): MAX AC OUTPUT CURRENT = (MAX INVERTER OUTPUT) X (CONTINUOUS LOAD) [PER NEC 690.52] =139.5A X 1.25 = 174.38A ADJUSTED CONDUCTOR AMPACITY = (HIGH TEMP) [PER TABLE 310.15(B)(2)(a)] X (CONDUIT FILL) [PER TABLE 310.15(B)(3)(a)] X (CONDUCTOR AMPACITY) [PER TABLE 310.15(B)(16)] = 0.96 X 1 X 195A = 187.20A TERMINAL RATING, [PER NEC I.10.14(C)] - 2/0 AWG , 75°C RATED = 175A 175A>_174.38A, SO THE ADJUSIL-D CONDUCTOR AMPACITY GOVERNS THE CONDUCTOR SIZING ALSO,187.20A >139.5A, AND 2/0 AWG IS SUFFICIENT INVERTER OVER CURRENT PROTECTION (INVERTER MAX CURRENT) X (CONTINUOUS LOAD)=139.5A X 1.25 = 174.38A -->175A OVERCURRENT PROTECTION AC ACCUMULATION PANEL TO POINT INTERCONNECTION (TAG 03): MAX AC OUTPUT CURRENT = (MAX INVERTER OUTPUT) X (CONTINUOUS LOAD) [PER NEC 690.52] = (139.5Ax4X1.25) = 697.50A/2=348.75A ADJUSTED CONDUCTOR AMPACITY = (HIGH TEMP) [PER TABLE 310.15(B)(2)(a)] X (CONDUIT FILL) [PER TABLE 310.15(6)(3)(a)] X (CONDUCT OR AMPACITY) [PER TABLE 310.15(B)(16)] = 0.96 X 1 X 430A = 412.80A TERMINAL RATING, [PER NEC 110.14(C)] - 500 KCMIL, 75°C RATED = 380A 380A >348.75A, SO THE ADJUSTED CONDUCTOR AMPACITY GOVERNS THE CONDUCTOR SIZING ALSO,412.80A >279A, AND 500 KCMIL IS SUFFICIENT INVERTER OVER CURRENT PROTECTION (INVERTER MAX CURRENT) X (CONTINUOUS LOAD)=139.5A X4X 1.25 = 697.50A -->700A OVERCURRENT PROTECTION NOTE: 1.THIS INSTALLATION IS TO BE CONSIDERED SUPERVISED.ALL NEW ADDITIONS AND ALTERATIONS TO ANY EQUIPMENT IDENTIFIED IN THIS DOCUMENT MUST BE MADE WITH ENGINEERING SUPERVISION AND ALL WORK MUST BE COMPLETED BY QUALIFIED PERSONNEL. 2.ALL EQUIPMENT AND TERMINALS MUST BE MINIMUM 75°C RATED. 3.ALL CONDUCTORS ARE COPPER, UNLESS OTHERWISE SPECIFIED. 4.TAP DISCONNECTS ARE WITHIN THE 10 FOOT PER TAP RULE. 5.TAPS ARE MADE USING LISTED DEVICES. OPTIMIZER CHARACTERISTICS MODEL SOLAREDGEP1101 POWER OPTIMIZER MAX INPUT VOLTAGE 125 VDC MAX INPUT CURRENT 14.1 ADC MAX OUTPUT CURRENT 18 ADC MODULE SPECIFICATION SOURCE INVERTER -01 SPECIFICATIONS TAG MODEL HANWHA QCELLS Q.PEAK DUO XL-G10.3/BFG 485W MODEL SOLAREDGE TECHNOLOGIES SE50KUS (120/208V, 3PH) POWER RATING 50000W MODULE POWER @STC 485W MAX OUTPUT CURRENT 139.5A OPEN CIRCUIT VOLTAGE:VoC 53.63V CEC WEIGHTED EFFICIENCY 97% MAX POWER VOLTAGE:Vmp 45.63V MAX INPUT CURRENT 139.5A SHORT CIRCUIT CURRENT:IsC 11.16A MAX POWER CURRENT:Imp 10.63A MAX DC VOLTAGE 600V WARNING: IT IS A VIOLATION OF THE NYS EDUCATION LAW ARTICLE 145 FOR ANY PERSON, UNLESS HE IS ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS ITEM IN ANY WAY. DC VOLTAGE DROP CALCULATION SOURCE TERMINATION TAG CONDUIT TYPE CURRENT (IMP) STRING VOLTAGE AT 2%DB (VMP) #SET OF PARALLEL CONDUCTOR CONDUCTOR CONDUCTOR MATERIAL RESISTANCE AT 75 DEG C RESISTANCE AT 2%DB MAX CONDUTOR LENGTH(ft) %V. DROP MODULES INVERTER Ol 1 EMT 18 1 370 1 1 1 C AWG 10 Cu 0.00124000 0.001068978 250 2.600/c MODULES INVERTER 02 1 EMT 18 370 1 C AWG 10 Cu 0.00124000 0.001068978 130 1.35% MODULES INVERTER 03 1 EMT 18 370 1 C AWG 10 Cu0.00124000 10.001068978 215 2.24% MODULES INVERTER 04 1 EMT 18 370 1 C AWG 10 Cu 0.00124000 10.001068978 150 1.56% Max Vdrop 2.60% AVERAGE Vdrop 1.94% 3 PHASE AC VOLTAGE DROP CALCULATION SOURCE TERMINATION TAG CONDUIT TYPE CURRENT VOLTAGE #SET OF PARALLEL CONDUCTOR CONDUCTOR CONDUCTOR MATERIAL RESISTANCE AT 75 DEG C RESISTANCE AT 2%DB MAX CONDUTOR LENGTH(ft) %V. DROP INVERTER 01 AC ACCUMULATION PANEL 2 EMT 139.5 208 1 K AWG 2/0 Cu 0.00010000 8.62079E-05 10 0.10% INVERTER 02 AC ACCUMULATION PANEL 2 EMT 139.5 208 1 K AWG 2/0 Cu 0.00010000 8.62079E-05 10 0.10% INVERTER 03 AC ACCUMULATION PANEL 2 EMT 139.5208 1 K AWG 2/0 CU 0.00010000 8.62079E-05 10 0.10% INVERTER 04 AC ACCUMULATION PANEL 2 EMT 139.5 208 1 1 K AWG 2/0 CU 0.00010000 8.62079E-05 10 0.10% COLLECTION TO POI AC ACCUMULATION PANEL AC DISCONNECT 3 EMT 558 208 2 R 500 KCMIL Cu 0.00003200 0.000027587 125 0.80% AC DISCONNECT POI 4 EMT 558 208 2 R 500 KCMIL CU 0.00003200 0.000027587 10 0.06% Max Vdrop 0.97% AVERAGE Vdrop 0.97% TOTAL MAX SYSTEM VDROP 3.57% 7t �v Il { ib'T iV sealed 03apr2025 mike@h2dc.com H2DC PLLC NY CoA#: PB -082933 ELECTRICAL ONLY PRE CONSTRUCTION DRAWING SET A77^"' S7"-:) Resolution Number 2-5 - 1.3 Date 2 FREEDOM" SOLAR POWER 4801 FRIEDRICH LN.SUrrE 100 AUSTIN, TX 78744 P:512.640.3864 freedomsolarpower. tom SYSTEM INFORMATION DC SYSTEM SIZE: 253.17kW AC SYSTEM SIZE: 200.00kW MODULES: (522)HANWHA QCELLS Q.PEA DUO XL-G10.3/BFG 485W INVERTERS: (4)SOLAREDGE TECHNOLOGIES SE50KUS (120/208V, 3PH) OPTIMIZER: (264)SOLAREDGE P1101 POWER OPTIMIZER WIND SPEED:114MPH SNOW LOAD:30PSF MINIMUM TEMPERATURE: -15.8°C MAXIMUM TEMPERATURE: 32.3°C REVISION DATE DESCRIPTION REV 02/29/2024 PERMIT PLAN A 03/26/2025 1 INVERTER UPDATE B PROJECT INFORMATION NAME:CURRY HONDA YORKTOWN (COM -41603) ADDRESS:3845 CROMPOND ROAD, YORKTOWN, NY 10598 41.291126,-73.851721 APN: 35.08-1-01 AHJ:NY-TOWN OF YORKTOWN UTILITY:CON EDISON PRN NUMBER: FMS -CU -2022-81/ :ILLUMINE i ELECTRICAL CALCULATION DRAFTED BY/QC'ED BY: THAMIZHARASAN G/MANISH A SCALE:AS NOTED I REV:B DATE:03/26/2025 I E-05 M O 74 00 aI LO o O� U z U `.o z Z r1 O n O Y �, O 00 O a it rh >�Yo� a ac o 0 W Q r' z O i0 0. c Z0 O u �t 00 M N�N 1.I. 6f. U REVISION DATE DESCRIPTION REV 02/29/2024 PERMIT PLAN A 03/26/2025 1 INVERTER UPDATE B PROJECT INFORMATION NAME:CURRY HONDA YORKTOWN (COM -41603) ADDRESS:3845 CROMPOND ROAD, YORKTOWN, NY 10598 41.291126,-73.851721 APN: 35.08-1-01 AHJ:NY-TOWN OF YORKTOWN UTILITY:CON EDISON PRN NUMBER: FMS -CU -2022-81/ :ILLUMINE i ELECTRICAL CALCULATION DRAFTED BY/QC'ED BY: THAMIZHARASAN G/MANISH A SCALE:AS NOTED I REV:B DATE:03/26/2025 I E-05 1. 