Loading...
HomeMy WebLinkAbout2026-01-14 - Solar Site Plan 24.75KWDRAWN BY: Customer Information Manuel Pesantes Residence 3611 Gomer St, Yorktown Heights, NY 10598, USA DATE: DG 01/14/2026 DIRECTORY OF PAGES PV - 1 TITLE PAGE PV - 2 SITE PLAN PV - 3 ATTACHMENT PLAN PV - 4 3-LINE DIAGRAM PV - 5 SAFETY LABELS DATASHEETS INVERTER DATASHEET MOUNTING SYSTEM DATASHEET GENERAL NOTE THE SCOPE OF THIS PROJECT INVOLVES THE PLACEMENT OF SOLAR PANELS, WHICH WILL BE SECURED USING A PRE-DESIGNED RACKING SYSTEM. AFTER BEING ARRANGED ON THE RACKS, THE SOLAR MODULES WILL BE JOINED TOGETHER USING DC TO AC POWER INVERTERS, AND THEN LINKED TO THE LOCAL UTILITY THROUGH METHODS THAT COMPLY WITH THE REGULATIONS IMPOSED BY THE UTILITY AND THE JURISDICTION RESPONSIBLE FOR ISSUING PERMITS. SITE LAYOUT INTERCONNECTION DETAILS POINT OF CONNECTION ( AC CONNECTION PER NEC ARTICLE 705.12(D) UTILITY SERVICE 120 / 240 V ELECTRICAL PANEL MAIN SERVICE PANEL W/TOP-FED BUSBAR, MAIN BREAKER SYSTEM DETAILS DESCRIPTION NEW GRID-INTERACTIVE PHOTOVOLTAIC SYSTEM WITH NO BATTERY STORAGE DC RATING OF SYSTEM AC RATING OF SYSTEM INVERTER(S)( ) ENPHASE IQ8MC (240 V) INVERTER TYPE MICRO INVERTER MODULE ( ) PROJECT DETAILS ZONING RESIDENTIAL USE AND OCCUPANCY CLASSIFICATION SINGLE FAMILY DWELLING PERMITTING AUTHORITY UTILITY COMPANY METER SERIAL NUMBER NEC VERSION 2017 NEC (NFPA 70) FIRE CODE 2020 NYS RESIDENTIAL CODE, IBC 2015. Engineering Seal: 13 Trade Zone Drive, Ronkonkoma, NY 11779 Unit #13 PV - 6 PANEL DATASHEET PAGE:1, PROJECT SUMMARY SITE DETAILS ASHRAE EXTREME LOW F ASHRAE 2% HIGH F CLIMATE DATA SOURCE TMY3 WIND SPEED MPH WIND EXPOSURE CATEGORY B GROUND SNOW LOAD PSF 45 45 SEG-550-BMA-BG CONEDISON 200A 200A -7.6° 130 40 24,750 W 14,400 W LINE SIDE 91.4° DRAWN BY: Customer Information Manuel Pesantes Residence 3611 Gomer St, Yorktown Heights, NY 10598, USA DATE: DG 01/14/2026 R324.6 ROOF ACCESS AND PATHWAYS - ROOF ACCESS, PATHWAYS, AND SETBACK REQUIREMENTS SHALL BE PROVIDED IN ACCORDANCE WITH SECTIONS R324.6.1 THROUGH R.324.6.2.1. ACCESS AND MINIMUM SPACING SHALL BE REQUIRED TO PROVIDE EMERGENCY ACCESS TO THE ROOF, TO PROVIDE PATHWAYS TO SPECIFIC AREAS OF THE ROOF, PROVIDE FOR SMOKE VENTILATION OPPORTUNITY AREAS, AND TO PROVIDE EMERGENCY EGRESS FROM THE ROOF. EXCEPTIONS: 1. DETACHED, UNINHABITABLE STRUCTURES, INCLUDING BUT NOT LIMITED TO DETACHED GARAGES, PARKING SHADE STRUCTURES, CARPORTS, SOLAR TRELLISES AND SIMILAR STRUCTURES, SHALL NOT BE REQUIRED TO PROVIDE ROOF ACCESS. 