HomeMy WebLinkAbout15_Hazardous MaterialsDRAFT 15-1 07/10/2024
Chapter 15: Hazardous Materials
A. INTRODUCTION AND SUMMARY OF FINDINGS
This chapter assesses the potential for increased exposure to environmental contamination or
hazardous materials during construction and operation of the Proposed Project, and the specific
measures that would be employed to protect public health, worker safety, and the environment. A
hazardous material is generally defined as any substance which is listed, defined, or regulated as
hazardous or toxic by or under any law pertaining to human health, safety and/or the environment.
To assess the potential presence of hazardous materials on the Project Site, a Phase I
Environmental Site Assessment (ESA) was reviewed. The ESA does not identify any recognized
environmental conditions (RECs) in connection with the Project Site.
No significant adverse impacts related to hazardous materials would be expected to occur as a
result of the Proposed Project and, as such, no mitigation measures would be required.
B. EXISTING CONDITIONS
The ESA of the Project Site was performed by William Silveri, LLC (WVS) on April 11, 2022
(see Appendix H). It was performed in conformance with the scope and limitations of ASTM
International (ASTM) Standard Practice E1527-21. Additionally, on August 23, 2023, AKRF, Inc.
performed an on-site assessment to confirm the findings of the ESA and existing site conditions.
PHASE I ENVIRONMENTAL SITE ASSESSMENT
The ESA was conducted to identify RECs and any other environmental concerns
associated with the Project Site resulting from past or current Project Site usage and usage
of neighboring properties. RECs are defined in ASTM as the presence or likely presence
of any hazardous substances or petroleum products in, on, or at a property (1) due to any
release to the environment; (2) under conditions indicative of a release to the environment;
or (3) under conditions that pose a material threat of a future release to the environment.
The Standard Practice also defines de minimis conditions, which are conditions that
generally do not present a threat to human health or the environment and that generally
would not be the subject of an enforcement action if brought to the attention of appropriate
governmental agencies.
The ESA does not identify any RECs at the Project Site; however, the following de
minimis conditions and business environmental risk were identified:
De Minimis Conditions
Historic aerial photographs indicate an orchard or other agricultural use between
1941 and 1954. The ESA indicates that this past use may have included the
application of herbicides and pesticides. However, the area is limited and not well
defined on the aerial photographs. Additionally, there is no definitive
800 East Main Street Redevelopment
07/10/2024 15-2 DRAFT
confirmation that herbicides and pesticides were historically used at the Project
Site, based on a review of files maintained by the Town of Yorktown municipal
offices. The potential extent and impacts of historic usage of herbicides and
pesticides is a de minimis condition because the former agricultural use appears
to affect only limited areas of the Project Site and limited information is available
pertaining to their use at the Project Site.
Business Environmental Risk
There is one (1) 2,500-gallon No. 2 fuel oil underground storage tank (UST), one
(1) 2,000-gallon UST at the Project Site and one (1) 1,000-gallon UST at the
Project Site. They are considered to be a business environmental risk. The ESA
concludes that they are unlikely to have caused a significant release due to their
age and date of operation, their design, and their oversight by the building
maintenance staff. The USTs were installed in 2005 and 2017 and designed to
comply with petroleum storage regulations enacted to prevent or minimize
petroleum spills/releases. The design of each UST is double-walled steel
construction with fiberglass coating to prevent corrosion. The tanks also have
interstitial leak-detection monitoring systems (i.e., leak detection between the
double walls of the UST) for identifying a release prior to it impacting the
environment. Additionally, the USTs and their leak detection systems are
regularly inspected by building maintenance staff.
Based on the findings, WVS recommended the following:
No further testing was warranted to evaluate subsurface conditions at the
Property.
The USTs will need to be removed at the time that they are taken out-of-
service and will require soil sampling at each UST excavation in accordance
with applicable local, state, and federal regulations.
Although the existing buildings on the Project Site were constructed after
1989 (after the use of asbestos had been banned in many of its application),
there is a potential for some asbestos containing building materials (ACM).
For this reason, an asbestos survey should be conducted prior to any building
demolition or renovation work.
Any excess excavated soils and/or demolition debris generated by future
development activities will need to be properly characterized for off-site
disposal in accordance with applicable local and state solid waste regulations.