2M 3. 4 A WARNING ELECTRIC SHOCK HAZARD TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION PLACARDS JrAC VOLTAIC SYSTEM AC DISCONNECT SWITCH TED AC OPERATING CURRENT 558 AMPS OMINAL OPERATING VOLTAGE 208 VAC DC VOLTAGE IS ALWAYS PRESENT WHEN SOLAR MODULES ARE EXPOSED TO SUNLIGHT LABEL LOCATION 711111 AC DISCONNECT,POINT OF INTERCONNECTION [PER CODE: NEC 690.13(B)] LABEL LOCATION INVERTER, JUNCTION BOXES, AC DISCONNECI [PER CODE NEC 690.13] LABEL LOCATION CONDUIT, JUNCTION BOX [PER CODE: NEC 690.31(D)(2)] MAXIMUM DC VOLTAGE .11 LABEL LOCATION DC DISCONNECT[PER CODE: NEC690.53] RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM LABEL LOCATION INVERTER 01&02 [PER CODE: NEC 690.56(C)(2)] LABEL LOCATION AC DISCONNECT , POINT OF INTERCONNECTION [PER CODE: NEC 690.54] LABEL LOCATION AC DISCONNECT, POINT OF INTERCONNECTION [PER CODE: NEC 690.13(B)] WARNING DUAL POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC SYSTEM LABEL LOCATION POINT OF INTERCONNECTION [PER CODE: NEC 705.12(C)] 90 SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SOLAR rLrcrRic Pv PANELS 111/1 SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY LABEL LOCA I ION AC DISCONNECT, DC DISCONNECTROINT OF INTERCONNECTION [PER CODE: NEC 690.56(C)] FREEDOM'° SOLAR POWER AWARNING ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE & LOAD SIDES MAYBE ENERGIZED IN OPEN POSITION DO VOT DISCONNECT FUSES UNDER LOAD THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAYBE ENERGIZED PHOTOVOLTAIC SYSTEM OC DISCONNECT AUTHORIZED PERSONNEL ONLY Note. WARNING labels must resemb,e formal in example above with over -sized WARNING. exclamation point in triangle, colors, etc. WARNING: POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN (1. } U 1 ILITY TRANSFORMER (POLE MOUNTED) PHOTOVOLTAIC ARRAY ON ROOF (N) AC ACCUMULATION PANEL (EXTERIOR WALL OF THE BUILDING) (N) DC GUTTER BOX (EXTERIOR WALL OF THE BUILDING) (E) MAIN SERVICE DISCONNECT (INSIDE THE ELECTRICAL ROOM) (E) MAIN DISTRIBUTION PANEL (INSIDE THE ELECTRICAL ROOM) (E) UTILITY METER W/CT CABINET (INSIDE THE ELECTRICAL ROOM) (N) EGAUGE MONITORING UNIT (EXTERIOR WALL OF THE BUILDING) (N) AC DISCONNECT (EXTERIOR WALL OF THE BUILDING) (N) PV INVERTER - 04 (EXTERIOR WALL OF THE BUILDING) (N) PV INVERTER - 03 (EXTERIOR WALL OF THE BUILDING) (N) PV INVERTER - 02 (EXTERIOR WALL OF THE BUILDING) (N) PV INVERTER - 01 (EXTERIOR WALL OF THE BUILDING) ALL PLACARDS SHALL BE OF WEATHER PROOF CONSTRUCTION, BACKGROUND ON ALL PLACARDS SHALL RED WITH WHITE LETTERING U.O.N, PLACARD SHALL BE MOUNTED DIRECTLY ON THE EXISTING UTILITY ELECTRICAL SERVICE. FASTENERS APPROVED BY THE LOCAL JURISDICTION KEY QTY. LOCATION 1. 2 AC DISCONNECT, POINT OF INTERCONNECTION 2� 9 AC DISCONNECT, JUNCTION rl BOXES,INVERTER 3. 12 CONDUIT, JUNCTION BOXES 4. 4 DC DISCONNECT 5. 4 INVERTER 6. 2 AC DISCONNECT, U POINT OF INTERCONNECTION 7� 2 AC DISCONNECT, LU POINT OF INTERCONNECTION H. 1 POINT OF INTERCONNECTION 9. 6 AC DISCONNECT, DC DISCONNECT, POINT OF INTERCONNECTION 10. 1 POINT OF INTERCONNECTION 11. 1 POINT OF INTERCONNECTION WARNING: IT IS A VIOLATION OF THE NYS EDUCATION LAW ARTICLE 145 FOR ANY PERSON, UNLESS HE IS ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS ITEM IN ANY WAY. NOTES: ROOFTOP TRIP HAZARDS ON ROOF SHALL BE IDENTIFIED WITH REFLECTIVE MATERIAL. MARKING CONTENT AND FORMAT RED BACKGROUND WHITE LETTERING MINIMUM 3/8"LETTER HEIGHT ALL CAPITAL LETTERS, ARIAL OR SIMILAR FONT, NON -BOLD. WEATHER RESISTANT MATERIAL SUITABLE FOR THE ENVIRONMENT(DURABLE ADHESIVE MATERIALS MUST MEET THIS REQUIREMENT). sealed 03apr2025 mike@h2dc.com H2DC PLLC NY CoA#: PB -082933 ELECTRICAL ONLY PRE CONSTRUCTION DRAWING SET =W :ft = M. FREEDOM SOLAR POWER 4801 FRIEDRICH LN.SUITE 100 AUSTIN, TX 78744 P: 512.640.3864 freedoms olarpower.com SYSTEM INFORMATION DC SYSTEM SIZE: 253.17kW AC SYSTEM SIZE: 200.00kW MODULES: (522)HANWHA QCELLS Q.PEA DUO XL-G10.3/BFG 485W INVERTERS: (4)SOLAREDGE TECHNOLOGIES SE50K()S (120/208V,3PH) OPTIMIZER: (264)SOLAREDGE P1101 POWER OPTIMIZER WIND SPEED:114MPH SNOW LOAD:30PSF MINIMUM TEMPERATURE: -15,80C MAXIMUM TEMPERATURE: 32.3°C REVISION DATE DESCRIPTION REV SYSTEM LABELING REQUIREMENTS: 02/29/2024 PERMIT PLAN A 03/26/2025 INVERTER UPDATE B 1. LABELS MUST BE OF REFLECTIVE PHENOLIC MATERIAL WITH WHITE LETTERS AND RED BACKGROUND. 2. LABELS TO BE MECHANICALLY FASTENED AND PLACED AS REQUIRED PER NEC 690. 3. LABELS TO BE IN A CAPITALIZED ARIAL FONT WITH A MINIMUM OF 3/8" IN HEIGHT. 4. DC CONDUIT LABEL MADE OF DURABLE ADHESIVE MATERIALS PLACED EVERY 10 FEET AND NEAR ALL JUNCTIONS AND PENETRATIONS. 