2. ROOF ACCESS, PATHWAYS AND SETBACKS NEED NOT BE PROVIDED WHERE THE BUILDING OFFICIAL HAS DETERMINED THAT ROOFTOP OPERATIONS WILL NOT BE EMPLOYED. 3. THESE REQUIREMENTS SHALL NOT APPLY TO ROOFS WITH SLOPES OF TWO UNITS VERTICAL IN 12 UNITS HORIZONTAL (17-PERCENT SLOPE) OR LESS. (NY) R324.6.1 PATHWAYS - NOT FEWER THAN TWO PATHWAYS, ON SEPARATE ROOF PLANES FROM LOWEST ROOF EDGE TO RIDE AND NOT LESS THAN 36 INCHES (914MM) WIDE, SHALL BE PROVIDED ON ALL BUILDINGS. NOT FEWER THAN ONE PATHWAY SHALL BE PROVIDED ON THE STREET OR DRIVEWAY SIDE OF THE ROOF. FOR EACH ROOF PLANE WITH A PHOTOVOLTAIC ARRAY, A PATHWAY NOT LESS THAN 36 INCHES WIDE (914MM) SHALL BE PROVIDED FROM THE LOWEST ROOF EDGE TO RIDGE ON THE SAME ROOF PLANE AS THE PHOTOVOLTAIC ARRAY, ON AN ADJACENT ROOF PLANE, OR STRADDLING THE SAME AND ADJACENT ROOF PLANES. PATHWAYS SHALL BE OVER AREAS CAPABLE OF SUPPORTING FIRE FIGHTERS ACCESSING THE ROOF. PATHWAYS SHALL BE LOCATED IN AREAS WITH MINIMAL OBSTRUCTIONS SUCH AS VENT PIPES, CONDUIT, OR MECHANICAL EQUIPMENT. PATHWAYS ON OPPOSING ROOF SLOPES SHALL NOT BE LOCATED ALONG THE SAME PLANE AS THE TRUSS, RAFTER, OR OTHER SUCH FRAMING SYSTEM THAT SUPPORTS THE PATHWAY. EXCEPTION: ACCESS PATHWAYS SHALL NOT BE REQUIRED ON ROOF SLOPES CONTAINING PHOTOVOLTAIC MODULES, PANELS, OR AN ARRAY WHERE THE OPPOSING OR ADJACENT ROOF SLOPE IS AN ACCESS ROOF. (NY) R324.6.2 SETBACK AT RIDGE - PHOTOVOLTAIC ARRAYS SHALL NOT BE LOCATED LESS THAN 18 INCHES (457MM) FROM A HORIZONTAL RIDGE. GENERAL NOTES 1 THE CONTRACTOR SHALL USE ONLY COMPONENTS LISTED BY A NATIONALLY RECOGNIZED TESTING LABORATORY FOR THE INTENDED USE. 2 THE CONTRACTOR IS ACCOUNTABLE FOR PROVIDING ALL NECESSARY EQUIPMENT, CABLES, ADDITIONAL CONDUITS, BOXES, RACEWAYS, AND OTHER ACCESSORIES REQUIRED TO ENSURE A FULLY FUNCTIONAL AND OPERATIONAL PV SYSTEM. 3 EQUIPMENT LIKELY TO BE WORKED UPON WHILE ENERGIZED SHALL BE INSTALLED IN LOCATIONS THAT SATISFY MINIMUM WORKING CLEARANCES PER NEC 110.26 4 THE SYSTEM MUST SATISFY THE NEC ARTICLE 690, ADHERE TO ALL MANUFACTURERS' LISTING AND INSTALLATION GUIDELINES, AND COMPLY WITH THE PERTINENT CODES AS STATED BY THE AUTHORITY HAVING JURISDICTION'S (AHJ) RELEVANT REGULATIONS. 