CONFIRMATION ASSESSMENT
In August 2023, AKRF completed an assessment to confirm the findings of the ESA. The
August 2023 assessment was conducted using ASTM methodology consistent with the
requirements of a Phase I environmental site assessment, and included: an inspection of
the Project Site; reconnaissance of the vicinity; interviews with the Project Site facilities
manager; a review of historic fire insurance (Sanborn) maps and Town directories; a
review of aerial photographs and historical topographic maps, historical resources, and
the ESA; a review of regulatory databases, including NYSDEC and U.S. Environmental
Protection Agency (“EPA”) records; a review of available files maintained by the Town
of Yorktown Tax Assessor, Town Building Department, and Town Fire Marshal; and a
Chapter 15 Hazardous Materials
DRAFT 15-3 07/10/2024
review of the WCDOH records and the updated Petroleum Bulk Storage registration
certificate.
AKRF confirmed each of the findings of the ESA but identified the following de minimis
conditions:
Although the USTs and two 50-gallon above-ground storage tanks (ASTs) at the
Project Site would typically be considered a REC, based on the age of the tanks, their
date of operation, their design, and because the USTs and their leak detection systems
are regularly inspected by building maintenance staff, AKRF considers the USTs and
ASTs to be a de minimis condition.
On October 11, 2011, a tank tightness failed on the 2,000-gallon UST, and a spill was
reported to NYSDEC (Spill No. 1108736). According to the report, the tank was
retested after its fill and vent pipes and associated fittings were replaced and passed
the second tightness test. Based on the corrective action and results of the second tank
tightness test, the NYSDEC closed the spill on November 7, 2011. In September 2017,
American Petroleum Equipment & Construction Company, Inc. oversaw the
excavation and removal of the 2,000-gallon fuel oil UST. After removal of the tank
from the ground, soil along the bottom and sidewalls of the tank excavation were field
screened for the presence of volatile organic compounds (VOCs) utilizing a
photoionization detector. The field screening found no presence of VOCs in the soils.
Additionally, the UST was observed to be in good condition, with no pitting or holes.
Confirmatory end point samples were collected from the tank grave and submitted for
laboratory analysis for VOCs and semi-volatile organic compounds (SVOCs). No
detectable concentrations of VOCs or SVOCs were found in the end-point soils
samples. Based on the details of the closed spill and the tank closure report, AKRF
considers the former 2,000-gallon fuel oil UST a de minimis condition.
It should be noted that the scope of AKRF’s August 2023 confirmation assessment did
not include surface water, soil, soil vapor, or groundwater sampling. Consequently,
conclusions provided regarding impacts are limited to those based solely on a non-
intrusive investigation.
UPDATED WCDOH PETROLEUM BULK STORAGE REGISTRY
The WCDOH provided a copy of the current Petroleum Bulk Storage Registration
Certificate for the Project Site under no. 3-601248. According to the Certificate, the
Project Site utilizes the following in-service No. 2 fuel oil tanks: one 2,500-gallon UST
installed in 12/2005; one 1,000-gallon UST installed in 12/2005; two 50-gallon ASTs
installed in 03/2006; and one 2,000-gallon UST installed in 09/2017.
POTENTIAL OF BUILDINGS TO CONTAIN HAZARDOUS MATERIALS
On June 2, 2022, GLS Inspection LLC of Fairlawn, New Jersey performed a
comprehensive pre-demolition asbestos containing materials (ACM) survey in Buildings
1 and 2 and the associated auxiliary structures at the Project Site.
Guidelines used for the inspection were established by the Environmental Protection
Agency (EPA) – Asbestos Hazard Emergency Response Act (AHERA) 40 CFR Part 763.
An AHERA like inspection was done in accordance with “Asbestos Survey Planning and
Design” Subpart 56-5 of the New York State Industrial Code Rule 56 Title 12, March 21,
2007, and New York City Department of Environmental Protection (DEP) Asbestos Rules
800 East Main Street Redevelopment
07/10/2024 15-4 DRAFT
and Regulations Title 15, Chapter 1, February 3, 2011. Bulk samples of suspect ACM
were analyzed using polarized light microscopy (PLM) Stratified Point Counting Method.