5. LABELS SHOWN FOR REFERENCE ONLY, CONTRACTOR RESPONSIBLE TO MEET LOCAL AUTHORITY AND UTILITY REQUIREMENTS. Resolution Number 25 Date IaI ri Imo 2 5 PROJECT INFORMATION NAME:CURRY HONDA YORKTOWN (COM -41603) ADDRESS:3845 CROMPOND ROAD, YORKTOWN, NY 10598 41.291126,-73.851721 APN: 35.08-1-01 AHJ:NY-TOWN OF YORKTOWN UTILITY:CON EDISON PRN NUMBER: FMS -CU -2022-877 :(ILLUMINE ELECTRICAL PLACARDS IDRAFTED BY/QC'ED BY: I THAMIZHARASAN G/MANISH A SCALE:AS NOTED REV:B DATE:03/26/2025 I E-06 M rl 00 � o O' U z U .� z LU n Z0N O Y In O 00 a��.>-P% oM a°W<� ry O a �Z It O Q 0. U>2:Z0 OV _ In It N� I.I. M V REVISION DATE DESCRIPTION REV SYSTEM LABELING REQUIREMENTS: 02/29/2024 PERMIT PLAN A 03/26/2025 INVERTER UPDATE B 1. LABELS MUST BE OF REFLECTIVE PHENOLIC MATERIAL WITH WHITE LETTERS AND RED BACKGROUND. 2. LABELS TO BE MECHANICALLY FASTENED AND PLACED AS REQUIRED PER NEC 690. 3. LABELS TO BE IN A CAPITALIZED ARIAL FONT WITH A MINIMUM OF 3/8" IN HEIGHT. 4. DC CONDUIT LABEL MADE OF DURABLE ADHESIVE MATERIALS PLACED EVERY 10 FEET AND NEAR ALL JUNCTIONS AND PENETRATIONS. 5. LABELS SHOWN FOR REFERENCE ONLY, CONTRACTOR RESPONSIBLE TO MEET LOCAL AUTHORITY AND UTILITY REQUIREMENTS. Resolution Number 25 Date IaI ri Imo 2 5 PROJECT INFORMATION NAME:CURRY HONDA YORKTOWN (COM -41603) ADDRESS:3845 CROMPOND ROAD, YORKTOWN, NY 10598 41.291126,-73.851721 APN: 35.08-1-01 AHJ:NY-TOWN OF YORKTOWN UTILITY:CON EDISON PRN NUMBER: FMS -CU -2022-877 :(ILLUMINE ELECTRICAL PLACARDS IDRAFTED BY/QC'ED BY: I THAMIZHARASAN G/MANISH A SCALE:AS NOTED REV:B DATE:03/26/2025 I E-06 powered by _ /Three Phase Inverter with Synergy Technology For the 208V Grid for North America SE50KUS INVERTERS APPLICABLE TO r / Three Phase Inverter with Synergy Technology For the 208V Grid for North America SE50KUS . rKUS MECHANICAL SPECIFICATIONV - - 5000U 50" - 3W. PE, 4W, PE w V A INSTALLATIONSPECIFNS Numcer of Sy^ergy Un15 per Invenri,venel 3 AC Max Conduit Size 2 tA' n -- -- Max AWG Una / PE 410 1110 OC Max Conduit Siae - -. - _ 1 it 3'. 2. 2' in 12 / 4 pairs, 6- 12 AWG ITC Input Inverter / Synergy Unit 3 pairs / 1 pair, Max 2 AWG; copper or alumanum Rated AC Active Output Power Maximum AC Apparent Output Power -- - - - - AC Output Line Connections Supported Cords --- - WYE: TN -C, TN -S, TN -C -S, 1'T, IT. Delta: IT AC OutpiA Voltage Minimum-Nomina,-Max,mumiti (L -N) 105 -120 -1325 O Vac AC Output Voltage Mm,mum-Nomina'-Max,mumrt (L -L) 183 - 208-.229 Vac AC Frequency Min -Nom -Mar" 59.5 - 60- 60.5 © Hz Maum Continuous Output Currant (per Phase, Pf =t1 xim Forma: 87.2m. 41. Lin x 1.38b1(inGWing frame) (2216mm x 1045mm x 35mm) " °�� Aar Dimensions (H x W x p) r M Unit: 22 z 7 x x 10 751558 z 328 x 273 in /rem -17 224x11.6l360x 560x 295 Synergy Manager: t41 /Power Optimizer 1 A Weight •" Weign: 6421bs (29.1 k9) FlomCaver 0.08tn(2.0mm)inejnrally pie-sirl?£sed glass wolf -•o ^+'.••-+ II'l--•i .a.,q•� enlltiellp:IbafeCMOWgy a vna.n � u vas Power Optimizer O/� For North America -40 to +140 / -40 to -600s' T /'C Taal Harmonic Distention - __ .{ Back Covo, 0.08in(20mx°)samltempefedRims .. Power Factor Range _ _ ./-02 to 1 Nese < 6/ dBA INPUT Protection RatIng "- Manmum DC Power IModuk STC) Inverter / Synergy Unit 87500 / 29165 r m I4er.., statin O.ANTUM Wier half CHl3 �� ��� Transfamel-less, Ungrounded Yes For North America (Si rty t%MW dPrdIWIininrnrdtKx'. rerq'tp tllP tPrN'Lt. Mrxe i1P-rahr'n 1'rrtati_-al NrY°!NMhArerA-.�1 P1101 Vol: Operating Voltage Range 340 - 600 Vdc Manmum Input Cuncnt 3x46,5 Adc Junction box OBx� 1.262361nxa59-G.71.n O Ground -Fal@( Isolation Daemon 167xO sens4Mly per synergy Unity' �" CEC weighted Efnciencv 97 Power •• 1 W ADDITIONAL FEATURES 5uppated Communication Interfaces"' 2 x RS485. Etnenret. w-ri (optional), Cellular (opt'o:ral) Smart Energy Management Export Limitation (53-101 mmx3260wrini18mm),IP67.wdh bypassdiodes Etrw Arc Fault Protection Built-in, User Configurable (According to UL1699B) Phosovoltarc Rapid Shutdown System NEC 2014, 20T7 and 2020, Built-in PID Rectifier Nighttime, built-in urge Prentice (pons l+2) Il, replaceable. integrated AL, DC85 type fxrd AC, a Surge Protection type If. fek1 rdolaceable, Integrated DC Fuses (Single Pole) 25A, integrated er or bi-facial modules) DC SAFETY SWITCH I,, STANDARD COMPLIANCE _n lit Cable 4mmsSolar cable, (.)z27.6w(7a0mm)(-)>13.8in(350rnm) xi � J Contractor Stautill MCA Evu2.. Hernvha O CEL,.S HOC4. IP63 _ Eaw.. Grid Connection standards IEEE 1547-2ot8, Rude 21, Rine 14 (HI) M P1101 25)71 INPUT - I n: it DC Ppyer" :;,rn� :ion Me:hod Absolute Maximum input Voltage (Voc at IrnvEst Imperatore) 11gO _ _ 1, . ,,p.1 for renes rarra'ted modules 125 - -- Vdr U MPP, Operating Range US -105 Vdc . • ,.3 BFG ELECTRICAL CHARACTERISTICS POWERCLASS 470 448 480 486' • • • - Maxrmum5hcriCrcmtCurrent (Isc) Manmum ShortG (UI CIIr(enI Input {LSL) r - _ 14.1 - - - Attic Ace 470-485 , � • • e • • . RELIABILITYWITH EXCELLENT 8 ADDITIONAL 1 -allru.crs • Q �' ' Il TOP BRAND PV / ( \ 2020 0 DCELLS '---- - --- i �JRMANCE Ai STANDARD TEST CONDITIOMS SI:. F.PID ESTU (POWER TOLLI24NCE'!'�b ::. J5196 - - O Maximum EII pent 93 S % - - V -:-,•,roti fF =pry _ G OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED 70 OPERATI G SOLAREDGE INVERTER) Mie r - _ -.