5 IF A DC PV SOURCE OR DC PV OUTPUT CIRCUITS ARE ROUTED WITHIN THE BUILDING, THEY MUST BE ENCLOSED IN METAL RACEWAYS, TYPE MC METAL-CLAD CABLE, OR METAL ENCLOSURES FROM THE POINT OF ENTRY INTO THE BUILDING UP TO THE INITIAL DISCONNECTING MECHANISM READILY ACCESSIBLE, AS PER NEC 690.31(G). Engineering Seal: 13 Trade Zone Drive, Ronkonkoma, NY 11779 Unit #13 SCALE 1/32" = 1'-0 PAGE:2, SITE PLAN FR O N T O F H O U S E , F A C I N G S T R E E T MICRO INVERTERS UNDER MODULES (45) PV ARRAY GROUND MOUNT SYSTEM FACING SOUTH MAIN HOUSE D M D UTILITY METER MAIN SERVICE PANEL PV AC COMBINER BOX W MONITORING AC DISCONNECT AC DISCONNECT ± 28'-7'' TRENCHED CONDUIT TRENCHED/OVEHEAD G O M E R S T POOL EXISTING PROPERTY LINE NEIGHBOUR HOUSE NEIGHBOUR HOUSE DRAWN BY: Customer Information Manuel Pesantes Residence 3611 Gomer St, Yorktown Heights, NY 10598, USA DATE: DG 01/14/2026 NOTE ·AN 18" WIDE CLEARING (FREE OF SOLAR EQUIPMENT) SHALL BE PROVIDED ALONG AT LEAST ONE SIDE OF THE ROOF RIDGE ON THE SAME SIDE AS THE SOLAR EQUIPMENT OR ON ANOTHER SIDE OF THE RIDGE THAT DOES NOT HAVE SOLAR EQUIPMENT ON IT. SUFFICIENT ACCESS PATHWAYS, ROOF ACCESS POINTS, AND GROUND ACCESS AREAS SHALL BE PROVIDED IN ACCORDANCE WITH THE 2020 NYS RESIDENTIAL CODE. ·ROOF SHALL HAVE NO MORE THAN A SINGLE LAYER OF ROOF COVERING IN ADDITION TO THE SOLAR EQUIPMENT. ·INSTALLATION OF SOLAR EQUIPMENT SHALL BE FLUSH-MOUNTED, PARALLEL TO AND NO MORE THAN 6-INCHES ABOVE THE SURFACE OF THE ROOF. ·WEIGHT OF THE INSTALLED SYSTEM SHALL NOT EXCEED MORE THAN 5-PSF. ·ANY PLUMBING VENTS ARE NOT TO BE CUT OR COVERED FOR SOLAR EQUIPMENT INSTALLATION. ANY RELOCATION OR MODIFICATION OF THE VENT REQUIRES A PLUMBING PERMIT AND INSPECTION. THIS PV SYSTEM HAS BEEN DESIGNED TO MEET THE MINIMUM DESIGN STANDARDS FOR BUILDING AND OTHER STRUCTURES OF THE ASCE 7-16, 2020 NYS RESIDENTIAL CODE. Engineering Seal: 13 Trade Zone Drive, Ronkonkoma, NY 11779 Unit #13 SCALE 3/32" = 1'-0 PAGE:3, ATTACHMENT PLAN "RAIL END OVERHANG" DISTANCE FROM RAIL END TO OUTER ROOF ATTACHMENT CENTER. NOT TO EXCEED 34% OF ALLOWABLE SPAN STRUCTURAL MEMBER "RAIL SPAN" DISTANCE BETWEEN CENTERS OF TWO ROOF ATTACHMENTS BA PV MODULE, TYP. C MID CLAMP ASSEMBLY SS BONDING PIN MODULE FRAME RAIL CHANNEL NUT 6-12 AWG BARE COPPER WIRE 5/16"-18 SS BOLT SS SPLIT LOCK WASHER (TORQUE TO 16 FT-LBS) SNAPNRACK GROUND LUG CHANNEL NUT RAIL SS BONDING PINS ARRAY1 180° TRUE; 30° TILT; 7/12 PITCH (45) MODULES 1/2" SPACING BETWEEN ROWS AND COLUMNS DRAWN BY: Customer Information Manuel