This method can be found as item 198.1 in the Environmental Laboratory Approval
Program (ELAP) Certification manual and is required for samples collected in New York
State. New York State regulation defines an ACM as containing greater than 1percent
asbestos. If Non-friable Organically Bound (NOB) bulk sample results are negative
(containing 1 percent asbestos or below), New York State requires that those samples be
analyzed by Transmission Electron Microscopy (TEM) method to confirm the result.
The results of the GLS’s ACM survey were presented in their June 2022 Non-ACM
Report (See Appendix H). Based on the ACM bulk sample analytical results, GLS
concluded that no positive ACMs were found on the interior or exterior portions of the
Project Site.
Since the current buildings on the Project Site were developed after the use of lead based
paint (LBP) was banned in 1978, the presence of LBP is unlikely and was not tested.
C. THE FUTURE WITHOUT THE PROPOSED PROJECT
In the future without the Proposed Project, the Project Site and current environmental conditions
would remain unchanged.
The potential for on-site hazardous materials to have a significant adverse impact on either users
of the Project Site or neighboring properties would remain low. Although potential adverse
environmental impacts are possible with the active USTs and ASTs, the USTs and ASTs would
continue to be managed in accordance with applicable NYSDEC and WCDOH regulations,
including regular inspection and testing, to minimize any potential adverse environmental impact.
D. THE FUTURE WITH THE PROPOSED PROJECT
Redevelopment of the Project Site would involve demolition of the Project Site buildings and
improvements. The greatest potential for exposure to contaminated materials would occur during
demolition and excavation.
Prior to Project Site redevelopment, the USTs and ASTs would be taken out of service and
removed in accordance with the prevailing regulations and requirements, the registration
would be closed with NYSDEC and/or the WCDOH, and any contaminated soil (if
encountered) would be addressed in accordance with applicable regulations.
Any soil or fill excavated as part of future Site redevelopment activities would be managed in
accordance with applicable regulations. All material intended for off-site disposal would be
tested in accordance with the requirements of the intended receiving facility. Transportation
of all soil leaving for off-site disposal would be in accordance with requirements covering
licensing of haulers and trucks, placarding, truck routes, manifesting, etc. Intrusive sampling
was not conducted as part of the ESA or the August 2023 confirmation assessment. Excavation
may reveal different or more significant soil contamination in areas not reviewed as part of
the assessments. If discovered, such contamination could require further investigation and/or
remediation in accordance with applicable regulations.
If any additional or previously unknown USTs and/or petroleum contaminated soil are
encountered during the development activities, the tanks would be closed in accordance with
Chapter 15 Hazardous Materials
DRAFT 15-5 07/10/2024
applicable NYSDEC and WCDOH regulations, and any contaminated soil would be properly
removed.
GLS Inspection LLC of Fairlawn, New Jersey performed a comprehensive pre-demolition
ACM survey in the Project Site buildings and associated auxiliary structures in June 2022,
which indicated that no ACMs were present. If any additional suspect ACMs are encountered
during demolition that were not previously identified by GLS or AKRF during the Phase I
ESA, the material should be sampled in accordance with applicable regulations. If any of the
tested materials are positive for ACM (greater than 1 percent asbestos), they should be
removed prior to demolition by a licensed asbestos abatement contractor in accordance with
applicable regulatory requirements.
Demolition activities with the potential to disturb LBP would be performed in accordance
with the applicable Occupational Safety and Health Administration regulation (OSHA 29 CFR
1926.62—Lead Exposure in Construction).
If dewatering is required, treatment and discharge of dewatering fluids would be conducted in
accordance with all applicable regulations and guidance, including obtaining appropriate permits.
Appropriate erosion and sediment controls would be implemented in accordance with
NYSDEC Stormwater Pollution Prevention Plan requirements.
E. MITIGATION MEASURES
As the ESA and the confirmation assessment revealed no evidence of RECs in connection with
the Project Site, no mitigation measures are required. It is recommended that a Soil Management
Plan be prepared prior to site demolition and grading activities to establish measures to address
removal and closure of the on-site USTs and ASTs and any previously unknown tanks (if
encountered), petroleum contamination, and/or residual contamination (if encountered) during
redevelopment, and also to identify procedures for testing and handling any soil intended for off-
site disposal. In addition, the measures described above would be implemented to avoid and
mitigate potential adverse impacts.