- _ Mm ai _ Vic OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOL lREDGE INVERTER OR SOLARED E INVERTER OFF) T- - - - -- -------- - Power at MPP+ Ps ., IW( 470 51-- 435 5196 480 5250 485 - - -W JAI 1., 70 5141 1175 Short Circuit Curent• 1412 12.14 -- 485 li - --_. -_ --_-- 11 - _-- E Openo""t Volta V . E 9s' tS', •sl y3.1L1 5315 53.34 53.39 63.58 53.63 a3C5 2 12.21 5,,.82 E Current In MPP „w (A] 105 11.50 10.55 11.54 10.59 11.58 10.63 1163 VohageatMPP Veit IV) 4473 44.72 45D3 45.02 45.33 45.32 Effiaency, q I%) x203 -222 Z05 224 z207 1227 4583 x209 4562 229 Vlelo Security STANDARD COMPLIANCE _ Bifadektyd Pu,., aitly_70%x5%•BHeaelltygrven foneat sole irradiation an tmdSTC (kdntssde)-Acca dingto IEC 60904 12 _-. 1. - Comixiant with NEC 2014.2017.,!QJ 'Mxxaw,ramxmt takroncea Pn•x3%;I.,.v<e5%wSIC: 1000vvw,;"m BST[: l00DW/rN+y.135W1>.4P7C%s5%1_-_c,:-.V 1.h aeepdNgbIFCBC904-3 ' BIFACIAL ENERGY YIELD GAIN OF UP TO 20% Bi}acial Q,ANTUM solar tails with zero gap cell layout make efficient use of light shini on the module rear -side for radical) Improved LCOE r'9 Y� P° MINIMUM PERFORMANCE At NORMAL OPERATING CONDITIONS, NMOP Powere;MPP P,mr lw9 353:8 3576 3874 E Short Circuit Cument h_ (A) 8.89 8.92 8.96 - 2 c open Circuit Voltage V1 IV) 50.04 50.27 .;-0AS 3651 _. 8.99 50.72 m I Vi FCC Part IS Class A, leC610Co-6 2. IK61000 6 3 Safely IEC62VJ-1(class Isafely), UL1741, UL3741, CSA C22 20107 1 - I x,,,A 0494 V 0, UV rsyi9.am _- 115 Yes INSTALLATION SPECIFICATIONS - - - CLANTUM LOW ELECTRICITYGENERATIONa COSTS separationQ0t)C� i Current at MPP I_ JAI 8_27 a30 834 Yohagc at MPP V,µ., [V) 4277 4.3 M. '33r >, rJ ... _ 8.37 4363 _. _ mwuaole SoarEd Inyerlers All comme,cial mice Phase invartm iyslem Vq e _ 1000 M;ufmumst'Al. �- - ;W xLxHI 129x1621/2.34 x232 L - wiirgwithG.AONT UM Telchnology for hiheryeldper Surface area, lower rg 9Y 9 N PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE -_. _. - - irght u n�wxJm - BOS roxilr, hilifte, power classes, and an toy rale of up to 21.2%. _ - - . _ � PV the level hpM W 9{2 CD INNOVATIVE ALL-WEATHER TECHNOLOGY Optimal yields, whatever the weather with excellent IOW-ligrd ar,d temperature behavior. 0,45% Ual Poelor up to �at :'. slv ... _ _ - _.. 0 % ^Thr e y `s Powenlp m 3o yams. +r �' • - <- a power optimization at module The most cost-effective solution for commercial and large field installations '+ Dixon, 2 ; 161 Output Wire Tyoe f ConnMor Double insulated. MC4 outpul Wife Length 2.4/7.0 m / h ( Jj� ENDURING HIGH PERFORMANCE Long-term yield Security With Anti LID and Anti PIC Techno -, 9 Y Y ogY Hot -Spot Protect and Traceaule Quality Tra.01i FRAME FOR VERSATILE MOUNTING OPTIONS High-tech aluminum alloy frame protects from damage, enables use of a wide range of mounting structures and is certified regarding IEC'> for high snow (640013a) and wind loAns(240OPe). A RELIABLE INVESTMENT Ductile glass snCxdUled85ign enables extended lifetime with 12 -year product warranty and improved 30 -year performance warranty. All calls wmmmeaasremmuawarv> e. es. Fuk wmretrom In aecordarrca w4r •° .aa I.I.eir let rap° uaa me wenanty teens of u,a ocELts _ > a saws argantsation oly«nreapectiye fO'x`try - - typ;rd roija pertOrmancE .:nch':r law intsoonce conaiuor=rn -' - - - compen son to STC ccrrdmans f25•C. 1000W/m) - -- TEMPERATURE COEF COEFFICIENTS =o.04 r�mc,"at aCael;iclen:oty.. $ t%tKl y: I%7x) -0.34 Nominal Module Operating temperature NMCT l'FI -0.27 108x5.4(4233 -C) $ 2 o Q / Specifically designed to work with SolarEdge / Inverters ! / High efficient with module -level MPPT, for g y maximized system energy production and revenue, and fast project ROI / / Superior efficiency (99.5%) / ! Balance of System cost reduction; 50%less cables, fuses, and combiner boxes; over 2x longer string lengths possible Fast installation with a single bolt Advanced maintenance with module -level monitorin g Module -level voltd 9 a shutdown for installer and firefighter h ter safety Meets NEC requirements for arc fault g protection (AFCO and Photovoltaic Rapid Shutdown System (PVR55) OperamxaiempeamreRan - - - -- -- PrOtR. ]itxlR 40tocB5/ 40io.185 _ --- _ -_-- P660/ 6P ------ - -'C IT - tlr ro alive arum try % w R -.<a Maw+drre mxhee al 8<Wli ria eae<d tre P. upcmcel Fxed nWtO[Vaaer N,xib wsnuP ro.sa.pcxve tcM,ra art, IDY,aed. r Iw [� 1M [9r=+{�ai<revf lO hlC - L ,. ,ies auie .;vv •Ice'seraechi -,4rNaalxrM1'a.aes.mw,.wcmxxc,.rxcxxaxme a:mxxvrr. r,.,«wo-ary eraas. PV System Deci 1;� Inve • Opnmi¢en Pilo! PROPERTIES FOR SYSTEM DESIGN C p Mi nium '111r" Poser Opumlzers 8 7C W 34 - u /daxmmm system Voltage V:,, (V) 1500 PV module classification Lerryln wMoades 1s >4 n n _ Maximum Serial Fuse Rating (ADC) 20 Fire Rating: basad on ANSI /UL 61730 TYPE 29' 1. Maximum String Pireeropraizers 30 3V 30 3C Max. Design Load. Push/ Puts (lbs/Itj 75(3600P8)/33 f1600Pa) Pemlleted Module Temperature -40°F us, to Length Pv Modules 60 60 60 60 Maximum cm1iroms Pcwrc.per String 7200 BKG 15300 15300 w - A- I lest corelnons acclrdirg w iECI TS 62Ba4-1.2015 meniod R r -1500v. 168hpnclucing posnrWtment according to IEC 61215-1-1 Ed. ZO op, " See Asia sheet orirear kir lumber lafotmatpn Max. Test Lond. Push/ Pull, flbs/fPI 113(5400Ps)/50(2400Pa) oto Continuous Duty (-40°C up to -85°C) -- - see Inat63ation Manual ° Naty Type is elmaar wType3 but with mai®ec frame -- --- - - ---- 1 sMing - 8400 Maximum Aimed Conri raw Pow�� e) per Stri 2smrgs w more -9800 1 s!m'g - 10020 htrmg -1x;40 2Ari scvrnore-12020 2soingscrmpre-20300 2 strings w Anil -17550 W 3so swmscre-20300 Parallel Strings of Different Lang" or Orientanms Yes QUALIFICA- ANDCERTIFIC/ THE IDEAL SOLUTION FOR: Utal7ao. CE ccl"ll. - .. Maele l Diffinmem Numbe, or totality Oplimzes Allowed Bdxare the Sh(xtesl and Lorvgest String 5 Power Optimizers Q.. IiC 412I6:701fi.ifCBV30�n118. (�� US.PwmlR a894.?lb V F Corrimled to the Same Inverter Unit _ eo:xr tea) G .Is ` •rte rIarx,u,a apply la Svyiar, ones u!epurvakr,lp[rsx�+r rdliryS that me Pan of the alryi SYMgy IeCM'dogy,rrvxttl, Ce.Nlkaeonaa«evu „.:::, aaeaclr slrxg dPoae OlNvnfer may lR iPnra[iad rU3L'r9k P"J mXa,k+il rieaCr Poter aptimiiersxavenad lOa14aw Whbd,wo'2l it is the cMyPv-tt rkltunter CMn•eaeAlo a fagk'PYrMaJ< t,h<gr r9 Note isiffpn lnatruclionamualbafolbwed, Selma lratrr.1 ". ac contact cutercMlcelvel department for furthesinlorrtiallOn On oppmyad Installation a"n53 at. r Dznn veil fl ee rrFau 20aV inrtmrs i. hniMtl lli[Ih[ ' E -fvr rrificsmn. IG' rc eaven ne"re S*C Wr:x per Srnp utvq+ p"r p ,p+l:, usinr'�iy'E,+ a fu•wvier Engineered in Germany CEAs Menvha O CELLS America Inc. -i')O, +wre.CA9261H,USA ITEL +19497n859961EMAIL !ngarypns.a-tMS ComI WEB wwWq-reysw solaredge.com solar . :sa.mae neersklartIldA""plstiti'wuamr'c tie 5a'wseaq°oerxnap s+sdKEar>E,reuaenrmn weg�. i ,.�,ie:d Rixtase lisrmosa. Irc .. .�>,neae<i..ilarxewxr.e!.r°n.:.w®rixiiaw.xcx.+,or<hwx..<r.wr..�a.saa.asamassw,Lzair<r,., - .,rr�nr«� ROMS Three Phase Inverter Z C with Synergy Technology m••MODEL For the 208V Grid for North America SE50KUS n VEAR 6 WARRANTY LA x _ - - N� ° Powered by unique pre -commissioning process for rapid system installation / Pre -commissioning feature for automated / Built-in arc fault protection and rapid validation of system components and wiring shutdown during the site installation process and prior to grid connection / Built-in PID mitigation for maximized system performance / Easy 2 -person installation with lightweight, / Monitored* and field -re -replaceable sure modular design (each inverter consists of p 9 protection devices, to better withstand surges 3 Synergy units and 1 Synergy Manager) p 9 caused by lightning or other events / Independent operation of each Synergy unit / Built-in module -level monitoring with Ethernet enables higher uptime and easy serviceability y or cellular communication for full system / Built-in thermal sensors detect faulty wiring visibility ensuring enhanced protection and safety solaredge.com s o l a r _• /Three Phase Inverter with Synergy Technology For the 208V Grid for North America SE50KUS INVERTERS APPLICABLE TO r / Three Phase Inverter with Synergy Technology For the 208V Grid for North America SE50KUS . rKUS OUTPUT - - 5000U 50" - 3W. PE, 4W, PE w V A INSTALLATIONSPECIFNS Numcer of Sy^ergy Un15 per Invenri,venel 3 AC Max Conduit Size 2 tA' n -- -- Max AWG Una / PE 410 1110 OC Max Conduit Siae - -. - _ 1 it 3'. 2. 2' in 12 / 4 pairs, 6- 12 AWG ITC Input Inverter / Synergy Unit 3 pairs / 1 pair, Max 2 AWG; copper or alumanum Rated AC Active Output Power Maximum AC Apparent Output Power -- - - - - AC Output Line Connections Supported Cords --- - WYE: TN -C, TN -S, TN -C -S, 1'T, IT. Delta: IT AC OutpiA Voltage Minimum-Nomina,-Max,mumiti (L -N) 105 -120 -1325 O Vac AC Output Voltage Mm,mum-Nomina'-Max,mumrt (L -L) 183 - 208-.229 Vac AC Frequency Min -Nom -Mar" 59.5 - 60- 60.5 Hz Maum Continuous Output Currant (per Phase, Pf =t1 xim 139.5 Aar Dimensions (H x W x p) r M Unit: 22 z 7 x x 10 751558 z 328 x 273 in /rem -17 224x11.6l360x 560x 295 Synergy Manager: t41 GPDI Thteshokl 1 A Weight Synergy UrM 704132 5 Malt r 396/ 18 Ib / kg UMI4y, Mon4aiv standing Protection, Conigurable Pcxw Factor, Country Conf unable Tbres*dds vas O/� Operating Temperature Range -40 to +140 / -40 to -600s' T /'C Taal Harmonic Distention - % Coolxg Fan (user rLglaceatNe) Power Factor Range _ _ ./-02 to 1 Nese < 6/ dBA INPUT Protection RatIng NEMA 3R Manmum DC Power IModuk STC) Inverter / Synergy Unit 87500 / 29165 W Mousing Brackets prov,eled Transfamel-less, Ungrounded Yes w/ (Si rty t%MW dPrdIWIininrnrdtKx'. rerq'tp tllP tPrN'Lt. Mrxe i1P-rahr'n 1'rrtati_-al NrY°!NMhArerA-.�1 Maximum Input Voltage DC- to DC- 600 Vol: Operating Voltage Range 340 - 600 Vdc Manmum Input Cuncnt 3x46,5 Adc Reverse -Polarity Protection Yes O Ground -Fal@( Isolation Daemon 167xO sens4Mly per synergy Unity' �" CEC weighted Efnciencv 97 % Nighttime Poll Corleumplion 12 W ADDITIONAL FEATURES 5uppated Communication Interfaces"' 2 x RS485. Etnenret. w-ri (optional), Cellular (opt'o:ral) Smart Energy Management Export Limitation Inverter Commissioning Wit" the SetA)]p mobile application using Wilt -in Wi-Fi access Pont for local connection Arc Fault Protection Built-in, User Configurable (According to UL1699B) Phosovoltarc Rapid Shutdown System NEC 2014, 20T7 and 2020, Built-in PID Rectifier Nighttime, built-in urge Prentice (pons l+2) Il, replaceable. integrated AL, DC85 type fxrd AC, a Surge Protection type If. fek1 rdolaceable, Integrated DC Fuses (Single Pole) 25A, integrated _ Pre co Willie^Ing Built-in a' DC SAFETY SWITCH I,, STANDARD COMPLIANCE <, viy .A 16998, 1, 01A L UL:741 SA. U1.1141 SB, UL'i998, CSA C222+107.1. Canadian AFC) acmrdn tv 111 M-07 Grid Connection standards IEEE 1547-2ot8, Rude 21, Rine 14 (HI) M Emissions FCC pan 15 class n) set °rr<rregionaiscm asweat<c°ntanSolaredge,uPrwL IU Where permitted M Iwai tv9u0i 7 crape aKa dMMMe gidndcommunkaa nopeoe,mwmar mina .n n-nxbrtheuet„rcP(rrrax.:o mwnl a rretawwmPwaaaaavaeL (4) Not salaaeFor P/WSEsnKniia.