Pesantes Residence 3611 Gomer St, Yorktown Heights, NY 10598, USA DATE: DG 01/14/2026 Engineering Seal: 13 Trade Zone Drive, Ronkonkoma, NY 11779 Unit #13 PAGE:3, ATTACHMENT PLAN DRAWN BY: Customer Information Manuel Pesantes Residence 3611 Gomer St, Yorktown Heights, NY 10598, USA DATE: DG 01/14/2026 Engineering Seal: 13 Trade Zone Drive, Ronkonkoma, NY 11779 Unit #13 PAGE:4, LINE DIAGRAM GENERAL NOTES 1 ALL MODULES WILL BE GROUNDED IN ACCORDANCE WITH CODE AND THE MANUFACTURER'S INSTALLATION INSTRUCTIONS 2 ALL PV EQUIPMENT SHALL LISTED BY RECOGNIZED TESTING LAB 3 WHEN A BACKFEED BREAKER IS METHOD OF UTILITY INTERCONNECTION, BREAKER SHALL NOT READ LINE AND LOAD 4 WHEN A BACKFEED BREAKER IS METHOD OF UTILITY INTERCONNECTION, THE BREAKER SHALL BE INSTALLED AT THE OPPOSITE END OF THE BASS BAR OF THE MAIN BREAKER 5 WORK CLEARANCE AROUND ELECTRICAL EQUIPMENT WILL BE MAINTAINED PER NEC 110.26(A)(1), 110.26(A)(2), 110.269(A)(3) 6 ALL EXTERIOR CONDUITS, FITTINGS AND BOXES SHALL BE RAIN TIGH AND BE MIN. NEMA 3R RATED 7 AC AND DC GROUNDING CONDUCTORS PER NEX ARTICLE 690.43(A) THRU (F) CONNECTED AS PER 690.45(A), 690.46 AND SIZED PER 250.112 8 PROVIDE EXPANSION JOINTS AND ANCHORING OF ALL CONDUIT RUNS AS PER NEC REQUIREMENTS 9 PROVIDE LABEL, PLACARD AT EXISTING UTILITY CONNECTION WITH "WARNING - CUSTOMER OWNED ELECTRICAL GENERATION EQUIPMENT CONNECTED" WITH APPROPRIATE HAZARD AND OUTPUT RAITING OF PV SYSTEM 15A/2P N L2 L1 IQ COMBINER PANEL ENPHASE ENVOY 20A/2P EGC ATTACHED TO RAIL 1 2 ATTICROOF SOLAR DECK 1 2 20A/2P 100A RATED AC DISCONNECT 80A RATED FUSES 98 7 EXTERIOR WALL 20A/2P 1 2 EGC ATTACHED TO RAIL 3 4 ATTICROOF SOLAR DECK 1 2 20A/2P 5 6 ATTICROOF SOLAR DECK12 20A/2P EGC ATTACHED TO RAIL NUMBER OF CONDUC TORS CONDUCT SIZE ENPHASE Q-CABLE 12 4 N/A N/A 100'-0" BARE COPPER GND IN FREE AIR 6 1 N/A N/A 35'-0" 2 THHN 10 4 LFMC & PVC 1"40'-0" 3 ENPHASE Q-CABLE 12 4 PVC SCH. 40 1"100'-0" BARE COPPER GND IN FREE AIR 6 1 PVC SCH. 40 1"35'-0" 4 THHN 10 4 LFMC & PVC 1"40'-0" 5 ENPHASE Q-CABLE 12 2 PVC SCH. 40 1"100'-0" BARE COPPER GND IN FREE AIR 6 1 PVC SCH. 40 1"35'-0" 6 THHN 10 2 LFMC & PVC 1"40'-0" 7 THHN 10 10 PVC SCH. 40 1"25'-0" EGC 10 2 PVC SCH. 40 1"25'-0" 8 THHN 4 3 PVC SCH. 40 1"20'-0" EGC 4 1 PVC SCH. 40 1"20'-0" 9 THHN 4 3 PVC SCH. 40 1"20'-0" GEC 4 1 RMC 1"20'-0" 1 2 MAIN LOADS NOTE: THIS MAIN DISTRIBUTION PANEL HAS A RATED BUS WITH MAIN BREAKER BUS x 120% = - MAIN = THE MAXIMUM BACK FEED CIRCUIT BREAKER SIZE IS PER NEC 2017 SECTION 705.12(D)(2)(3)(b) CONNECTION WITH LINE SIDE TAP PER NEC 2017 SECTION 230.82(6) LINE SIDE TAP 200A 200A200A 200A 240 A 240 A 200A 40 A 40 A STRING OF (9) (9) ENPHASE IQ8MC-72-M-US MICRO INVERTER IN PARALLEL 9 MODULES/STRING x 1.33 A/MODULE = 11.97 AMP LOAD/STRING 11.97 AMP x 1.25 CONT DUTY = 14.96 AMP (WIRE AMPACITY MIN.) 98 SEG-550-BMA-BG STRING OF (9) (9) ENPHASE IQ8MC-72-M-US MICRO INVERTER IN PARALLEL 9 MODULES/STRING x 1.33 A/MODULE = 11.97 AMP LOAD/STRING 11.97 AMP x 1.25 CONT DUTY = 14.96 AMP (WIRE AMPACITY MIN.) 98 SEG-550-BMA-BG STRING OF (9) (9) ENPHASE IQ8MC-72-M-US MICRO INVERTER IN PARALLEL 9 MODULES/STRING x 1.33 A/MODULE = 11.97 AMP LOAD/STRING 11.97 AMP x 1.25 CONT DUTY = 14.96 AMP (WIRE AMPACITY MIN.) 98 SEG-550-BMA-BG STRING OF (9) (9) ENPHASE IQ8MC-72-M-US MICRO INVERTER IN PARALLEL 9 MODULES/STRING x 1.33 A/MODULE = 11.97 AMP LOAD/STRING 11.97 AMP x 1.25 CONT DUTY = 14.96 AMP (WIRE AMPACITY MIN.) 98 SEG-550-BMA-BG STRING OF (9) (9) ENPHASE IQ8MC-72-M-US MICRO INVERTER IN PARALLEL 9 MODULES/STRING x 1.33 A/MODULE = 11.97 AMP LOAD/STRING 11.97 AMP x 1.25 CONT DUTY = 14.96 AMP (WIRE AMPACITY MIN.) 98 SEG-550-BMA-BG DRAWN BY: Customer Information Manuel Pesantes Residence 3611 Gomer St, Yorktown Heights, NY 10598, USA DATE: DG 01/14/2026 Engineering Seal: 13 Trade Zone Drive, Ronkonkoma, NY 11779 Unit #13 PAGE:4, LINE DIAGRAM GENERAL NOTES 1 ALL MODULES WILL BE GROUNDED IN ACCORDANCE WITH CODE AND THE MANUFACTURER'S INSTALLATION INSTRUCTIONS 2 ALL PV EQUIPMENT SHALL LISTED BY RECOGNIZED TESTING LAB 3 WHEN A BACKFEED BREAKER IS METHOD OF UTILITY INTERCONNECTION, BREAKER SHALL NOT READ LINE AND LOAD 4 WHEN A BACKFEED BREAKER IS METHOD OF UTILITY INTERCONNECTION, THE BREAKER SHALL BE INSTALLED AT THE OPPOSITE END OF THE BASS BAR OF THE MAIN BREAKER 5 WORK CLEARANCE AROUND ELECTRICAL EQUIPMENT WILL BE MAINTAINED PER NEC 110.26(A)(1), 110.26(A)(2), 110.269(A)(3) 6 ALL EXTERIOR CONDUITS, FITTINGS AND BOXES SHALL BE RAIN TIGH AND BE MIN. NEMA 3R RATED 7 AC AND DC GROUNDING CONDUCTORS PER NEX ARTICLE 690.43(A) THRU (F) CONNECTED AS PER 690.45(A), 690.46 AND SIZED PER 250.112 8 PROVIDE EXPANSION JOINTS AND ANCHORING OF ALL CONDUIT RUNS AS PER NEC REQUIREMENTS 9 PROVIDE LABEL, PLACARD AT EXISTING UTILITY CONNECTION WITH "WARNING - CUSTOMER OWNED ELECTRICAL