(�x. WARNING: IT IS A VIOLATION OF THE NYS EDUCATION LAW ARTICLE 145 FOR ANY PERSON, UNLESS HE IS ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS ITEM IN ANY WAY. Resolution Number Date to l g l a o s s 111111, - 11111111' 11111111/ 11♦ 11■ 11■ 1111 FREEDOM" SOLAR POWER 4801 FRIEDRICH LN.SUITE 100 AUSTIN, TX 78744 P:512.640.3864 freedomsolarpower. corn SYSTEM INFORMATION DC SYSTEM SIZE: 253.17kW AC SYSTEM SIZE: 200.00kW MODULES: (522)HANWHA QCELLS Q.PEA DUO XL-G10.3/BFG 485W INVERTERS: (4)SOLAREDGE TECHNOLOGIES SE50KUS (120/208V,3PH) OPTIMIZER: (264)SOLAREDGE P1101 POWER OPTIMIZER WIND SPEED:114MPH SNOW LOAD:30PSF MINIMUM TEMPERATURE: -15.81C MAXIMUM TEMPERATURE: 32.31C PROJECT INFORMATION NAME:CURRY HONDA YORKTOWN (COM -41603) ADDRESS:3845 CROMPOND ROAD, YORKTOWN, NY 10598 41.291126, -73.851721 APN: 35.08-1-01 AHJ:NY-TOWN OF YORKTOWN UTILITY:CON EDISON PRN NUMBER: FMS -CU -2022-877 :(' ILLUMINE i SPEC SHEET - 01 IDRAFTED BY/QC'ED BY: I THAMIZHARASAN G/MANISH A SCALE:AS NOTED I REV:8 DATE:03/26/2025 J SS -01 REVISION DATE 103/26/2025 DESCRIPTION REV 02/29/2024 PERMIT PLAN A INVERTER UPDATE B O Brill V 01 1 LA O H O} L r U Z n ZON O/� �YU) LV/ Oopro; 00 a�lilt.�-� d°�a(14 N w/ O 1-4 lL r -i Q N Z O p �" Z O u _ IT 00 � M U PROJECT INFORMATION NAME:CURRY HONDA YORKTOWN (COM -41603) ADDRESS:3845 CROMPOND ROAD, YORKTOWN, NY 10598 41.291126, -73.851721 APN: 35.08-1-01 AHJ:NY-TOWN OF YORKTOWN UTILITY:CON EDISON PRN NUMBER: FMS -CU -2022-877 :(' ILLUMINE i SPEC SHEET - 01 IDRAFTED BY/QC'ED BY: I THAMIZHARASAN G/MANISH A SCALE:AS NOTED I REV:8 DATE:03/26/2025 J SS -01 REVISION DATE 103/26/2025 DESCRIPTION REV 02/29/2024 PERMIT PLAN A INVERTER UPDATE B PROJECT INFORMATION NAME:CURRY HONDA YORKTOWN (COM -41603) ADDRESS:3845 CROMPOND ROAD, YORKTOWN, NY 10598 41.291126, -73.851721 APN: 35.08-1-01 AHJ:NY-TOWN OF YORKTOWN UTILITY:CON EDISON PRN NUMBER: FMS -CU -2022-877 :(' ILLUMINE i SPEC SHEET - 01 IDRAFTED BY/QC'ED BY: I THAMIZHARASAN G/MANISH A SCALE:AS NOTED I REV:8 DATE:03/26/2025 J SS -01 eGauge Core Specifications Model: EG4115 Measurement AC Voltage: Ll: 85-277Vrms (Y: L -N, A: L -L) L2: 0-277 Vans L3:0-277 Vrms DC Voltage: 42 Vrms Power: 9-60 Vdc Measurement:-60-60Vdc Current: 15 sensor ports 6900A max Sensor ports isolated from digital and high voltage Frequency: 50 or 60 Hz Logging Values: V, A, W, Wh, Hz, VA VAr,THD, deg Power Draw: 12W max, 2W typical 2 5V USB Ports @ 1A rnax Accuracy: ANSI C12.2 - 0.50/o Compliant Environment Conditions Operating Temp: Max Altitude: Max Humidity: Meas. Category: Location LCD Scr USB Ports+ Ethernet ------ I AC Voltage Input DC Voltage Input Data Logger Capacity Register Count: Granularity: d;: ratio � %ovg) 15 Sensor Ports 64 (data storage points) 1 hr/1 sec 1 yr/1 minute 10 yrs/15 minute Device Lifetime/1 day -30°tn 22'to158°F) Safety and Regulatory 4000m (13,123ft) Safety: EC/UL 61010-1 Ed. 3.013:2010 80% LIP to 31'C CE: IEC 61000-6-1 Ed. 3.0 B:2016 Overvoltage Category III IEC 61000-6-3 Ed. 2.1 B:201.1. Open type indoor device Pollution Degree: 2 FCC: FCC Title 47 CFR Part 15 - Subpart B Class B ICES -003 Information Technology - Equipment Class B eGauge Core Specifications General Dimensions Warranty: 2 years, 5years Communication Homeplug AV: Compatible with HomePlugAV adapter within -100ft. on same phase as Ll terminal Ethernet: IEEE 802.3 - LAN User Interface Compatible Google Chrome browsers: E(refox up -to -dot" Safari versions supported) Internet Explorer Enclosure Material: Dimensions: Weight: FRABS 17x8x4.6cm ,6.7x3.15x1.81in) 300g (0.66lbs) i e` [64115 Mmer. Pale levee.. Snrvar 11 WARNING: IT IS A VIOLATION OF THE NYS EDUCATION LAW ARTICLE 145 FOR ANY PERSON, UNLESS HE IS ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS ITEM IN ANY WAY. Resolution Number 2-5 Date I q I 0 b 5 - FREEDOM"' SOLAR POWER 0801 FRIEDRICH LN.SUITE 100 AUSTIN, TX 78744 P:512.640.3864 freedomsola rpower.com SYSTEM INFORMATION DC SYSTEM SIZE: 253.17kW AC SYSTEM SIZE: 200.00kW MODULES: (522)HANWHA QCELLS Q.PEAK DUO XL-G10.3/BFG 485W INVERTERS: (4)SOLAREDGE TECHNOLOGIES SE50KUS (120/208V,3PH) OPTIMIZER: (264)SOLAREDGE P1101 POWER OPTIMIZER WIND SPEED:114MPH SNOW LOAD:30PSF MINIMUM TEMPERATURE: -15.8°C MAXIMUM TEMPERATURE: 32.3°C SOLAIRSTACK • 1Shipping Data DESCRIPTION REV How is Solar Stack attached to panels? PERMIT PLAN A FOP i SKU units per pallet Weight Per Unit Weight Per Pallet Dlmenslons Rails are not required. frI 55.8 t.0 1.81 cs � � Ls - b - MIT 55 -12 100 2.791bs 7,=.0 Ib, 48 x 40"x 21" 1 N o ,1 MIAMI-DADE COUNTY SS -a TSL B TSH (sS Tilt Kit) Z'0 °A R TSI : ICC SG y TSIi TS ' 174 o'-. T54-,. i94 :r: 41_.5 h:. 