GENERATION EQUIPMENT CONNECTED" WITH APPROPRIATE HAZARD AND OUTPUT RAITING OF PV SYSTEM IQ COMBINER PANEL 100A RATED AC DISCONNECT 80A RATED FUSESSOLAR DECK 1 2 ATTICROOF 54 NUMBER OF CONDUC TORS CONDUCT SIZE ENPHASE Q-CABLE 12 4 N/A N/A 100'-0" BARE COPPER GND IN FREE AIR 6 1 N/A N/A 35'-0" 2 THHN 10 4 LFMC & PVC 1"40'-0" 3 ENPHASE Q-CABLE 12 4 PVC SCH. 40 1"100'-0" BARE COPPER GND IN FREE AIR 6 1 PVC SCH. 40 1"35'-0" 4 THHN 10 4 LFMC & PVC 1"40'-0" 5 ENPHASE Q-CABLE 12 2 PVC SCH. 40 1"100'-0" BARE COPPER GND IN FREE AIR 6 1 PVC SCH. 40 1"35'-0" 6 THHN 10 2 LFMC & PVC 1"40'-0" 7 THHN 10 10 PVC SCH. 40 1"25'-0" EGC 10 2 PVC SCH. 40 1"25'-0" 8 THHN 4 3 PVC SCH. 40 1"20'-0" EGC 4 1 PVC SCH. 40 1"20'-0" 9 THHN 4 3 PVC SCH. 40 1"20'-0" GEC 4 1 RMC 1"20'-0" MSP BUSBAR 200A 200A DC AC 24,750 W 14,400 W STRING OF (9) (9) ENPHASE IQ8MC-72-2-US MICRO INVERTER IN PARALLEL SEG-550-BMA-BG STRING OF (9) (9) ENPHASE IQ8MC-72-2-US MICRO INVERTER IN PARALLEL SEG-550-BMA-BG STRING OF (9) (9) ENPHASE IQ8MC-72-2-US MICRO INVERTER IN PARALLEL SEG-550-BMA-BG STRING OF (9) (9) ENPHASE IQ8MC-72-2-US MICRO INVERTER IN PARALLEL SEG-550-BMA-BG STRING OF (9) (9) ENPHASE IQ8MC-72-2-US MICRO INVERTER IN PARALLEL SEG-550-BMA-BG DRAWN BY: Customer Information Manuel Pesantes Residence 3611 Gomer St, Yorktown Heights, NY 10598, USA DATE: DG 01/14/2026 1 NEC ARTICLE 690.31(G)(3) 2 AT THE EACH DISCONNECTING MEANS FOR PHOTOVOLTAIC EQUIPMENT. NEC ARTICLE 690.17(4) 3 AT EACH DEVICE WHERE ENERGIZED, UNGROUNDED CIRCUITS MAY BE EXPOSED DURING SERVICE. NEC ARTICLE 690.35(F) 4 DC DISCONNECT, NEC ARTICLE 690.53 (FOR REFERENCE ONLY) 5 AC DISCONNECT, NEC ARTICLE 690.54 (FOR REFERENCE ONLY) 6 NEC ARTICLE 690.56(C) 7 SOLAR BREAKER (MSP) NEC ARTICLE 705.12(D)(2)(3)(B) 8 ANY AC ELECTRICAL PANEL THAT IS FEED BY BOTH THE UTILITY AND THE PHOTOVOLTAIC SYSTEM (MSP) NEC ARTICLE 705.12(D)(4) Engineering Seal: 13 Trade Zone Drive, Ronkonkoma, NY 11779 Unit #13 9 PLACED ON ALL INTERIOR AND EXTERIOR DC CONDUIT, RACEWAYS, ENCLOSURES, AND CABLE ASSEMBLIES AT LEAST EVERY 10 FEET IFC603.11.1.4 LABELING NOTES 1 ALL PLAQUES AND SIGNAGE REQUIRED BY 2017 NEC WILL BE INSTALLED AS REQUIRED 2 IT IS REQUIRED TO PLACE WARNING LABELS ON EACH DC RACEWAY EVERY 10 FEET, AS WELL AS WITHIN ONE FOOT OF EVERY TURN OR BEND, AND ONE FOOT ABOVE AND BELOW ANY PENETRATION OF ROOF/CEILING ASSEMBLIES, WALLS, OR BARRIERS. THESE LABELS MUST CONTAIN THE MARKING "WARNING: PHOTOVOLTAIC POWER SOURCE" AND HAVE 3/8" TALL LETTERS. THE LABEL MUST BE REFLECTIVE WITH WHITE TEXT ON A RED BACKGROUND. 