48" v 4c"21" I— U APPROVED 55 -Foam 30 26 Kits 38 lbs 1,040 Its 48" x 40" x 36" " LU Z ss -Foam 100 12 Kiss 114 bs How many Solar Stacks per panel? 1,390 Thr, 50" > 36" x 43" What is Solar Stacker 1C Cl )r,' I 'a 11ci l — _ - wd darn& hlle mecting -_h. J. Ill ' _ SPI ,: - All it 2', 1 4 EL So Lir Vnck ;n,nrnr ?4 ce 17 e { 1 Y ► Foam r � Each container voeiUlr 48 lbs. It is preas',t�lnbled and ready to use. Each container has O paw enough adhesive to mount between 125-175 g ( qty) SS -8 and SS Til[ Mounts, or (85-115 qty) SS -12. 0 � • 1 r. F TEMPERATURE GUIDELINES = In • Chemical Storage Temperature 150-100"F (10-38"C) � Outside Appiication Temperature 140-100'F (4-38'C) Internal Chemical Application Tempe•ature 170-90-F (21-32°C) How does it work? • Surface AppFcation Temperature (Substrate) I z,0 -100'F (4-38°C) . I. I , i �,. I �I }, ,(. i 1,. I- rI . _ � 'InternalchemimltemoerofuTe mustr>a 0f laas["'0"F ashen ooplyin�foom. Stare :n Cemperarures �0"F or obcw during vnn[er months. I' T Aa Once opened foam kits can be re -used out they have an expiration date of 30 days. 8 - 'SOtaf Stock Should t. ;rn railed by a Certified x>lur c;xk 1r.Sta110 lfyoud like to become a Carihod insroller a - email or call us Coda, - — Foam Primer Autiesive prmc'rs-nl-St. oQ applied to all single ply membranes (TPO, EPDM, PVC, etc.) What orientation are panels mounted? after the roof has been cleaned and is dry. please refer to our "coatings and primer" ;rochure for more Information, or email us at info@solarstack.com • _ Panels can be mounted u I I J'„ � I Solar Stack mounts. > Products Panolc must be mounted in landscape i:- i.:,ing Solar Stack tilt mounts. 3' ],I n -,"t 1 ilt Mount, S'slope ICP Polyset AH -160 a (SKU# SS -B TSL & PrcPack3G -- SS-8TSH) (SKUrtSS-Foam) ® SOLARSTACK SOLARSTACK ® SOLARSTACK 10. AL 1Id3:1 solarstack.com I F377-757-7822 I Contact us at info@solarstack.com t� ( solarstack.com Contact us at info@solarstack.com 4° solarstack.com 877-757-7822 1 ConraCtL)',atinfo@solarstack.com40 WARNING: IT IS A VIOLATION OF THE NYS EDUCATION LAW ARTICLE 145 FOR ANY PERSON, UNLESS HE IS ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS ITEM IN ANY WAY. Resolution Number 2-5 Date I q I 0 b 5 - FREEDOM"' SOLAR POWER 0801 FRIEDRICH LN.SUITE 100 AUSTIN, TX 78744 P:512.640.3864 freedomsola rpower.com SYSTEM INFORMATION DC SYSTEM SIZE: 253.17kW AC SYSTEM SIZE: 200.00kW MODULES: (522)HANWHA QCELLS Q.PEAK DUO XL-G10.3/BFG 485W INVERTERS: (4)SOLAREDGE TECHNOLOGIES SE50KUS (120/208V,3PH) OPTIMIZER: (264)SOLAREDGE P1101 POWER OPTIMIZER WIND SPEED:114MPH SNOW LOAD:30PSF MINIMUM TEMPERATURE: -15.8°C MAXIMUM TEMPERATURE: 32.3°C PROJECT INFORMATION NAME:CURRY HONDA YORKTOWN (COM -41603) ADDRESS:3845 CROMPOND ROAD, YORKTOWN, NY 10598 41.291126,-73.851721 APN: 35.08-1-01 AH1:NY-TOWN OF YORKTOWN UTILITY:CON EDISON PRN NUMBER: FMS -CU -2022-877 :('ILLUMINE SPEC SHEET - 02 DRAFTED BY/QC'ED BY: THAMIZHARASAN G/MANISH A SCALE:AS NOTED I REV:B DATE:03/26/2025 I SS -02 REVISION DATE DESCRIPTION REV M PERMIT PLAN A 03/26/2025 INVERTER UPDATE H 111.0 T••1 00 MIT 01 1 N o ,1 O� I— U z U".N., z LU Z INS! 11 O n 3YIn o^ a000 Cd EL < ce Ce 0 Q r ct a N O paw Z 0 OC = In qTm D U PROJECT INFORMATION NAME:CURRY HONDA YORKTOWN (COM -41603) ADDRESS:3845 CROMPOND ROAD, YORKTOWN, NY 10598 41.291126,-73.851721 APN: 35.08-1-01 AH1:NY-TOWN OF YORKTOWN UTILITY:CON EDISON PRN NUMBER: FMS -CU -2022-877 :('ILLUMINE SPEC SHEET - 02 DRAFTED BY/QC'ED BY: THAMIZHARASAN G/MANISH A SCALE:AS NOTED I REV:B DATE:03/26/2025 I SS -02 REVISION DATE DESCRIPTION REV 02/29/2024 PERMIT PLAN A 03/26/2025 INVERTER UPDATE H PROJECT INFORMATION NAME:CURRY HONDA YORKTOWN (COM -41603) ADDRESS:3845 CROMPOND ROAD, YORKTOWN, NY 10598 41.291126,-73.851721 APN: 35.08-1-01 AH1:NY-TOWN OF YORKTOWN UTILITY:CON EDISON PRN NUMBER: FMS -CU -2022-877 :('ILLUMINE SPEC SHEET - 02 DRAFTED BY/QC'ED BY: THAMIZHARASAN G/MANISH A SCALE:AS NOTED I REV:B DATE:03/26/2025 I SS -02 Grounding? Imo. IRONRIDGE UFO Family of Components Simplified Grounding for Every Applicatioi The UFO family of components eliminates the need for j separate grounding hardware by bonding solar modules directly to IronRidge XR Rails. All system types that feature the UFO family -Flush Mount, Tilt Mount and Ground Mount -are fully listed to the UL 2703 standard. UFO hardware forms secure electrical bonds with both the module and the rail, resulting in many parallel grounding paths throughout the system. This leads to safer and more reliable installations. Wire Management? r ron) micro inverte r. Inverter or wire management A' I dips on the under side panels. Stopper Sleeve Universal Fastening Object (UFO) The Stopper Sleeve snaps The UFO securely bonds solar modules to XR onto the UFO. convertin it into Rails. It comes assembled and lubricated. and j M Nj`;'� a bonded and clamp. g can fit a wide range of module heights. O Paint Foam Eacn exposed Sclar Stack (exposed to the sun, outside of array) must be coated with an outdoor acrylic paint: for UV protection. System Diagram O UFO C Stopper Sleeve • Grounding Lug m BOSS" Splice J— Ground Wire Q Approved Enphase microinverters can provide equipment grounding of IronRidge systems, eliminating the need for grounding lugs and field