3 A PERMANENT PLAQUE OR DIRECTORY MUST BE INSTALLED TO INDICATE THE LOCATION OF THE SERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM DISCONNECTING MEANS, IF THEY ARE NOT IN THE SAME LOCATION. THIS IS TO ENSURE COMPLIANCE WITH NEC 690.56(B). 4 LABEL(S) WITH MARKING "SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN." SHALL BE LOCATED POINT-OF-INTERCONNECTION OR AT MAIN SERVICE DISCONNECT. THE LABEL SHALL HAVE 3/8" TALL LETTERS AND BE REFLECTIVE WITH WHITE TEXT ON A RED BACKGROUND 5 IF THE INVERTERS ARE REMOTELY LOCATED FROM ONE ANOTHER, DIRECTORIES MUST BE INSTALLED AT EACH DC PHOTOVOLTAIC SYSTEM DISCONNECTING MEANS, AC IS CONNECTING MEANS, AND MAIN SERVICE DISCONNECTING MEANS. THESE DIRECTORIES MUST SHOW THE LOCATION OF ALL AC AND DC PHOTOVOLTAIC SYSTEM DISCONNECTING MEANS IN THE BUILDING, IN ACCORDANCE WITH NEC 690.4(H). 6 ALL LABELS, WARNINGS, AND MARKINGS MUST FOLLOW ANSI Z535.4 REGULATIONS. THIS REQUIRES THE USE OF DANGER, WARNING, AND CAUTION SIGNS WITH STANDARD HEADER COLORS, HEADER TEXT, AND SAFETY ALERT SYMBOL ON EACH LABEL. THE ANSI STANDARD ALSO DEMANDS A HEADING THAT IS AT LEAST 50% TALLER THAN THE BODY TEXT, AS SPECIFIED BY NEC ARTICLE 110.21(B) i. 7 THE MATERIALS USED FOR MARKING MUST BE WEATHER RESISTANT, IN COMPLIANCE WITH CBC 511.3.1. IT IS RECOMMENDED THAT UL 969 BE USED AS STANDARD TO DETERMINE WEATHER RATING PAGE:5, SAFETY LABELS DRAWN BY: Customer Information Manuel Pesantes Residence 3611 Gomer St, Yorktown Heights, NY 10598, USA DATE: DG 01/14/2026 Engineering Seal: 13 Trade Zone Drive, Ronkonkoma, NY 11779 Unit #13 PAGE:6, DATASHEETS DRAWN BY: Customer Information Manuel Pesantes Residence 3611 Gomer St, Yorktown Heights, NY 10598, USA DATE: DG 01/14/2026 Engineering Seal: 13 Trade Zone Drive, Ronkonkoma, NY 11779 Unit #13 PAGE:6, DATASHEETS DRAWN BY: Customer Information Manuel Pesantes Residence 3611 Gomer St, Yorktown Heights, NY 10598, USA DATE: DG 01/14/2026 Engineering Seal: 13 Trade Zone Drive, Ronkonkoma, NY 11779 Unit #13 PAGE:6, DATASHEETS DRAWN BY: Customer Information Manuel Pesantes Residence 3611 Gomer St, Yorktown Heights, NY 10598, USA DATE: DG 01/14/2026 Engineering Seal: 13 Trade Zone Drive, Ronkonkoma, NY 11779 Unit #13 PAGE:6, DATASHEETS