installed equipment ground conductors (EGC). A minimum of two microinverters mounted to the same rail and connected to the same Engage cable is required. Refer to installation manuals for additional details. UL Certification WARNING: IT IS A VIOLATION OF THE NYS EDUCATION LAW ARTICLE 145 FOR ANY PERSON, UNLESS HE IS ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS ITEM IN ANY WAY. FREEDOM SOLAR POWER 1801 FRIEDRICH LN.SUITE 100 AUSTIN, TX 78744 P: 512.640.3864 f re ed oms of a rpo we r. co m SYSTEM INFORMATION DC SYSTEM SIZE: 253.17kW AC SYSTEM SIZE: 200.00kW MODULES: (522)HANWHA QCELLS Q.PEAk DUO XL-G10.3/BFG 485W INVERTERS: (4)SOLAREDGE TECHNOLOGIES SE5OKUS (120/208V,3PH) OPTIMIZER: (264)SOLAREDGE P1101 POWER OPTIMIZER WIND SPEED:114MPH SNOW LOAD:30PSF MINIMUM TEMPERATURE: -15.8°C MAXIMUM TEMPERATURE: 32.30C A-1211"MO e1u111 Resolution Number 2s-J3— Date (01 Ci Ii REVISION \� DESCRIPTION The IronRidge Flush Mount, 02/29/2024 '-� A 03/26/2025 INVERTER UPDATE B 00' Tilt Mount, and Ground Mount 7XRails J J XR1000 fJnly BOSS'"' Splice Systems have been listed to UL Ronded smin,ral splice - 2703 by Intertek Group plc. topper J J J -- i••� connects rails with buiibin Y bonding tenth. No bots or BOS$TM' $10011fpIICe J J N/A 0• hardware needed. UL 2703 is the standard for Solar Stack k is the fastest and simplest installation system on the market evaluating solar mounting Lugs Groundin Lu s Grounding 1 per Row 1 per Row t per Array ' l u : � erraca cl . , , swlh:w . I _ I � r r, I -- systems. It ensures these devices Microi Enphase - M250-72, M250-60, M215-60, C250-72 74 00 pi considered a cert fled solar snack Ir-- - o_I r r= on I . �,i Io,:., . will maintain strong electrical and & Power Darton - MIG240, MIG300, G320, G640 1 p Grounding Lug Bonded Attachments mechanical connections over Solarkdge - P300, P320, P400, P405, P600, P700. P730 c G 74 - t.r �� A single Grounding Lug connects an entire row The banding bolt attaches an extended period of time in re Rating Class A Glass A NIA SO LAR STAC K Of PV modules to the grounding conductor. and bonds the L -foot to the rail. It is installed with the extreme outdoor environments. LOiMptimizers Tested or Evaluated with over 400 Framed Modules U Z same socket as the rest of the system- O Go to lronRidge.com/UFO OdUles ' Refer to installation manuals for a detailed list. W � Z � 3: fV r1 Z O n rw solarstack.",zn I 877-75/--7822 ) Contact us at info@solarstack.com 4 O 3 Y 1A O 01 oro 4) 202D IronRidg% Inc. All rights ro%arved. Visit www.fronridge.com or call ,e, a aF' Yrs >t; a cc o Ce O Q IM Z N a 0 Q °o Z0 O� = IA RT �Co M D V A-1211"MO e1u111 Resolution Number 2s-J3— Date (01 Ci Ii PROJECT INFORMATION NAME:CURRY HONDA YORKTOWN (COM -41603) ADDRESS:3845 CROMPOND ROAD, YORKTOWN, NY 10598 41.291126, -73.851721 APN: 35.08-1-01 AHJ: NY -TOWN OF YORKTO W N UTILrrY:CON EDISON PRN NUMBER: FMS -CU -2022-877 :(ILLUMINE i� SPEC SHEET - 03 IDRAFTED BY/QC'ED BY: I THAMIZHARASAN G/MANISH A SCALE:AS NOTED I REV:B DATE:03/26/2025 I SS -03 REVISION DATE DESCRIPTION REV 02/29/2024 PERMIT PLAN A 03/26/2025 INVERTER UPDATE B PROJECT INFORMATION NAME:CURRY HONDA YORKTOWN (COM -41603) ADDRESS:3845 CROMPOND ROAD, YORKTOWN, NY 10598 41.291126, -73.851721 APN: 35.08-1-01 AHJ: NY -TOWN OF YORKTO W N UTILrrY:CON EDISON PRN NUMBER: FMS -CU -2022-877 :(ILLUMINE i� SPEC SHEET - 03 IDRAFTED BY/QC'ED BY: I THAMIZHARASAN G/MANISH A SCALE:AS NOTED I REV:B DATE:03/26/2025 I SS -03 SAFETY PLAN: LAY DOWN AIX. SCALE: 1"=40' -0' - WARNING: IT IS A VIOLATION OF THE NYS EDUCATION LAW ARTICLE 145 FOR ANY PERSON, UNLESS HE IS ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS ITEM IN ANY WAY. CROMPO'VD ROAD FIELD NOTES: FREEDOM' SOLAR POWER 4801 FRIEDRICH LN.SUITE 100 AUSTIN, TX 78744 P:512.640.3864 freedoms ola rpower. co m SYSTEM INFORMATION DC SYSTEM SIZE: 253.17kW AC SYSTEM SIZE: 200.00kW MODULES: (522)HANWHA QCELLS Q.PEA DUO XL-G10.3/BFG 485W INVERTERS: (4)SOLAREDGE TECHNOLOGIES SE50KUS (120/208V,3PH) OPTIMIZER: (264)SOLAREDGE P1101 POWER OPTIMIZER WIND SPEED:114MPH SNOW LOAD:30PSF MINIMUM TEMPERATURE: -15.8°C MAXIMUM TEMPERATURE: 32.3°C LOADING ZONE I N Resolution Number .7,5-13 Date L I R I 1,O -S DATE DESCRIPTION REV 02/29/2024 PERMIT PIAN A ftt/>ri/7f175 TNVFRTFR UPDATE B PROJECT INFORMATION NAME:CURRY HONDA YORKTOWN (COM -41603) ADDRESS:3845 CROMPOND ROAD, YORKTOWN, NY 10598 41.291126,-73.851721 APN: 35.08-1-01 AH1:NY-TOWN OF YORKTOWN UTILITY:CON EDISON PRN NUMBER: FMS -CU -2022-877 :('ILLUMINE ii SAFETY PLAN DRAFTED BY/QCED BY: THAMIZHARASAN G/MANISH A SCALE:AS NOTED I REV:8 DATE:03/26/2025 I SP -01 ~ M m� O �� t0 d' o, Ln �o O '- ~ UZ U %.0 Z r,, LU Z0N O 74 ? Y vI OoM >°Yoe; 0. O°r4 � N J O V/ Z 0 OO _Ln q* M U LOADING ZONE I N Resolution Number .7,5-13 Date L I R I 1,O -S DATE DESCRIPTION REV 02/29/2024 PERMIT PIAN A ftt/>ri/7f175 TNVFRTFR UPDATE B PROJECT INFORMATION NAME:CURRY HONDA YORKTOWN (COM -41603) ADDRESS:3845 CROMPOND ROAD, YORKTOWN, NY 10598 41.291126,-73.851721 APN: 35.08-1-01 AH1:NY-TOWN OF YORKTOWN UTILITY:CON EDISON PRN NUMBER: FMS -CU -2022-877 :('ILLUMINE ii SAFETY PLAN DRAFTED BY/QCED BY: THAMIZHARASAN G/MANISH A SCALE:AS NOTED I REV:8 DATE:03/26/2025 I SP -01